Get complete information related to latest Ct Scan Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ct Scan Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ct Scan Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :43798184 Due date: 06 Feb, 202606 Feb, 2026 NA
Tender For set of proximal femoral nail antirotation-ii (long/short),two locking bolt , one helical blade, interchangeble sizes specifications : 1. should be made up of titanium , 2. system should have head screw locking mechanism as well as on table dynamic fracture compression mechanism. 3. should supply all implants and instrumentation of various sizes at the time of surgery. 4. it should be mri compatable. bis/european ce/usfda approval (certificate to be attached with the offer.

CTN :42579205 Due date: 13 Feb, 202613 Feb, 2026 NA
Tender For corrigendum : supply of schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.) - schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.), polyster base round corner x-ray films (8" x 10") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (10" x 12") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (12" x 15") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, dental x-ray films intraoral periapcal the density values should blue base with base fog less than or equal to 0.20 & dmax not less than 3.10 the density values should be met at developer temperature 32 c to 35 c, liquid developer replenisher for automatic processor (starter solution, if recommended by the manufacturer, should also be supplied), ( price of item no. 5 and item no. 6 will be considered as a unit), liquid fixer hardner for automatic processor ( price of item no. 5 and item no. 6 will be considered as a unit), inj. meglumine diatrizoate sodium diatrizoate iodine content 365-375 mg/ml in 20 ml. ampoule/vial, pigtail angiography catheter with multiple side holes length 65 to 75 cm 5f, inj. gadolinium based contrast for mri for liver/liver specific (should provide details of compound being hepatobiliary specific), inj. gadolinium based contrast for mri for general use, inj. gadolinium based contrast for mri for angiography, disp lure lock syringes 3 ml. for glue injection, disp lure lock syringes 1 ml. for glue injection, x-ray folders laminated 250 gsm 14 1/2" x 17 ", dual pack 200 ml syringe with aspirator, "y" shaped coiled tube y-tube sterile, non-pyrogenic (minimum 300 psi & above) compatible with dual head pressure injector ( lf/medrad/ sea crown / spectra / apollo), extension "y" shaped coiled tubing for injector 150 cms. (-5 or +15cm) low pressure (minimum 300 psi & above), dual disposable syringes (60 to 65 ml each) with "y" or "t"shaped coiled tube connecting tubes small spike for contrast and large spike for saline compatible with mri injector (lf or medrad)., one way stopcock (high pressure), low pressure extension "y" or "t" shaped coiled tubing min. 150cms (-5 or +15 cms) with coiled connecting tubes & small spike for contrast & large spike for saline for medical mri injector., flavoured, ionic, water soluble, oral contrast iodine content 240-250 mg/ ml. in 30 ml, bernstein catheter 4 f 100 cm, bernstein catheter 5 f 100 cm, chiba needle 21 g 15 cms length, chiba needle 22 g 15 cms length, disposable c t scan pressure injector syringes (190 ml syringe + quick fill tube) for bayer medrad salient injector (toshiba / canon), extension "y" shaped coild tube adapter dual check valves (minimum psi 300 & above), nonionic iodixanol isoosmolar, 320 mg 50 ml, disposable mri syringes kit for 65/115 mr injector system 65 ml contrast syringes and 115 ml ns syringes with connecting tubing combo pack for spectris solaris medrad pressure injector, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 14 g & 10 cm in length, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 16 g & 10 cm in length, coil shape breast tissue marker with both front trigger & an alternate rear trigger, should be visible in ultrasound, mammography and mri, extension coiled tube with integr

CTN :43379498 Due date: 02 Feb, 202602 Feb, 2026 NA
Tender For corrigendum : supply of mri 3t scan system

Central Government/Public Sector

CTN :43481521 Due date: 05 Feb, 202605 Feb, 2026 NA
Tender For corrigendum : cardiac mri t1 and t2 mapping and up gradation of existing system to mr 750w 30.1 platform

CTN :43709002 Due date: 07 Feb, 202607 Feb, 2026 11.07 Lacs
Tender For supply of nitrous gas , cylinder co2 gas for , cylinder oxygen o2 gas , cartidge hp 416 for color laser jet enterprise mfp m 480hp , cartidge 166 a for hp laser mfp1188nw printer with mri , bayer disposable mri kit 65 115 mr injector system

Central Government/Public Sector

CTN :43580184 Due date: 10 Feb, 202610 Feb, 2026 NA
Tender For corrigendum : supply of "9.4 tesla horizontal bore mri system with petscanner (insert/stand-alone) for small animals", "9.4 tesla horizontal bore mri system with petscanner (insert/stand-alone) for small animals with turnkey project"

CTN :43654776 Due date: 12 Feb, 202612 Feb, 2026 NA
Tender For supply of 3 tesla mri conditional combo-device crt-d (df-4) with quadripolar lv lead &accessories: 1. pacing mode - dddr, ddd, ddir, ddi, ddt, door, vdd, vvir,vvi, vvt, voo, ovo, voor, aai, aair, aat, aoo, oao, aoor. 2. should becapable to have anti trachycardia pacing (atp). 3. should deliver shock with 35 joules. 4. endocardial electrodes; a) right ventricular with shock coils. (i) steroid eluting or coated electrode.(ii) polyurethane & (iii) must be negotiated with 7f or less pli in size. b) atrial: (i) steroid eluting or coated electrode. (ii) screw in. & (iii) thin enough to negotiate with 9f pli or less ion size. c) left ventricular electrode with delivery system: (i) over the wire with both stylet and guide wire deliver and (ii) very thin around 4f in size to be lodged in post-lateral vein in coronary sinus. 5. epicardial electrode: to be given if endocardial lv is not possible. 6. delivery system should include a hemostatis valve b. peel away guiding catheter and wire with an option to choose from different curves caths and venogram apparatus. 7. must be supplied with all necessary compatible plis along with fluoroscopy tube covers. 8. must have at least 6 yrs. of full warranty on ipg provided by the parent company. 9. the oem must have registered office with service personnel available round clock

CTN :41826591 Due date: 23 Feb, 202623 Feb, 2026 25.00 Crore
Tender For corrigendum : project for supply, installation, operation and maintenance of 01 no. 3.0 tesla mri machine system along with providing investigation related services on revenue sharing basis on ppp mode for member secretary, rmrs, pbm, bikaner

State Government

CTN :41524390 Due date: 18 Feb, 202618 Feb, 2026 3.70 Crore
Tender For corrigendum : technical specification point wise dbs implant & accessories - dbs rechargeable with directional lead with25yr battery life & image guided programming integrated inside clinician programmer with micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers, usfda & ce approved kit contents: rechargeable pulse generator-1 , directional lead kit -2 , extension kit -2 , burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1, patient charging kit -1 , dbs rechargeable with non directional lead with 25yr battery life & image guided programming integrated inside clinician programmer micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers. have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage, usfda & ce approved kit contents:rechargeable pulse generator -1, non-directional lead kit -2, extension kit -2, burr hole locking kit -2, tunneling tool -1, patient remote control kit -1, patient charging kit -1, dbs non rechargeable with directional lead with image guided programming integrated inside clinician programmer micc multiple independent current control technology &bluetooth connectivity with clinician and patient programmers,usfda & ce approved kit contents: non-rechargeable pulse generator -1 , directional lead kit -2 , extension kit -2, burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1,), dbs non rechargeable with non-directional lead with image guided programming integrated inside clinician programmermicc multiple independent current control technology withbluetooth connectivity with clinician and patient programmers. should have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage,usfda & ce approved kit contents: non-rechargeable pulse generator -1, non-directional lead 1), dbs implant kit with non-rechargeable, 3t mri compatible and sensing enabled ipg and directional leads.the implanted pulse generator (dbs neurostimulator- ipg) should have a minimum service life of 5-7 years and there should not be a need to recharge it periodically.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the leads should be able to stimulate in specific directions, in addition to the ability to stimulate circumferentially. markers on leads should facilitate directional programming even if lead rotates. the leads should also be able to sense lfps.burrhole kit should be there for securing lead in place. microelectrodes for intra op stimulation and recording should be there.the extension connecting the lead and ipg should be flexiblethere should be a tunneller to place the extension wire and the tunneller should be metallic and firm to enable smooth tunnelling.the system should have approval for conditional full-body 1.5t & 3t mri compatibility.patient programmer, enabling the patient to see and if needed, modify the stimulation under guidance, should be available. patients should be able to mark dyskinesia, tremor etc. using the programmer., dbs implant kit with rechargeable, 1.5t & 3t mri compatible and sensing enabled ipg and directional leads.the implantable pulse generator (dbs neurostimulator- ipg) should have a service life of 15+ years if regularly recharged by the patient at specified intervals.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the system shou

Central Government/Public Sector

CTN :43211808 Due date: 09 Feb, 202609 Feb, 2026 NA
Tender For supply of mri conditional crt d system