Get complete information related to latest Cooling Blower Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cooling Blower Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cooling Blower Tenders.
Tender For supply of electric slaughterhouse (for animals) - primary & secondary chamber primary chamber* single chmber furnace of size 4270 mm x 1980 mm x 1820 mm.* plate thickness- 5 to 8 mm.* lining of interior of furnace- 400 mm wall cermaic blanketk, high aluminia refractory brick is-8-1994 line with insulation brick is 2042-2006* operation temperature- 800o c to 1000o c.* top smoke discharge for secondary chamber.* ash removal doors to be provided for ash collection after combustion.* ingtion- automatic.* temperature control- automatic* material loading- front gate- automaticsecondary chamber* operating temperature - 1050o c to 1250o c.* material of construction- mild steel with high aluminia refractory brick is-8-1994 line with insulation brick is 2042-2006.* made from is 2062 grade mild steel materials (or better) duty lined with insulation bricks, refractory bricks, hysil boards.* burner mounting arrangement with refractory burner block.furnace door:furnace door charging & discharging side fabricated from 5mm to 6 mm thickness door opening & closing automatic.ash door:* ash door (with casted cement lining) to remove nonhazardous ash from the chamber.* top inlet bottom smoke discharge for longer gas residence time.* furnace door charging & discharging side fabricated from 5mm to 6 mm thickness.* door opening & closing automatic/manual.refractory:{complete set of refractory shaped bricks for construction electric cremation of i.s. 8 bricks (approx. 1007nos bricks,insulation 4000 nos. refractory slid for construction of flue duct , as required, refractory heat resistant fire clay , ceramic blanket hysil board, asbestos ropes etc. as required for outer side of the furnace shall be constructed by red bricks by sand and cement as mortars and construction of chimney from basement of roof level including painting i.e. bricks portion shall be painted by two coats of red oxide as primer and to coats of synthetic enamel. (a) complete lining & assembling of entire cremation chamber according to standard size with proper arrangement of accommodation of heating elements, resting of dead body with sufficient opening for falling of ashes to the ash chamber & sufficient ventilation for fresh air spraying. (b) complete lining and assembling of entire cremation chamber according to standard size with provision of drawing out aces from the rear side and sufficient ventilation for fresh air injection. complete lining and assembling of entire cremation chamber according to the standard size with provision of air inlet supplying by fresh air blower and arrangement of multi ventilation path for fresh air}. osspl make, thermocouple heat sensor supply & fixing the thermocouple of heat sensing range 0 - 1200 c (cr.-al) sensor housed in s.s 304 casing of dimension 1200 mm long 22 mm od complete encased to and fitted terminal on other and for connection of compensating of 2 cores 0.5 aq. mm cr- al for heat sensing from thermocouple to temperature controller covered with asbestos embedded rope about 50 m length as per direction of eic., f.d. fan/centrifugal air blower with electric motor * supply and delivery at site, installation, testing and commissioing.* of fresh air injection system forced draft fan mild steel.* type: centrifugal.* capacity:- 500 cmh.* pressure:- 220 mmwg.* motor rating:- 2hp (kirloskar/crompton), burner assembly * total 2 nos. of lpg/cng/png fired automatic burner required.* the burner should be provided with comprising diffuser plate/ burner plate, photo cell housing electrodes with holding brackets, solenoid valve, electrodes caps, flexible hose pipes, spary nozzles, oil filter, blower, etc. connected with electric motor (each burner) & in built air regulator.* burners will work on auto on/off as per the set temperature for the combustion chambers.* the in-built bolwer will provide continuous air flow to the burners to prevent demages due to high temperature., supply and fixing of manifold with a p
Tender For corrigendum : supply installation of laboratory wet shaking mineral separation table - shifting and repairing of fumehood by thoroughly opening, checking, and fixing, also, it will include the change of pulley lock and ss rope. the work will include appropriate ducting of the fumehoods during reinstallation., shifting, thoroughly opening, cleaning, fitting, and fixing of the chemical cabinet, along with ducting associated with it during reinstallation., shifting and repairing of a lab bench with a granite top (size 10 ft x 3 ft) and fitting with drawers and cabinets below the lab bench.it must include granite cutting and setting with adjustable nut bolt., water basin repairing, reinstallation, andfitting and fixing with nuts/ bolts, with appropriate clamps, door lockhinge with a bottom portion having a storage rack., installation of the air exhaust motor 440v, along with the pipeline, by opening and re-fixing. it will include blower motor repairing and ball bearing changing., reestablishment of electric connection for fumehoods in the new lab, blower motor cable, and starting relay control board. installation of switch lamps for the fumeoods., air pressure monitor repairing and servicing for the fume hoods.adaptor sensor data cable complete fitting and fixing., complete painting of fume hoods.inner & outer, chemical storage and lab bench, as well as a wash basin.
Tender For supply of rubber gasket having a length of 3.5 mtr each nos. for oil coolingblower (ocb) dome as per ref.10 of clw drg.no. clw/es/3/sk-6/0023 alt-h [ warranty period: 30 months after the date of delivery ]
Tender For supply of non-driving side end shield for oil coolingblower along with inner and outer grease cups suitable for 6312 ball bearing make m/s stesalit. [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of spare impeller for tm coolingblower (mvmt) to clws spec no.clw/es/b-14 alt-c or latest. [ warranty period: 30 months after the date of delivery ]