Get complete information related to latest Coupler Head Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Coupler Head Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Coupler Head Tenders.
Tender For supply of set of couplers for vande bharat rake (crashworthy design) note:-firm shall collect all latest/final specification/drawings before manufacturing. there may beminor modification in design., as per drawing: mp24vbcccb version 1, packing instruction: lhbcbcs are being used in two stages in rcf and as per shop (using ) practice , it is proposed that lhb/cbcs to be packed in two wooden boxes as per packing instruction here under :- 1.packing -i:- un-coupling device with hardwares and other related acessories. all related hardwares to be packed separately in jute packing to avoid rusting/corrosion of hardwares . pl no to be printed/marked on packing slip and 'for use of fur group' tobe marked on box . 2.packing -ii:- one couplerhead, one draft gear with hardwares and other related acessories. all related hardwares to be packed separately in jute packing to avoid rusting/corrosion of hardwares .machined surfaces must be covered with corrosion resistant paint/substance. pl no to be printed/marked on packing slip and 'foruse of underframe group' to be marked on box . note: (i) item no. i, ii should be packed in separate boxes. (ii) a list should be pasted on each box showing order no. , pl no., description of item drg. no./spec. no., qty., firm's name, address , user name as above & dateof despatch etc. [ warranty period: 30 months after the date of delivery ]
Tender For supply of improved high tensile tight lock center buffer coupler with aar-h type head and balanced draft gear for fitment on bg passenger coaches confirming to rdso specification no. specification rdso/2011/cg-03 (rev.-3) amendment slip no. 1 of july 2024 consisting of 6 items, (sl. no. 1) tight lock couplerhead aar-h type with main pin. qty. 1 no., (sl. no. 2) balance draft gear. qty. 1 no., (sl. no. 3) supporting device with fasteners. qty. 1 no., (sl. no. 4) manual uncoupling device. qty. 1 no., (sl. no. 5) front carrier plate with fasteners. qty. 1 no. as per rdso letter no. mc/blb/cbc dated: 24.04.2025 (sl. no. 6) rear carrier plate with fasteners. qty. 1 no. material & specification as per specification no. rdso/2011/cg-03 (rev.-3) with amendment slip no. 1 of july 2024. [ warranty period: 84 months after the date of delivery ]
Tender For bid to ras supply of electrical items c c - ml for flame proof point wiring with two single core frls h pvc insulated pvc unsheathed multi stranded copper conductor cable of size 1 point 5 sqmm 1100v , supply install testing of flame proof metallic body exhaust fan single phase 230v 50hz 300mm 1440 rpm with louvers and shutter including civil work , ml switch flame proof rotory type with termination box in lm 6 16 a single phase 250v complete all as specified and directed by engr in charge , supply and fixing db spn 4 way db including all fixing accessories complete all as specified and directed by engr in charge , supply and fixing mcb sp 6 to 32 amps 240v rupturing capacity 10 ka c series complete all as specified , supply and fixing mcb db 20 amps 240v breking capacity 10 ka complete all as specified , ml for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick surrounded with charcoal and salt buried directly in ground , ml for submain wiring with 2 single core pvc insulated unsheathed multi stranded copper conductor frls wire 4 sqmm 1100v grade incl one 4 sq mm pvc insulated , supply lay jointing testing xlpe insulated lt under ground cable 1100v grade heavy duty armoured with multi stranded aluminium conductor laid in trenches ducts , excavation in trenches n exc 1 point 5m wide and n exc 1 point 5m in depth for foundation etc or for shafts wells cesspits manholes pier holes laying of cables etc , ml for tibba sand cushioning to under ground cable in trenches existing cable trenches ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying , ml for 40 to 50 mm thick rough dressed jodhpur type stone slab 25 to 35 cm in width of 80 cm long laid dry abutting each other for protection to under ground cable , ml for removing excavated material to a distance n exc 50m and depositing where directed at a level n exc 1 point 5m above the ) /bid number : gem/2025/b/6562017 * /dated: 20-08-2025 & & / bid document 1 / 20 & & ' ' /item category starting point complete , ml for returning, filling in including spreading leveling watering and well ramming in layers not exc 25 cm complete all as specified and as directed , ml for gi tubes in replacement of 32mm bore size light grade galvanised including fittings with clamp of 25x3 flat iron welded to pipe fixed to wall , supply install testing or commissioning of inverter tech split wall mounted ac indoor outdoor unit with cordless remote control cap 1 point 5 tr make lg blue star hitachi voltas lyod , supply fixing heavy duty copper pipe 12mm 1 oblique 2 inch dia bore thickness 0 point 70 mm complete incl brazing welding nuts bolts and screws , supply fixing heavy duty copper pipe 6mm 1 oblique 4 inch dia bore thickness 0 point 70 mm complete inclu brazing welding nuts bolts and screws , supply and fixing new nityrile rubber insulation for copper pipes suitable for split ac of capacity from 1 point 5 to 2 tr complete all as directed by engg in charge , supply fixing in replacement wall mounted digital voltage stabilizer for automatic operation single phase naturally air cooled indoor type designed for input variation between 150 to 285v , sf sheet metal enclosure 2 pin earth plug socket complete with one single pole mcb of 20 amp capacity complete all as specified and directed by engr in charge , sf wiring from indoor to outdoor unit size 2 point 50sqmm pvc insulated multistranded frls 4 core round cable incl fixing of thimbles for split type air conditioner 1 point 5 to 2 tr , m l for surface sub main wiring with two runs of 4sqmm single core pvc insulated unsheathed multistranded with copper conductor cable 1100v frls h grade isi marked , supply fixing new pvc drain pipe 15 mm dia with coupler joint for split or window ac complete all as specified as directed , supply fixing in replacement outdoor unit odu stand for 1 point 5 or 2 tr type split ac complete all as specified as directed