Get complete information related to latest Copper Bus Bar Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Copper Bus Bar Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Copper Bus Bar Scrap Tenders.
Tender For e.i for setting up of work station system in the audit branch of administrative office in p.u campus, sector-14, chandigarh - wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls/hffr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. frls/hffr pvc insulated copper conductor single core cable etc. as required (dsr 1.8), group c (dsr 1.8.3), rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls/hffr pvc insulated copper conductor single core cable and 1.5 sq.mm frls/hffr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required (dsr 1.15), group c (dsr 1.15.3), supplying and drawing following sizes of frls/hffr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required (dsr 1.17), 3 x 2.5 sq. mm (dsr 1.17.12), 3 x 4 sq. mm (dsr 1.17.21), supplying and drawing following sizes of frls/hffr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required (dsr 1.21), 25mm (dsr 1.21.2), supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required (dsr 1.22), 75 mm x 75 mm x 60 mm deep (dsr 1.22.1), supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required (dsr 1.24), 5/6 a switch (dsr 1.24.1), 3 pin 5/6 a socket outlet (dsr 1.24.4), supplying and fixing following modular base & cover plate on existing modular metal boxes etc. as required. (dsr 1.28), 3 module (dsr 1.28.2), 6 module (dsr 1.28.4), 8 module (dsr 1.28.5), supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 a modular socket outlet and 5/6 a modular switch, connections etc. as required (dsr 1.31), supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 a modular socket outlet and 15/16 a modular switch, connections etc. as required (dsr 1.32), supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface/ recess, complete with tinned copperbusbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (dsr 2.4), 4 way (4 + 12), double door (dsr 2.4.1), supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.(dsr 2.10), single pole (dsr 2.10.1), supplying and fixing dp sheet steel enclosure on surface/ recess along with 25/32 a 240 v "c" curve dp mcb complete with connections, testing and commissioning etc. as required. (dsr 2.16, providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. (dsr 5.18), supplying, drawing, installation, testing and commissioning of cat6a utp 4 pair, 23 awg solid copper cable in existing conduit/ on surface, u/ftp, lszh, non-plenum, horizontal (solid) cable suitable for high speed data networking application supporting upto 10gbps over a 100 meter channel. the 4 unshielded twisted pairs (utp) cable with color coded insulation for easy indentification should have flame properties i.e. flammability test - iec 60332-1, smoke density - iec 61034, lszh standards compliance: ansi/tia- 568 c.2, iso/iec 11801
Tender For maintenance of e.i in rb at chandigarh. (addition/ alteration of e.i in house no. 83, sector-23, house no. 320 and 3947, sector-22, chandigarh). - dsr item no. 1.15rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm. frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /pvc conduit including dismantling as required., group a., group b., dsr item no. 2.18 supplying and fixing 20amps, 240 volts, spn industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 amps c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required., dsr item no. 1.16rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm. frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required., dsr item no. 1.17supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required., 3 x 1.5 sq. mm, 3 x 2.5 sq. mm, 3 x 4 sq. mm, dsr item no.1.21supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required., 25mm, dsr item no.1.23supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required., 5/6 amps switch, 2 way 5/6 a switch, 3 pin 5/6 a. socket outlet, dsr item no. 1.29 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required., dsr item no. 1.30 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required., dsr item no. 1.33supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required., dsr item no.1.38 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required., dsr item no.2.3 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess, complete with tinned copperbusbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/ isolator), 12 way, double door, dsr item no. 2.4 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copperbusbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (but without mcb/ rccb/ isolator)., 4 way (4 + 12) double door, dsr item no. 2.10 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, "c" curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required., single pole, double pole, triple pole and neutral, supply and erection of electronic step type socket type fan regulator in existing b.l. sheet including making connection and petty material reqd. to complete the job. the fan regulator should be of anchor panta / havells reo/ gold medal essenza make only., supply and erection of b.l. holde
Tender For augmentation of existing 105 sq. mm. g-jumper by 160 sq. mm. g-jumper of 1st sub-sector along with replacement of 105 sq. mm. isolator jumper with 160 sq. mm isolator jumper and replacement of aluminium busbar with copperbusbar & allied works over delhi division.
Tender For corrigendum : manufacture, fabrication, supply,erection, testing and commissioning with 1x8 mva pr.tr,stn transformer, associated equipments, accessories, control panels, control room and electrical works at o.krishnapuram in trichy metro under tkc thro e tener - electrical material supply, power transformer 33/11kv, 8mva power transformer with oltc, breaker along with ct for outdoor ss 33 kv (gc) vcb (out door) 1250a, 26.3ka per 3 sec., 3 pole gang operated soild dielectric insulated with permanent magnetic actuator operating mechanism with inbuilt vcb bushing embedded dry type epoxy resin cast ct (600-300/1-1a) with structure and complete accessories with breaker platform., 11kv (lv) vcb (out door) 12 kv, 1250a, 26.3ka per 3 sec., 3 pole gang operated soild dielectric insulatedwith permanent magnetic actuator operating mechanism with inbuilt vcb bushing embedded dry type epoxy resin cast ct (1200-600/1-1a) with structure and complete accessories with breaker platform., 11kv (feeder) vcb (out door) 12 kv, 1250a, 26.3ka per 3 sec., 3 pole gang operated soild dielectric insulated with permanent magnetic actuator operating mechanism with inbuilt vcb bushing embedded dry type epoxy resin cast ct (400-200/1-1a) with structure and complete accessories with breaker platform., potential transformer 33kv potential transformer with tc (single phase unit), 11kv potential transformer with tc (three phase unit), panels ac panel for 33kv ss, 110 v dc annunciation panel type b, 110v dc indoor c&r panel for gc breaker, 110v dc indoor c&r panel for lv breaker, 110 v dc indoor c&r panel for twin feeder, control cables, junction box and accessories 14c x 2.5 sq.mm copper cable armoured, 8c x 4 sq.mm copper cable armoured, 4c x 4 sq.mm copper cable armoured, 4c x 2.5 sq.mm copper cable armoured, 2c x 2.5 sq.mm copper cable armoured, isi mark 19 / 22 mm cable gland as directed by the field engineer., isi mark 25 mm cable gland as directed by the field engineer., isi mark cable 28 mm gland as directed by the field engineer., lugs, ferrules, sleeves, cable tie, insulation tape and other accessories for providing cable core end termination, supply of gi chequerred plate 6mm thickness, junction box supply of ct/pt junction box made out of 14swg (2mm) m.s.sheet wherever required as directed by the field engineer. the box shall be vermin proof shall have sturdy hinges, provision for mounting terminal blocks and locking arrangements including cost of all materials. 400w x 300h x 150d, supply of ac junction box of size 535x310x127mm of 18swg ms sheet including hrc fuse unit-18 nos. should be fitted with base, consumables etc. (the box shall be vermin proof, shall have sturdy hinges and locking arrangements), supply of mounting channel suitable for cbtm 5 terminal block in panel /box as required and as directed by the field engineer., supply of disconnected type terminal block suitable for ct circuits in panels/ box as required & as directed by the field engineer, supply of isi mark bakelite hrc fuse holder with fuse of 2/5/10/16 amps reputed make in panels/ boxes for ac/dc/pt circuits wherever required as directed by the field engineer. 16 amps - fuse holder with hrc fuse, 63amps - fuse holder with hrc fuse, bus & bus materials zebra acsr conductor, 2.0" / 50 mm aluminium busbar (thickness:5 mm), 22/33 kv pt insulators, 11kv pt insulator, 11kv, 120kn disc insulators (antifog), strung bus eye bolt of 18 - 20 mm dia gi rod of required length suitable for 33kv, 22kv and 11kv strung bus including cost of gi rod and 2nos gi nuts & washer as directed by the field engineer., clamps and connectors tension fitting clamp 4 bolted for zebra, t clamp for 2" bus to single zebra, t clamp for zebra to zebra, switchend clamp for single zebra, switchend clamp for 2" busbar, reducer clamp for 2" bus to zebra, pg clamp for zebra, free end clamp for 2"busbar, corana bell for 50mm busbar, switch end clamp for mink, seating block for 2" busbar(for g
Tender For - arc of electrical material. - electrical work :, providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket/pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc (uv stablization report submitted for uv cover ) /toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm/ wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% ,thd(i) 10% humidity 10% to 90% rh working temp -5c to 45c . driver current 750ma. the luminaire shall be bis certified and trade mark certified. life expectancy equal or more than 50000 burning hrs with minimum 70% lumen maintened , cri >70 and cct 5700k +355k. surge protection shall be min 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. fixture shall be as per is 10322 complianced.oem must have its own in house nabl lab setup for all testing facilities for led fixtures. (lm79/lm80) certificate/ report with liable warranty of product/accessories from oem shall be submitted. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr . led street light fixture with minimum lumen output 5600 lm, supplying and drawing of xlpe insulated lt aerial bunched aluminium conductor cable confirming to is 14255/1995 and is 398 (pt-4)/ 1994 and as per discom specs. on existing cross arms through i hook with all necessary t&p required including binding and twisting etc. complete in all respect as required. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr . 1 x 25 sq. mm. + 1x25 sq. mm. (insulated), supply and fixing of 11 kv pin insulator confirming to is:731:1971 with latest ammendment on existing bracket including all accessories like ms forged hot dipped gi pin confirming to is 2486(part-i)/1993 & is:2486 (part-ii)/1989 with latest amendment, and as per latest discom specs. etc. as required. all as per pre approved by engineer in-charge.for additional technical parameters of product / work refer annexure a attached with this bsr, sitc of ip-42 and general construction confirming to is:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam/ neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) interconnection between busbar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid busbar (>63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copperbusbar shall be dully tinned . c
Tender For supply of copper plate of purity not less than 90 percentage , copper strip of purity not less than 90 percentage , copper solid rod lightning arrestor of purity not less than 90 percentage , pvc insulated multi strand copper cable of purity not less than 90 percentage , pvc pipe for earth pits , gi pipe with base plate , common salt granular , charcoal granular , brazing of interconnection , construction of inspection chamber , soil treatment , copper cable lugs ring type lugs , brass nut bolt with washer , copper equipotential earth busbar of purity not less than 90 percentage , gi cable tray with cover 300 mm width , cat6e utp cable , high-quality metallic rj45 connector with boot for cat6e cable , layer-2 manageable 16-port rackmountable network switch , adhesive anti static esd floor mat , 42 u rack , 32 amp double pole dc mcb , dc copper cable , hard excavation work , soft excavation work , sitc charges for complete earthing system and lightning arrestor