Get complete information related to latest Copper Anode Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Copper Anode Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Copper Anode Tenders.
Tender For supply of vacuum components as per attached list d d - cf200_35 ss304 zero length flange , cf150_35 ss304 zero length flange , cf100_35 ss304 zero length flange , cf100 ss304 viewport , cf63 ss304 viewport , cf35 ss304 bellow adapter having bellow id 25mm and total length 75mm , cf35 ss304 bellow adapter having bellow id 25mm and total length 100mm , cf100 ss304 bellow adapter with tie rods having bellow id 100mm and total length 150mm , cf35 ss304 flange having 1 by 2 inch od pipe welded , cf35 ss304 flange having 1 by 4 inch od pipe welded , cf 150 ss304 customized multi_port chamber , cf200_150 ss304 conical reducer , kf16 manually operated bellow sealed right angle valve_ss304 body , kf25 manually operated bellow sealed right angle valve _ss304 body , cf35 bellow sealed manually operated linear drive with 50mm travel , kf25 ss304 flexible hose having total length 1mtr , kf25 ss304 flexible hose having total length 0.5mtr , cf35_kf25 ss304 straight adapter having total length 50mm , kf16 ss304 flange having 1 by 4 inch od tube welded having total length 100mm , kf25 ss304 flange having 1 by 4 inch od tube welded having total length 100mm
Tender For bid to ras bid to ras corrigendum : supply of form fill seal ffs machine , cold press juice extraction machine , automatic 100 lph shell and tube type juice pasteurizer , industrial vacuum dryer , shrink wrapping machine table top , semi automatic lug capping machine , jam filling machine , vegetable and fruit slicer , continuous induction sealer , handheld smart date coder thermal inkjet printer , band sealer
Tender For 9060c26a70 rprc265074 annual rate contract for deputation of field service expert for inspection health assessment trouble shooting maintenance and overhauling of mkk make rotary vacuum filter and tsk make cta pta steam tube dryers of pta unit at panipat refinery - rprc265074 rate contract for deputation of field service expert for inspection, health assessment, trouble shooting, maintenance and overhauling of mkk make rotary vacuum filter and tsk make cta/pta steam tube dryers of pta unit at panipat refinery & petrochemical complex.
Tender For supply of disposable laboratory items - container for urine, sputum, stool sample collection, leak proof with wide mouth, conical wide bottom & screw cap, 50 ml capacity with label for patient name, ward/opd and registration number, pack size – 1 x 100 , esr disposable pipette with tube, tube 13 x 75 mm clean transparent with graduation at 0.4 ml and 2 ml should allow to fill by air pressure through the rubber piston blood lift up – up to zero level. pipette should be made with transparent polystyrene with graduate d scale 0 to 180-200. it should be fine finished; pack size – 1 x 100 , evacuated blood collection tube with spray dried k2edta with lavender safety closure. it should be made of clear latex free polyethylene terphthalate. size – 13 x 75 mm with 4.0 ml, volume capacity. batch wise gamma sterilized /pyrrogenicity/toxicity certificate should be given. it should be iso and us-fda/ce certified. firm should provide training to technicians/nurses regularly for blood collection. clinical services should be documented by company. pack size – 1 x 100 , sodium citrate evacuated tubes for coagulation test with vacuum (with na. citrate – 0.109 m/3.2% plastic tube made of clear latex free polyethylene terphthalaste with light blue safety closure, 13 mm x 75mm vol. 2.7 ml. batch wise gamma sterilized /pyrogenicity/toxicity certificate should be given. it should be iso and us-fda/ce certified, firm should provide training to technicians/nurses regularly. clinical services should be documented by the company; pack size – 1 x 100 ,, evacuated tubes for silica-clot activator/silicon coated made of clear latex polyethylene terphthalate with safety closure 13 x 75 mm vol. 4.0 ml. it should be iso and us-fda/ce certified. batch wise gamma sterilized /pyrrogenicity/toxicity certificate should be given. firm should provide training to technicians/nurses regularly. clinical services should be documented by the company; pack size – 1 x 100 , blood collection needle 21 or 22 gauge with cap for evacuated tube. it should be iso and us-fda/ce certified and gamma sterilized certificate. firm should provide training to technicians/nurses regularly. clinical services should be documented by the company; pack size 1 x 100 , evacuated tube needle holder; pack size – 1 x 5 , "clot activator for serum with gel 3.5 to 4 ml, 13 x 75 mm 1. vacuumized blood collection tube should be suitable for venous blood collection from adults and children2. should be sterile, evacuated and pet and with safety closure and single hand operation for capping and decapping 3. should provide standardized filling of blood and fit snugly on holder. should have fill mark to indicate the draw volume4. shelf life should be minimum 12 months or more from the date of manufacturing 5. the quantity of additives in the respective tube should be as per nccls/clsi guidelines. 6. should provide different color coding cap for different additives.7. the tube should contain a label for noting the patient’s details8. manufacture should provide iso and us-fda/ce certification 9. expiry dates should be printed on blood collection tubes. blood collection should be gamma sterilized. paramedical to be trained10. batch wise sterilized /pyrrogenicity/toxicity certificate should be given. firm should provide training to the technician/nurses regularly, clinical services should be documented by the company (1 x 100)11. adequate/combustion data to prove that it is safe for the environment incineration pack size (1x100)" , "clot activator for serum with gel 5-6 ml, 13 x 100 mm1. vacuumized blood collection tube should be suitable for venous blood collection from adults and children2. should be sterile, evacuated and pet and with safety closure and single hand operation for capping and decapping 3. should provide standardized filling of blood and fit snugly on holder. should have fill mark to indicate the draw volume4. shelf life should be minimum 12 months or more from the date of manufacturing 5
Tender For supply of kit of vacuum switch tube for single bottle vcb type bvac suitable for m/s btipl make or m/s aal make only as per annexure attached. btipl pt. no.- hsba331624-r1 with latest alt, aal pt.no.- sg300142r0001 with latest alt. [ warranty period: 30 months after the date of delivery ]
Tender For supply of vacuum sealed glass tube of dimension 4 mm id +/- 0.3 mm x 6 mm od x 6 inch long for hydrogen sampling [ warranty period: 12 months after the date of delivery ]