Get complete information related to latest Cortical Screw Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cortical Screw Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cortical Screw Tenders.
Tender For e- tender for supply of orthopaedic trauma and arthroplasty implants high end - hemihydrate calcium sulphate kit 10- cc, hemihydrate calcium sulphate kit -5 cc, distal femur nails for standard and periprosthetic fractures with larger distal bends and with locking attachment washer or condular nuts and washers, us fda approved, reamer bone harvesting kit with reamer head and reaming rod , us fda approved , variable angle locking calcaneal plate 2.7mm with/without tab small/medium/large -, 2.7mm va locking screw -, 2.7 mm metaphyseal screw 2.7mm cortex screw variable angle locking screw should have option to lock at plus -15 degree off axis in any direction compele range of size shape and side specific implant with instumentation at the time of surgery.implant should be us fda/eu-ce/bis standard compliant., low profile distal tibial medial plate 3.5mm,6-14 holes,titanium, locking head screw 3.5 mm, l 10-60 mm, titanium, corticalscrew 3.5 mm self tapping, l 10-60 mm, titanium, cancellous screws 4mm full/half threaded, l-20-80mm,titanium variable angle locking screw should have option to lock at plus -15 degree off axis in any direction compele range of size shape and side specific implant with instumentation at the time of surgery.implant should be us fda/eu-ce/bis standard compliant., lcp anterolateral distal tibia plate 3.5mm, right or left,(5-21)holes, titanium, locking head screw 3.5 mm, l 10-60 mm, titanium, corticalscrew 3.5 mm self tapping, l 10-60 mm, titanium, cancellous screws 4mm full/half threaded, l-20-80mm,titanium, radial head replacement system is a solution for replacing the radial head for radial head fractures to restore elbow stability and forearm rotation to maintain the legth of radius. implants should be available in 19 mm,22 mm,25 mm variant and available in stem varing 5.5 mm to 8.5 mm and stem length 21 mm to 24. the implants should be uncemented with all instruments in sterile form for one time use., polymethylmethacrylate (pmma) injectable bone cement system for augmentation of proximal femoral nailing system (tfna) through cannulated implants and instruments for patients with poor bone quality (such as osteoporosis). its applicator allows surgeons to inject cement into the femoral head through cannulated implants, reducing the risk of cut-out, locking attachment plate 3.5 mm is a fixed-angle construct in periprosthetic fractures and fractures in the presence of intramedullary implants, particularly in osteopenic bone where screw purchase is compromised the plate is attached to existing locking compression plates (lcp using a connecting screw, to augment stabilization of fractures.the arms on each side of the plate offer the possibility of bypassing the prosthesis stem with 3.5 mm locking screws (or 3.5 mm cortex screws)., locking anterior patella variable angle plate for simple and complex patella fractures should have range of plates - core, to address different fracture pattern with 2.7 mm va locking screws and 2.7 cortex screws. variable angle locking screw should have option to lock at 15 degree off axis in any direction compele range of size shape and side specific implant with instumentation at the time of surgery.implant should be us fda/eu-ce/bis standard compliant., variable angle locking hand system consists of plates that are anatomic, procedure-specific for the fracture fixation of metacarples and phalanges, 1.3 mm profile plate configuration includes either straight plate/ t-plate/phalangeal base plate/y- plate/strut plate/web plate/phalangeal head plate, the construct consists of plate 1.3 mm, va locking head screw 1.3mm, corticalscrews 1.3 mm., variable angle lcp clavicle plate which can be used for lateral extension, medial, shaft, anterior and for ac joint fracture. the construct consist of plate, locking head screw 2.7 mm and corticalscrews 2.7 mm, (compele range of size shape and side specific implant with instumentation at the time of surgery.implant should be us fda/eu-ce stan
Tender For supply of kirschner wire 250 mm long x 20 mm dia both ends trocar point , kirschner wire 250 mm long x 10 mm dia both ends trocar point , threaded guide wire 25 mm dia x 22 cm , postoperative presterile silver hydrofibre waterproof orthopaedic flexible dressing 9 x 35 cm , injectable fast setting synthetic bone void filler , titanium elastic nail with end cap , distal radius volar locking plate complete construct with 6 locking and 3 corticalscrews , threaded guide wire 32mm diameter with stop length 25 cm approx , titanium endobutton with adjustible length suspensory loop made of suture made of uhwpe core with braided polyester jacket for femoral fixation of tendon graft for acl reconstruction , porous hydroxyapatite with tricalcium phosphate granules 30 ml , porous hydroxyapatite with tricalcium phosphate cylinder 10 mm long 5 mm dia , cling drape film roll sterile transparent , joint irrigation fluid 3 ltr collapsible pack normal saline , high performance orthopaedic operating gown sterile waterproof wrap around type sealed at seams and not stitched low lint fabric gsm 43 or higher pe reinforced , orthopedic sterile latex powder free gloves with lead lining for radiation protection different sizes size 7 or 75 or 8 , clavical hook plate with screw- titatnium bid number/ & ( * ) : gem/2025/b/6197596 dated/ + : 26-05-2025 bid document/ 2 2 1 / 18