Tender For work of enhancement of current carrying capacity of 132kv hatia ii ckt i and ii double circuit transmission line by replacing acsr panther conductor to acsr moose conductor of 132 33kv grid sub station hatia i.
Tender For supply of single core thin walled electron beam irradiated copperconductorcable, si ze 16 sq mm, with copperconductor, working voltage above 750v & up to 1.8/3.0 kv, suitabl e for use in rolling stock application, as per rdso specification no elrs/spec/elc/0019 (rev- 4) of feb- 2018. [ warranty period: 30 months after the date of delivery ]
Tender For repairing of damaged y ph.(top conductor-twin-moose) conductor by dismantling/stringing with repair sleeve/joint sleeve on 400 kv charal-kosamba line between 146(s) to 147(s) under 220 kv limbdi jurisdiction of am div. limbdi of tr circle surendranagar.
Tender For survey for conversion of 400kv rtps-btps s/c line twin moose line by dc line with quad moose conductor in 400kv tlm toranagallu division for a distance of 152kms.
Tender For procurement of tools and plants for stringing in live hot line - 18mm plateena rope with break indicator -500 mtrs , 18mm plateena rope with break indicator -1000 mtrs , hanging rollers - double sheave- for conductor , leight weight single sheave aerial rollers for conductor -acsr moose or zebra or bersimis , two sheeve pulley block 2 nos per set suitable for 20 mm dia poly propylene rope having 5 t capacity , single sheeve pulley -open type- suitable for poly propylene rope-5 tcapacity for 24 mm dia rope , single sheeve pulley -close type- suitable for poly propylene rope5 t capacity for 24 mm dia rope , d-shackles-6.5t capacity , bolted type flat -patta- clamp for 7 by 3.66mm earth wire , 4 sheeve pulley block 5 ton capacity -2 nos- 1set , 12 mm dia steel 300 meter wire rope , articulated swivel joint , equalizer pulley-10 t capacity , light weight automatic type come along clamps for acsr moose conductor , light weight automatic type come along clamps for acsr zebra conductor , light weight automatic type come along clamps for acsr bersimis for 765kv , steel wire rope sling for 12 mm x 1 meter both end spliced , steel wire rope sling for 18 mm x 1 meter both end spliced , steel wire rope sling for 18 mm x 2 meter both end spliced , steel wire rope sling for 18 mm x 2.5 meter both end spliced , steel wire rope sling for 18 mm x 5 meter both end spliced , 12 mm dia-poly propylene rope bundle of 220 meters each , 18 mm dia-poly propylene rope bundle of 220 meters each , 20 mm dia-poly propylene rope bundle of 220 meters each
Tender For conducting detailed survey for strengthening of existing 400kv nelamanagala-devanahalli & nelamangala-signayakanahalli (yelahanka)-devanahalli dc lines from twin moose acsr to hpc twin conductor running on 400kv dc towers passing in nelamangala, doddaballapura, yelahanaka & devanahalli taluk, bengaluru urban & rural district, based on modern survey techniques
Tender For corrigendum : rate contract for supply of electrical spares n minor store/hardware items, as given in the detailed boq, from govt approved reputed experienced competent n financially sound electrical contractors/firms/suppliers/joint ventures/executors/oems - part: (a) 132kv transmission lines (material ), al. alloy as per is: 617 of 1975 pg clamps 3 bolt type conforming to is: 5561-1970 (amended upto date) for acsr zebra conductor (make: rul, zi, honeywell, burma, pee, equivalent etc/ as per departmental sample provided)., p g clamp for acsr panther conductor as per relevant is/iec amended upto date and of reputed/standard make, p g clamp for acsr moose conductor as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic ct clamp (universal take off) for panther conductor with ct terminals suitable for 132kv/33kv cts as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic isolator pad clamp (universal take off) of panther conductor with pad terminals suitable for 132kv /33kv isolators as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic isolator pad clamp (universal take off) of zebra conductor with pad terminals suitable for 132kv /33kv isolators as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic breaker pad clamp (universal take off) of zebra conductor with pad terminals suitable for 132kv /33kv breakers of sf 6 type-abb,cgl, siemens, bhel/vcb type- s&s, gec alsthom, bhel, abb, siemens, megawin etc as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic ct pad clamp (universal take off) for twin acsr zebra conductor with conductor spacing 300mm and ct terminal spacing of 140mm having bolts hot dip galvanized nuts and washers electro galvanized and current carrying capacity equivalent to ampacity of twin zebra conductor with pad terminals suitable for 132kv /33kv ct as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic twin isolator pad clamp (universal take off) conforming to is: 5561-1970 (ammended upto date) for twin acsr zebra conductor with conductor spacing 300mm and isolator pad clamp terminal spacing of 140mm having bolts hot dip galvanized nuts and washers electro galvanized and current carrying capacity equivalent to ampacity of twin zebra conductor with pad terminals suitable for 132kv /33kv isolator as per relevant is/iec amended upto date and of reputed/standard make, bimetallic ct pad clamp (universal take off) conforming to is: 5561-1970 (ammended upto date) for twin panther conductor with conductor spacing 300mm and ct terminal spacing of 140mm having bolts hot dip galvanized nuts and washers electro galvanized and current carrying capacity equivalent to ampacity of twin panther conductor as per relevant is/iec amended upto date and of reputed/standard make, bimetallic breaker pad clamp (universal take off) conforming to is: 5561-1970 (ammended upto date) for twin panther conductor with conductor spacing 300mm and terminal spacing of 140mm having bolts hot dip galvanized nuts and washers electro galvanized and current carrying capacity equivalent to ampacity of twin panther conductor as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic isolator pad clamp (univercial take off) conforming to is: 5561-1970 (ammended upto date) for twin panther conductor with conductor spacing 300mm and isolator terminal spacing of 140mm having bolts hot dip galvanized nuts and washers electro galvanized and current carrying capacity equivalent to ampacity of twin panther conductor with pad terminals suitable for 132kv /33kv isolator of reputed/standard make, bi-mettalic isolator pad clamp (univercial take off) conforming to is: 5561-1970 (ammended upto date) for single panther conductor of reputed/standard make, t-clamps 3 bolt type conforming to is: 5561-1970 (amended upto date) for acsr -panther-acsr panther conductor of repute
Tender For providing and fixing electrical equipments accessories mechanical spare parts and electrical installation to pump house at paddal and tarna - providing and fixing new ball bearing 7312 skf make (begap) complete in all respect as per the direction and to the entire satisfaction of the engineer-in-charge in all leads and lifts., providing and fixing new ball bearing nu 412 skf make complete in all respect as per the direction and to the entire satisfaction of the engineer-in-charge in all leads and lifts., providing and fixing new ball bearing 6314 skf make complete in all respect as per the direction and to the entire satisfaction of the engineer-in-charge in all leads and lifts., providing and supplying gland dori 16 mm in all leads and lifts., providing and supplying gland dori 14 mm in all leads and lifts., providing and supplying gland dori 10 mm in all leads and lifts., repair / overhauling of 5.00 hp monoblock pump set including cost of change of ball bearing no. 6307 & 6308 in 2 nos. pump sets and dismentling, assembling, testing and carriage of pump at site of work including labour charges complete in all respect as per the satisfaction of engineer-in-charge in all leads and lifts., repair / overhauling of 200.00 hp centrifugal pump set including cost of change of sleeves, cleaning and regreasing of all bearing and dismentling, assembling, testing and carriage of pump at site of work including labour charges complete in all respect as per the satisfaction of engineer-in-charge in all leads and lifts., providing and supplying rechargeable led torch 3 watt (wipro) make complete in all respects and to the entire satisfaction of the engineer-in-charge., providing and fixing three core submersible flat cable 10.00 sq. mm for submersible pump set of plaza / finolec make in all leads and lifts., wiring for light point/ fan point / exhaust fan /call bell point with 1.5 sq. mm. pvc insulated heat resistant flame retardant (hrfr) and low smoke single core (flexible) copperconductorcable in surface/recessed pvc conduit and earthing the light point with 1.5 sq.mm. hrfrls/pvc insulated single core copperconductorcable as required., supplying and fixing metal box of 180mmx100mmx60mm deep (nominal size) on surface/recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 5 pin 5/6 amps socket outlet and 5/6 amps, piano type switch, connections, painting etc. as required., supplying and fixing metal box of 180mmx100mmx60mm deep (nominal size) on surface/recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 6 pin 15/16 amps socket outlet and 15/16 amps, piano type switch, connections, painting etc. as required., wiring for circuit/sub-main with following size pvc insulated heat resistant flame retardant (hrfr) and low smoke single core (flexible) copperconductorcable in surface/recessed pvc conduit along with 1 no. hrfrls/pvc insulated single core copperconductorcable of same size for earthing as required.2x1.5 sq. mm., 2x10.0 sq. mm., supplying and erection of 6 amps. to 32 amps. rating, 10 ka breaking capacity, 240 volts, c curves, miniature circuit breaker of following poles in the existing mcb db complete with connections etc. as required:- single pole. cat-a., supplying and erection of 40/50/63 amps rating. 10 ka breaking capacity, 240 volts, c curves, miniature circuit breaker of following poles in the existing mcb db complete with connections etc. as required:- double pole. cat-a., supplying and fixing of following way, single pole and neutral sheet steel mcb distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-single door-6 way, supplying and fixing bakelite batten/angle holder including connect