Get complete information related to latest Cricket Mat Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cricket Mat Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cricket Mat Tenders.
Tender For corrigendum : supplying and fixing of adventure sports activity equipments in top sengattupatti in uppiliyapuram block in tiruchirappalli district under tanii 2023-24 package no.1
Tender For providing and fixing of sports equipments for sports courts under bairamalguda flyover at sagar road junction in ward.no. 16,hasthinapuram of l.b.nagar circle-4, ghmc.
Tender For purchase of gym for strength and conditioning equipments - endurance sectiontreadmill1. machine must be designed for running with heavy duty 4 hp motor.2. should have low start up speed: 0.5 kmph or lesser.3. should have incline increments of 1% or lesser.4. low step height: 7 or lower.5. speed range: 0-20 kmh or more.6. incline: 0-15% or more.7. max user weight: 180 kgs or more.8. belt size : 61 x 22 or more9. should have at least 10 preprogrammed protocols with option for heart rate range control10. led console with feedback for time distance, calories burnt, heartrate, incline, track and more product should have en-957 or astm certification for stationary fitness equipment, curved non- motorized treadmill (self- powered)1. curved non-motorized treadmill should be capable of training the body s all energy systems as a comprehensive system, capable of offering sprinting for aerobic power development2. curved non- motorized treadmill (self powered) should be capable of offering the sports persons to experience a full speed resistance spectrum.3. variable resistance: the curved non- motorized treadmill (self powered) system should have requisite advanced drive technology enabling users to select different levels of reactive resistance, from zero to max. by simply shifting the drive control system, rehab athletes can quickly switch from resistance-free running to an all-out sled push.4. increased metabolic rate: walking with resistance on said curved non-motorized treadmill (self powered) training system should be capable of enhancing energy expenditure significantly compared to walking at the same speed on a traditional treadmill or a non- motorized treadmill without resistance.5. maximum muscle activation: ergonomic design of the curved non-motorized treadmill (self powered) training system should lead to significantly higher activation of the posterior kinetic chain muscles, particularly the glutes and hamstrings, compared to traditional treadmills.6. curved non-motorized treadmill (self powered)- training system should be capable of being operated and controlled exclusively by the force applied / generated by rehab athletes. in order to speed up, provision should be there, where rehab athlete can move to the front of the surface and to slow down, rehab athlete can move to the back of the said treadmill. provision must be there where the training system can be accelerated quickly from a cold start and matches upto the same pace as the rehab athletes intends to attain. the said system should offer an ideal solution for an eco-sustainable facility, by reducing electricity costs and carbon footprint.7. training system should have requisite technology, ergonomic design and advanced engineering solution so that rehab athletes can work hard in a completely safe training environment.the ergonomic design combined with the high- quality components and materials should be of solid, compact product with a versatile nature that endures well to suit high intensity prolong training sessions to ensure maximum durability and reliability.8. provision for proper posture control:the ergonomic design of training system promotes the correct alignment of the ankles, knees, hips and back, so that user can maintain natural posture at all- times and avoid joint and knee stress, regardless of their height and weight. system should offer the provision of simulating the experience of walking/running uphill while preserving the correct biomechanics.9. accessory kit: the training system must be provided with accessory kit which allows for a variety of pulling and pushing exercises through handles or a waist belt.10. technical specifications:a) dimensions range (lxwxh)*:190-200cmx86- 95cmx150-160cmb) console type: a minimum of 6-7 lcd display with back lightc) power supply: lps 5v wall supplyd) power requirement: 200 - 240 v (should comply with standard indian electrical system)e) resistance control: should have magnetic resistance with a minimum of 8-10 l
Tender For purchase of sports physiotherpy lab equipments - focused shockwave therapy the device should be suitable for musculoskeletal use. should be a focused shockwave based on piezo mechanism. should have multi array type piezo electric hand piece. should have accuracy of the shock wave generation cycle(frequency)0~8 10% should have software-based operating system the unit should have large color touch screen for ease of operation. the unit should have accuracy of the operating frequency 0~7000shock 10% the unit should have maximum energy density 0.702 m j/ (when setting at 23 levels) 15% should have shock wave penetration depth 40 20%. should have maximum focus size. 78 1.78 15.81 20% should have maximum pressure 44.01 0.65 mpa the unit should be supplied with piezo hand piece and elastomer gel padas of 8 different sizes, 5mm, 10mm, 15mm, 20mm, 25mm, 30mm, 35mm, and 44mm. the life span of hand piece should be of up to 10 million shocks. should be supplied with trolley with castor wheels. dimension of the device should be approximated 500mmx700mmx 1000mm should have ce or usfda certified., high laser therapy should be class iv high level laser therapy system should have a real-time operating system technology should have maximum laser should be class iv high level laser therapy system should have a real-time operating system technology should have maximum laser power output of 15 watts should have wavelengths of 810 nm & 980 nm should have an aiming beam of 650nm, should have 2 operating modes: continuous wave or pulsed applicate and piece should have embedded finger switch and light, should have a technology to customize patient treatment based on conditions, body area, body type, skin type, chronicity and absorption characteristics applicator should have a fused silica composition massage ball at the point of contact of applicator and skin. pulse frequency: 2, 10, 20, 100, 200, 500, 1000, 2500, 5000 & 10000hz pulse duration: 50% duty cycle at any given pulse frequency setting, should have a 10 hd display touch screen with password protection to reach the home screen should be supplied with 2nos. of laser protection glasses power: 100-240v, 50-60 hz the unit should be supplied with 5 different types and sizes of treatment heads (large cone, large massage ball, flat window, small massage ball, and small cone. the unit should have inbuilt battery. electrical safety class: class i, type b weight should not exceed 4 kilograms (main unit; without applicators & accessories. must have class iii also., combination therapy machine with vaccum should have 3 independent electrotherapy channels, one ultrasound channel should provide multiple clinical waveforms including interferential (2 and 4 poles and isoplanarvector), tens (asymmetric biphasic &symmetric biphasic), han, russian, vms, surged(rectangular &triangular), hvpc, microcurrent, galvanic (continuous, interrupted and low level),rabert & dia dynamic cpid/cpiso should have independent parameter adjustments for each channel including intensity, frequency, duty cycle, vector scan, channel mode, phase duration, ramp, cycle time and treatment time based on waveform should have maximum output intensity up to 140ma should have constant current and constant voltage modes should have 2 colour coded lead wires for easy picking of selected channels should have suggested electrode placement guidelines ultrasound should offer 1 and 3 mhz frequencies should have the ultrasound bnr of 5:1 or lesser should be supplied with one 5cm applicator head should have pulsed & continuous frequency modes (10%, 20%, 50% & 100%) should have variable duty cycles of 16 hz, 48 hz &1 bb 00 hz should have facility to indicate applicator uncoupling should be able to use electrotherapy and ultrasound independently and also in synchronizedcombination of electrotherapy and ultrasound, where ultrasound head functioning as bothultrasound head and electrode should have minimum 7 high resolut
Tender For purchase of sports exercise physiology lap equipments - cardiopulmonary exercise testing system system should be compact can be used in laboratory operation and low maintenance costs and easy servicing. system should be state of the art computerized telemetry breath test analyzer for on-line breath by breath measurement of exercise test of respiratory system to measure following parameter: time, ve, bf(rr), hr, feo2, feco2, peo2, peco2, vo2, vco2, ve/vco2(eqco2), ve/vo2(eqo2), rq(rer), vd/vt, vo2/kg, vo2/kg/hr, met, watt(work), hr, ttot, ti, te, ti/te, ti/ttot, pef, pif, br, vet, sum, tv/te, o2 kinetics, oxygen deficit, oxygen debt parameters and indirect calorimetric. wireless hr recording system, indirect cardiac output by wassermann algorithm system should comply ats and ers guide line and it should be ce certified., iso certified system should have automatic ambient conditions measuring system. system should work under temperature range 0 to 50 celsius. system should have facility for automatic calibration of analyzers. volume transducer calibration with precision calibration syringe. system should meet following technical specification flow rate measurement: measuring headpiece should be either through turbine /dvt/ pneumotach and dead space less then 40 ml, it should not be affected by humidity , flow range +/- 18 l/s and accuracy 2% oxygen analyser : should be either electrochemicalcell/paramagnetic and measurement range 0- 100 %,response time t90 100 ms and accuracy +/-0,04 % and- resolution 0,02 %carbon dioxide analyser : should be ndir (infraredabsorption) and measurement range 0 - 10 %,-response time t90 90 ms , accuracy +/- 0,04 %, andresolution 0,02 % software should support latest windows or latest andin corporate customized predicted normal equations.software should be capable of changing graphics displays during real time testing. system should have facility for automatic treadmill or bicycle ergo meter control. should be supplied with software, standard accessories for operation manual carrying case for field use. system should be supplied with latest data acquisition system, deskjet printer and ups. system should comply en iso 13485:2003, en iso 9001:2000, ec certificate93/42/eec, programmable treadmill running machine with user terminal (display &keyboard) stand- alone and remote control via rs232 running surface: l:170 cm (minimum), w: 65 cm (minimum) maximum possible load: 200 kg (440 lbs) speed range: 0-40 km/h elevation: 25% (14 maximum elevation) motorized adjustment, reverse belt rotation. motor system 3.3 kw, single phase ac motor, maintenance free and brushless power transmission: frequency inverter, poly v- belt, very quiet operation safety system: emergency-off safety stop switch (safety lanyard with actuator, pull cord and clip); potential equalization bolt; transformer for potential-isolation from the mains ambient condition: temperature: +10to +40 degrees c, humidity 30 to 70% display (resolution): lcd display heartrate monitoring: wireless transmitter; the treadmill should be able to interface with well-known compatible metabolic gas analyzer as per standard and custom exercise protocols different programs safety harness-1. indispensable accessory for stress testing, accident prevention and for the general safety of athletes.2. safety arch with different heights and widths to fit all running machines.3. an emergency stop at the crossbar of the safety arch allows automatic stop of the running belt in the moment a fall occurs.4. the harness and chest belt (available in 5 sizes: xxs, s, m, l, xl) secure the subject and prevents falling over to the front.5. chest belt straps do not pinch or restrict the athlete", programmable ergometer functional design and excellent stability, load up to 160kg. easy to use saddle, handle bar and pedals speed independent and dependent power control handle bars are easy to change to suit different tests, rotatable by 360 degrees. mechanical/motor-assisted seat a
Tender For sports equipments, indoor single badminton court with installation of iron structure of standard size with proper exhaust system and court marking, , moveable badminton pole and net, , badminton rackets, , shuttle cocks, , table tennis rackets, , table tennis balls