Get complete information related to latest Ct Meter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ct Meter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ct Meter Tenders.
Tender For tender for survey supply design erection testing commissioning of h t line dtr l t lin ctpt metering unit and civil work etc to complete the work for providing sop to construction of rain water harvesting on son khadat batalkial in g p chouri sarkagh
Tender For supply of traction motor voltmeter type moving coil scale range 0-1.8 kv for wam-4 loc o to clw specn. no. clw/es/i-21/ alt-a or latest. [ warranty period: 30 months after the date of deliv ery ]
Tender For supply of auto transformer starter panel of 75 hp comprising of 160a mccb, as incomer with rotary h andle, air cooled copper wound auto transformer having variable tapping 30/50/65/80%, with 12 sec starti ng time, three nos 110 a 415 v, 80 amp and 50 a 415 v rating heavy duty power contractors with auxiliary contacts , ct operated 84.6-135a overload relay, electronic over voltage, under voltage relay,timer 1 no- 1 nc, phase failure, phase unbalanced electronic relay with under voltage and over voltage protection, earth leakage relay elr+cbct, ammeter with ct and selector switch, voltmeter with selector switch, three phas e and motor on/trip led indicators, enclosed in bolted type panel made of minimum 2 mm thick crca with pu foam gasket and with foundation channel. the complete enclosure should be in powder coating finished , with control and power wiring purchase certificate of oem / authorized dealer of oem to be submitted wit h the bill. make: bch, l&t, c&s, jyoti, schneider or equivalent make having same specification. [ warrant y period: 30 months after the date of delivery ]
Tender For corrigendum : procurement of spares of mineline private limited make flp vcb 3 3kv flp tsu 3 3kv 550v flp acb etc - isolator 400a , vacuum circuit breaker 3.3kv , potential transformer 3.3 kv , hrc ht pt fuse , primary side p.t fuse plate wiring assembly , h.t. control plate wiring assembly , voltmeter , fuse terminal , multicore bushing , indicating lamp , 3.3kv adopter , 3.3kv coupler , bullet pin 3.3kv , hv bushing , dc power pack , neutral monitoring relay with resistance , earth leakage 50 750m a and 750ma 2a dual settings , earth leakage relay 50 750m a with time lag with cbct , overload short circuit and motor protection relay , vcb aux .rotary switch , control relay , ht bushing , vcb shunt trip coil , timer , 3 pole oil dashpot relay , cover bolts , insulator assembly k3 on off , overload assembly breaker 110a 200a , overload assembly breaker 310a 400a , overload coil 200a , short trip assembly complete , shunt trip coils , no volt coil assy. under voltage coil assy. with moulding , catcher assembly , arc chutes , ammeter 200 5 for acb , ammeter 100 5 for acb , ammeter 300 5 for acb , ammeter 400 5 for acb , busbar , potential transformer , brass cone and gland assembly , indicating lamps , power cable for 300a for breaker chamber ic and og , limit switch 2no 2nc for breaker , brass terminal for cp , brass terminal with dmc insulator , terminal bushing insulator dmc incoming 10mmx25mm , on off isolator 300a , split type terminal box , on off isolator 400a , circuit breaker for 100a with complete assy. , circuit breaker for 200a with complete assy. , complete control wiring including pla relay ptds elm7 control fuses control plate wiring harness etc mounted on control plate or circuit breaker for 300a with complete assy , complete control wiring including pla relay ptds elm7 control fuses control plate wiring harness etc mounted on control plate or circuit breaker for 400a with complete assy , earth leakage 50 750m a with time lag , core balance transformer , on off isolator 100a , isolator handle , 1ph 5kva lighting transformer 550 440v sec.110v with mid point earthed , earth leakage relay , brass terminal with dmc bushing , brass stud with dmc bushing for og , magnetic ol relay , thermal ol relay , on delay timer , push button and element , isolator on off rev 100a , pilot relay , switch module , isolator on off rev 200a , on off rev isolator 300a , copper terminal bushing cp og , aux. contactor 220v ac , resistance
Tender For supply of coil for shunt trip spring release, part no.flpvcb 017 , auxilary transformer for control circuit, part no.flpvcb 023 , earth leakage relay, part no.flpvcb 024 , idmtl relay 2 oc and 1 ef with instantan, part no.flpvcb 026b , auxillary contc 3no 1nc110v coil, part no.flpvcb 028 , hrc fuse base 20a for control, part no.flpvcb 030 , epoxy resing moulded 1phase i 3.3 kv, part no.flpvcb 034 , pt fuse 3.3 kv, part no.flpvcb 035 , 72 sq mm voltmeter 0-5 kv ptr 3.3kv 110v, part no.flpvcb 037 , dmc moulded copper terminal 400a,3.3kv, part no.flpvcb 045 , h.t hex bolt for terminal chamber cover,part no.flpvcb 055 , h.t hex bolt for cablle box size m10 x 2,part no.flpvcb 056 , throughgoin g copper busbar 630a set of 3, part no.flpvcb 058 , h.t hex bolt for main lid and isolator lid, part no.flpvcb 053 , insulated cable 120sqmm trminl to incom, part no.flpvcb 070 , insulated cable 120sqmm outgong to term, part no.flpvcb 071 , shunt trip assembly with coil, part no.flpvcb 004 , solenoid operted spring release assy wi, part no.flpvcb 005 , copper net terminal, part no.flpvcb 007 , copper top terminal, part no.flpvcb 008 , copper bottom terminal, part no.flpvcb 009 , epoxy cast drive insualtor for vi, part no.flpvcb 011 , auxillary switch, part no.flpvcb 013 , 1 set spring for catch machnism for vcb, part no.flpvcb 014 , 1 set spring for drive machnism, part no.flpvcb 015 , 1 set spring for tripping drive insulotar, part no.flpvcb 016 , isolator 3.3 kv 400a complete, part no.flpvcb 018 , fibre glass link for isolator, part no.flpvcb 021 , epoxy molded cor balance transformer 3.3, part no.flpvcb 025 , magnetite ol relay comp, part no.flpvcb 026 , solid state overload and short circuit rel, part no.flpvcb 026a , under voltage relay with time delay, part no.flpvcb 027 , hrc fuse link for control, part no.flpvcb 031 , epoxy resin moulded c.t. for ammeter, part no.flpvcb 032 , epoxy resin cast c.t. for short circuit, part no.flpvcb 033 , 72 sq mm ammeterct operated, part no.flpvcb 036 , brass actuator for push button, part no.flpvcb 038 , limit switch, part no.flpvcb 040 , led lamp holder with lamp vacuum circut, part no.flpvcb 043 , jones plug 18 pin, part no.flpvcb 044 , dmc mouldled auxillary terminal, part no.flpvcb 046 , brass gland complete with stud and nut, part no.flpvcb 052 , dashpot oil for ol relay 50ml, part no.flpvcb 059 , vacuum interrupter 400a, part no.flpvcb 006 , diode based rectifier complete, part no.flpvcb 029 , micro switch for push button element, part no.flpvcb 039 , h.t hex bolt for side lid and terminal ch, part no.flpvcb 054 , m.s meter fixing plate fitted with 01 n, part no.flpvcb 057 , version, manual spring assisted type, part no.flpvcb 001
Tender For supply, erection testing commissioning of 5hp borewell submersible pump set , rated pow er 3.7kw, 3-phase,415volts, 50hz, delivery 1.66lps, discharge head 160 to 60lpm at hand of 50 to 125 me ter, as per confirming to is 8034 or latest pump delivery size 40mm dia, with suitable dol control panel c onsist of contractor, dry run,with isi marked mcb /main switch, ammeter, voltmeter and water level indicat or and single phase preventer , micro based type neatly wired in powder coated ms box. including non ret urn valve, erection clamp acceptable make: kirloskar, ksb,cri,texmo, crompton, haveels, mbh, v-guard ,oswal pumps only. [ warranty period: 12 months after the date of delivery ]
Tender For supply of insulation tester 5 kv/ insulation resistance up to 10 t ohm @5 kv, high current- 3 ma short - ci rcuit current, high noise immunity- 3 ma (5 kv), li-ion battery- up to 6 hrs continuous testing @ 5 kv with a 100 m load, battery meets iec 2133 large lcd display with backlight, dedicated voltmeter function (30 v to 660 v), similar to model : megger mit525 as per attached annexure. [ warranty period: 12 months after the date of delivery ]
Tender For supply of 250ma for mhs, maithon, dvc , potentiometer for manual voltage adjustment 10k ohm_3w for phps, panchet, dvc , potentiometer for manual voltage adjustment 10k ohm_3w for mhs, maithon, dvc , sync. transformer for scr controller unit for 150a float-cum-boost charger, 0-270- 300v_80-0-80v, 100ma for phps, panchet, dvc , sync. transformer for scr controller unit for 150a float-cum- boost charger, 0-270-300v_80-0-80v, 100ma for mhs, maithon, dvc , filter capacitor, 4700 micro farad_ 350 volt dc for phps, panchet, dvc , filter capacitor, 4700 micro farad_ 350 volt dc for mhs, maithon, dvc , blocking diode for battery charger for phps, panchet, dvc , blocking diode for battery charger for mhs, maithon, dvc , ac supply fail relay card static type 415v ac for phps, panchet, dvc , ac supply fail relay card static type 415v ac for mhs, maithon, dvc , semiconductor protection fuse, high speed, 200a for phps, panchet, dvc , semiconductor protection fuse, high speed, 200a for mhs, maithon, dvc , thyristor 150a, 1200v _h150tb12 for phps, panchet, dvc , thyristor 150a, 1200v _ h150tb12 for mhs, maithon, dvc , battery protection fuse _200 a hrc type for phps, panchet, dvc , battery protection fuse _200 a hrc type for mhs, maithon, dvc , dc voltmeter selector switch _16a, 1pole, 4 way spa3116d for phps, panchet, dvc , dc voltmeter selector switch _16a, 1pole, 4 way spa3116d for mhs, maithon, dvc , integrated dc sensing module consisting of circuit - ch. failure, dcu_ovr, befr, fbcor, sfr, auto equalise for phps, panchet, dvc , integrated dc sensing module consisting of circuit - ch. failure, dcu_ovr, befr, fbcor, sfr, auto equalise for mhs, maithon, dvc , dc power supply for idsr card _static type, 24 v and 12 v dc for 150a float cum boost charger _make_ chloride for phps, panchet, dvc , dc power supply for idsr card _static type, 24 v and 12 v dc for 150a float cum boost charger _make_ chloride for mhs, maithon, dvc