Get complete information related to latest Cpu Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cpu Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cpu Tenders.
Tender For tender for supply of sitc and maintenance of addressable fire alarm and detection system at uco bank - supplying , installing , testing and commissioning approved make microprocessor based multi-loop , networkable addressable 02 loop fire alarm control panel with minimum 10 inch 1024x600 resolution lcd with touch capability , including audible and visible feedback , backlit by a long life , solid-state lcd. it shall also include a full qwerty-style keypad on the color , touchscreen display. the display shall have the ability to scroll events by type (i.e. fire alarm , supervisory alarm , trouble , etc) using the touchscreen with customizable buttons , 10000 history events & autolearn feature for programming. the system can be supported upto 2000 generation zone & 2000 logic zone & 50 releasing zone. the panels in network having true peer to peer provision. the panel shall have provision to support up to 50 releasing zones to protect against 50 independent hazards.the panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 loops. , supplying , installing , testing and commissioning approved make modbus interface gateway for communication with bms / other utilities. modbus shall support supports reads of up to 100 registers at a time. modbus gateway shall act as an independent node communicating on the peer to peer network and shall not be dependent on the fire panel cpu for operation. modbus over tcp/ip , meets ul 864 , 10th edition requirements , supports two modbus masters & monitored 10 cpu nodes . failure of fire panel cpu shall not result in failure of modbus gateway. the gateway card shall be ul listed , the mimic annunciator for the fire alarm control panels (facp). this provides the facp with remote , serially-connected display. a five inch touchscreen display provides system status , point information , and event counters. the display shows two events simultaneously , and pages through up to 50 of the highest priority events in the system. the remote display also provides system control with six programmable softtouch buttons as well as acknowledge , silence , reset and drill. , supplying , installing , testing and commissioning approved make addressable multi-criteria photo-thermal detector with sensitivity range of 0.5 to 4.0% obs/ft.the intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. it shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. the detector shall have twin bi-colour led for 360 deg viewing. addressing shall be with user friendly rotary decimal switches. detectors having base addressing must provide protective cap. detectors with soft addressing must provide programming tool. the detector sensitivity (day & night) shall be controlled from the panel to get accustomed to the local environment. the detector shall be ul listed & fm approved. , supply , installation , testing and commissioning addressable self-test multi-criteria photo-thermal detector with sensitivity range of 0.5 %/ft to 4.0 %/ft obs. intelligent multi criteria detection device shall include the ability to combine signal of the thermal sensor with photoelectric signal in an effort to react hastily in the event of a fire situation. , supplying , installing , testing and commissioning approved make addressable manual call point ( break glass type). the device shall have an led which shall blink in normal state & get steady on activation to monitor the heath status of the device. the device shall be ul listed & fm approved. , supplying , installing , testing and commi
Tender For supply of ups 1 kva , ups 2 kva , ups 3 kva , ups 5 kva , ups 10 kva , window ac 2 ton , split ac 2 ton , fcbc 48v , uhf 34 mb radio base radio , otdr , splicing machine , optimux , fxo oblique fxs , ip dslam 24 ports , 24 port layer 3 core switch , 24 port layer 2 core switch , 2 oblique 34 mb opti mux 16 into e1 plus 4 into ethernet port , pcm mux with quad e1 coma 12 fxo coma 12 fxs coma 4 into ethernet port , line extension card for 16 ports , ip gateway card for 48 channels , stabilizer 4 kva , optical card for optimux , e1 interface convertors , optical line terminal , video grid display sys , lcd display panel , digital cross connect multiplexer with single cpu 32e1 plus 8 fxo plus 8 fxs plus 4eth and dual power supply , l2 switch 24 port with two sfp 20 km , ofc cleaver diamond cutter
Tender For network video recorder (nvr) unit with accessories, suitable for three-phase memu coaches of medha propulsion rakes, similar to hikvision model no. ds-m7508hni/gw/wi (m12) or as per medha code no. sp675m801001, or equivalent. technical specifications: (i) 2 tb hdd with 2 gb cache memory, (ii) 32 gb sd card,(iii) 8-channel nvr with m12 connector only, along with necessary software and control equipment. the nvr shall conform to icf specification no. icf/md/spec-269, issue status: 02, rev. 00, and shall be compatible with the cctv system installed in memu coaches with medha propulsion. one sample shall be approved by interfacing with the existing cctv system prior to bulk supply. [ warranty period: 30 months after the date of delivery ]