Get complete information related to latest Copper Busbar Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Copper Busbar Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Copper Busbar Tenders.
Tender For supply, installation, testing, commissioning of 400 sq.mm. single core xlpe armoured frls cu cable including lt panel box consist of 400 amps 4pole mccb, 400amps 4pole ats, suitable copperbusbar suitable flexible cable and suitable earthing etc. to supply power for em ups at phoolbagan station of east west metro corridor with 2 (two) years of dlp support
Tender For repair/replacement to bus-trunking system connected with transformer to lt panel and connected items at cariappa vihar sub- stn under age (u) e/s no ii under ge (u) electric supply delhi cantt
Tender For repairs to power transformer, bus trunking systerm sf6 circuit breaker current transformers voltage stabilizers battery banks and certain control cables and switch gears at rci hyderabad
Tender For corrigendum : providing and installation of electro-mechanical accessories at cwr site and allieds works at ekpara pwss, block-rampurhat-i under bolpur mechanical division - supply and delivery of openwell submersible pumping machinery set suitable for wet pit installation complete with stainer along with all accessories with following specification: pump : discharge (q) : (1800-1280) m3/hr. & head (h) : (19-38) mtrs.method of starting : sd, shaft-stainless steel-ss-304, impeller- crome steel/ci/s.s / bronze, suc & del size- 90/80 mm dia, type of position-horizontal. mechanical sealmotor : 12.5hp (suitable for open well)operating voltage : 415 ( 10 %), phase : 3ph, 50 hz 6%speed : 2800 rpm, method of starting : s/dmake : ksb / grundfos / texmo / cri / kbl / mbh / or any approved vendor. ( n.b : manufacturers test certificate along with charecteristics curve, moc and gurantee certyificate have to be submitted at the time of delivery.), supply & delivery at site of 35 mm x 3.5 core size aluminum armored, xlpe insulated 1.1 k.v. grade cable, conforming to is 7098(i) as per direction of eic.(make:- gloster / polycab / mescab / or any approved vendor list of phed.) ( n.b : manufacturers test certificate have to be submitted at the time of delivery.), supply & delivery of 100a kit-kat rewireable (porcelain fuse carrier & base) (make:- havells / l&t / or any approved vendor list of phed.), supply & delivery of 100 amps re-wireable porcelain fuse unit type tpn main switch with steel sheet enclosure (conforms: is/iec600947-1&3). (make: havells /approved vendor list of phed.), supply & delivery of re-wireable type tpn changeover switch 100 amps 415v, 50hz, 4 pole offload with steel sheet enclosure (conforms: is/iec60947-1&3). (make: havells /approved vendor list of phed.), 100 amps, 4way, wall mounted copperbusbar chamber with steel sheet enclosure (conforms:is/iec:60947-3). (make: havells /approved vendor list of phed.), supply and delivery of the following pipes, valves, pipes and gauges etc at site-- (make: approved vendor list of phed.), 100mm dia m.s. black pipe p/e conforming to is:1239 part-1 (2004), heavy (c class)., 150mm dia m.s. black pipe p/e conforming to is:1239 part-1 (2004), heavy (c class)., 100mm dia m.s. blank flange 15mm thick perforated as per is1538., heavy type suitable dia. ms suspension clamp along with nuts bolts and washers., 100mm dia. cast iron double flanged manually operated rising spindle type sluice valve generally conforming to is: 14846, having body, door, dome / bonnet, gland in graded cast iron to is 210 gr. fg 260, four faces of ss aisi 304 and spindle nut of gunmetal to is 318 gr. ltb 2, outside screw rising stainless steel aisi 304 spindle, valves suitable for a maximum working pressure of 10 kg/cm (seat test) & body tested to 15 kg/cm . flanges faced and drilled to is:1538 table 4 & 6. valves tested by closed end method only. (moc & tc needed for valve)., 100mm dia. cast iron double flanged single door swing non-return valve generally conforming to is:5312 part i, having body, door, cover in graded cast iron to is 210 gr. fg 260; body & door rings of stainless steel to ss aisi 304 , hinge pin of ss aisi 304, valves suitable for a maximum working pressure of 10 kg/cm (seat test) & body tested to 15 kg/cm . flanges drilled to is 1538 table 4 & 6.(moc & tc needed for valve)., 100 mm dia dismantling joint pn-1.0 ci dismantling joint complete galvanised , stud, nut and washer and follower flanges, drilled to is:1538 table 4 & 6. ( at delivery side of pump ), supply & fixing of perforated gi cable tray tee with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. s&f gi connector, 6mm dia ms suspender, bolts & nuts, steel fastener etc. as required of the following size. incl. al painting of ms support. [200x50x1.25mm x 3mtr long
Tender For supply of lt distribution panel with 04 nos suitable capacity and size copperbusbar arrange ment consisting of 02 nos .4 pole 400 amps mccb for incoming and 01 no. 4 pole 250 amps mccb , 01 no. 4 pole 160 amps mccb , 01 no. 4 pole 125 amps mccb and 02 no. 4 pole 63 amps mcb for out going along with complete wiring , indication lamp , metering arrangement and all accessories as per pcee/cege/ser s pecification no. ser/elec/gs/description /lt panel/1/rev-0/mar 2024, dimension - h x w x d - 1500mm x 1 800mm x 700mm. [ warranty period: 30 months after the date of delivery ]
Tender For supply of split air conditioner including green ac, wall mount type (v2) (q2) , supply of 11 kv, 800 amps ht vacuum circuit breaker bus coupler, indoor panel conforming to iec 62271, 200, 25 ka for 3 sec, all as mentioned in specification and as directed , installation, testing and commissioning of 11 kv, 800 amps, ht vacuum circuit breaker, bus coupler indoor panel , supply of ht bus trunking chamber adopter panel of capacity 12 kv 800 amp or nearest higher rating bus bar totally sheet metal enclosed matching with ht panel including busbar , installation, testing and commissioning of ht bus trunking chamber adopter panel of capacity 12 kv 800 amp , shifting of existing 8 nos vcb for installing of bus coupler between existing vcb and connect the bus coupler complete
Tender For supply of xlpe cable for working voltages up to and including 1.1 kv as per is 7098 (part 1) (q2) , mcb - miniature circuit - breakers for a.c. operation as per is / iec 60898 (part 1) (q2) , supply install testing commissioning of step down transformer indoor type voltage rating ht11 bye zero point 433 kv out door type of capacity 200 kva level 2 3 phase 4 wire 50 hz , supply laying and testing 11 kv earthed grades cable xlpe 120 sqmm 3 core , s and f cable end jointing kit for 11 kv grade cable for outdoor termination heat shrink type cable end complete with jointing material and accessories , s and f cable end jointing kit for 11 kv grade cable for outdoor termination heat shrink type cable end , material and labour for pcc 1 ratio 4 ratio 8 type d2 using 40 mm graded stone aggregate for making good cutting portion mass concrete , m and l for pcc 1 ratio 3 ratio 6 type c2 using 40 mm graded stone aggregate for making good cutting portion mass concrete filling of foundations etc including necessary use and waste of form work , supply and fix tpn distribution board 4 way acrylic door 415 volts ac tpn for flush mounting with 100 amps double door copperbusbar neutral bar earth bar and mcb incomer of rating upto 100amps , material and labour for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directely in ground vertically , supply install testing and commissioning of lt feeder panel of size 1500 x 1500 x 600 mm 3 phase 4 wire 415 v 50 hz ac outdoor type , m and l for brick sub class b 250x115x75 mm and laid in trenches as in protection of ug cable , supply and filling in and spreading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover , returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed , removing excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1 point 5 mtr above the starting point all as specified and directed , m and l for gl pipe 100 mm light grade laid in trenches floors bye on pole bye road for cable protection with all fittings complete all as specified and directed , boaring holes horizontally under road without damaging the surface of road minimum1pointzero mtr bellow the road surface with the help of gl tubing of any dia not exc 80mm dia for passing of ug cable , supplying and laying reinforce precast concrete cable cover class ht type 1 flat size 300 x180x40 mm for protection under ground ht cable complete all as specified and directed