Get complete information related to latest Ct Meter Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ct Meter Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ct Meter Repair Tenders.
Tender For corrigendum : for running contract for hon,ble sansad nidhi/vidhayak nidhi and other deposit works under edd-budaun (semi turnkey). - cartage of following material from store center nawada, budaun to je store/je store to site of work including loading & unloading at both ends maximum distance up to 30 km., a) pcc pole 8.5 mrt long/st pole 11 mtr long., b) 11 kv xlpe cable of 3x70/3x120/3x185/3x300 sq.mm., c) 250/400 kva t/f., d) 11 kv ct/pt unit of different size, e) 11 kv jointing kit of different size, f) 11 kv pilfer proof cubical of different size, g) lt abc cable of size 1x16, 3x50, 3x95, 3x120 sq.mm., cartage of line material (11 kv pin insulator, disc insulator, stay set, cross arm, gi wire, earthing rod, ms channel, ms angle, etc) from store centre to dump site & then dump site to site of work on day to day basis, including loading & unloading at both ends maximum distance up to 30 km., cartage of 10 kva & 25 kva transformer from store centre to site of work including loading & unloading at both site, the work of safe carriage 11 kv o/g vcb store center nawada budaun to work of site distance up to 0 to 30 km including safe loading & unloading., cartage of 63 kva to 100 kva transformer from store centre to site of work including loading & unloading at both site., earthing of each 11 kv line pole & t/f properly after drive of electrodes if size 20mmx250mm and connection the earthing point with gi wire., erection of pcc pole 8.5 mtr long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work., erection of stp pole 11 mrt long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work., fabrication and fixing of all 11 kv h.t/l.t. line accessories., erection of double pole on pcc pole 8.5 mtr/stp 11 mtr. long after digging of pit of required size including fabrication and fixing of top channel, droper channel & base channel alongwith, fixing all 11 kv accessories, fuse set 11 kv pin insulators and making connection properly., construction of new plinth for 250/400 kva as per uppcl norms, mounting of 250/400 kva t/f on plinth as per uppcl norms, providing and fixing wiremess fencing for 250/400 kva, erection/installation of following of vcb o/g in consumers site and cable joint of the panel to including earthing, grouting, anchor bolt of panel of making/repairing of pocket for cable to insert in panel form trench and fixing taping of busbar with wiring for ac,dc connection including providing ac and dc supply., chemical earthing for 250/400 kva t/f neutral and body complete, chemical earthing for vcb o/g, mounting of 10 & 25 kva t/f with proper jumping of ht side and fixing of cable on lt. side of t/f making connection properly., mounting of 63 & 100 kva t/f with proper jumping of ht side and fixing of cable on lt. side of t/f making connection properly., mounting of ct/pt unit with proper jumping of ht side and fixing of cable on lt. side of meter cubical properly, fixing of meter cubical as per uppcl norms, making a section pole to exist pole after fabrication & fixing of t channel fixing of all 11 kv accessories., erection of stay rod complete after digging a pit of size 1.20 x 0.60 x 1.6 mtr and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming., laying lifting stringing of proper sagging of acsr weasel/rabbit/dog conductor for 3 phase, 3 wire 11 kv line including binding & jumpering properly., laying lifting stringing of proper sagging of 11 kv xlpe cable of 3x70, 3x120, 3x185, 3x300 sq.mm., laying of underground 11 kv xlpe cable of 3x70, 3x120, 3x185, 3x300 sq.mm. sizes with open trench by brick & sand as per uppcl norms., filling the 11 kv jointing kit (joint kit providing by c
Tender For manufacture, testing, supply and delivery of 3 ph , 4 wire 132kv ct/pt operated and (33kv and 11 kv) and lt ct operated export-import energy meter for different bulik consumer
Tender For supply of 8-way lt panel enclosure equipped with mccbs and essential instrumentation, desi gned for 415 v ac, 50 hz operation with thermal magnetic trip units, conforming to iec 60898-1:2002. the panel shall include: incomer mccb rated 250 a, 36 ka, 4 pole - 01 no/set; outgoing mccb rated 125 a, 36 k a, 4 pole - 01 no/set; mccb rated 100 a, 25-30 ka, 4 pole - 02 nos/set; mccb rated 63 a, 25-30 ka, 4 pole - 02 nos/set; mccb rated 32 a, 25-30 ka, 4 pole - 02 nos/set. the panel shall also be fitted with a suitable pa nel-mounted digital multifunction meter (3-phase, 0-500 v ac range) - 01 no/set with cts, digital energy m eter (3-phase, 415 v ac) - 01 no/set, rybg led indicators - 04 nos/set, ct coils (250/5a) - 03 nos/set, and appropriate capacity copper bus-bars, neutral link, earth bar, spreader link, and lock & key arrangement - 01 set. the complete system shall be housed in a sheet steel enclosure of approximate dimensions 1475 mm (h) x 1400 mm (w) x 300 mm (d), fabricated from 2 mm thick crca steel, powder coated in siemens g rey. approved makes: l&t or legrand or havells or schneider or siemens or abb for switchgear. make: sec ure or l&t or schneider for meters. [ warranty period: 30 months after the date of delivery ]
Tender For implementation of lt auxiliary items for smart metering works in sikkim under revamped reforms-based and results-linked, distribution sector scheme - through main service distribution box, smc main service distribution box (msdb) for ug (10% of msdbs for 17652 consumers- 6 per msdb), smc main service distribution box (msdb) for over head (1 msdb per 6 consumers for 50% consumers), 4 core 25 sq mm xlpe cable from oh line to msdb [@ 2 meter per msdb], piercing connectors from lt ab cable (for 10587 msdbs @4 per msdb), dt cable, 4cx35 sq mm cable,1.1kv grade, xlpe insulated, armoured, frls type for 16kva, 25kva xmer [1,564 dts @ 6 meter per dtr], 4cx50 sq mm cable, 1.1kv grade, xlpe insulated, armoured, frls type for 50kva and 63kva xmer [686 dts @ 6 meter per dtr], 4x1c*120 sq mm cable, 1.1kv grade, xlpe insulated, armoured frls type for 100kva xmer [277 dts @ 6 meter per dtr], 4cx185 sq mm cable, 1.1kv grade, xlpe insulated, armoured frls type for 150kva -200kva xmer [203 dts. @ 6 meter per dtr], 2rx4cx120 sq mm cable, 1.1kv grade, xlpe insulated armoured, frls type for 250kva - 315 kva xmer [222 dts @ 6 meter per dtr], 2rx4cx240 sq mm cable, 1.1kv grade, xlpe insulated armoured, frls type for 400kva - 500kva xmer [196 dts @ 6 meter per dtr], 2rx4cx300 sq mm cable, 1.1kv grade, xlpe insulated armoured, frls type for 630kva xmer [9 dts @ 6 meter per dtr], 2rx4cx400 sq mm cable, 1.1kv grade, xlpe insulated armoured, frls type for 700kva - 800kva xmer [19 dts @ 6 meter per dtr], 2rx4cx630 sq mm cable, 1.1kv grade, xlpe insulated armoured, frls type for 1000kva xmer [53 dts @ 6 meter per dtr], sundry items such as lugs, tapes etc. for proper terminations/ ct connections etc., aluminum thimble 35 sq mm for dt meter [1,564 dts @ 8 nos.per dtr], aluminum thimble 50 sq mm for dt meter [686 dts @ 8 nos. per dtr], aluminum thimble 120 sq mm for dt meter [277 dts @ 8 nos. per dtr, 222 dts @ 16 nos. per dtr for double run cable], aluminum thimble 185 sq mm for dt meter [203 dts. @ 8 nos. per dtr, for double run cable], aluminum thimble 240 sq mm for dt meter [196 dts @16 nos. per dtr for double run cable], aluminum thimble 300 sq mm for dt meter [9 dts @16 nos. per dtr for double run cable], aluminum thimble 400 sq mm for dt meter [19 dts @ 16 nos. per dtr for double run cable], aluminum thimble 630 sq mm for dt meter [53 dts @ 16 nos. per dtr for double run cable], l.t. distribution board, ltdb 63 a, ltdb 100 a, ltdb 200 a, ltdb 400 a, ltdb 630 a, ltdb 800 a, ltdb 1000 a, ltdb 1600 a