Get complete information related to latest Current Regulator Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Current Regulator Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Current Regulator Tenders.
Tender For corrigendum : supply of aux contact 2 no as per clw spec no. clw/es/0096 alt -g for scheider make mcb 3-pole 63,40,16 amp.electric type rep-19071 [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of contractor for net 1 & 2 , rated voltage 1000v ac. rated kva 100 at rated voltage & 70 deg. c and utilization category 6a, main pole 4. aux. contact 2 no+2nc, control voltage 415 a ac with surge suppressor, suitable for feeder contractor for nct 1 & 2 item code s 1k01 & s 1ko2, accepted make- schneider. abb, siemenes and l&t, only, confirming to rdso/pe/spec/ac0192-2018 (rev.1) as per letter no.eu7.1.108/mssbc dated 17.09.2021. [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of air circuit breaker(acb) suitable for lhb power car of system voltage-750 v , capacity-800 amp , breaking capacity - 50ka , frequency- 50 hz, 3 pole mf( with inbuilt uv protection , thermal ,magnetic release, 6 no+ 6 nc aux contact block and draw-out acbs terminal adaptors) similar to l&t make acb type : cn-cs 800c conforming to rcf specification no : edts 103 , rev-d, am-07 or latest, make- l&t/abb/ge. [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of contactor 4 pole, rated voltage 1000v ac, rated kva 100 at rated voltage, control voltage 415v ac with 2no + 2 nc aux. contact & surge suppressor used for feeder contactor net 1 & net 2 in lhb type ac coaches as per rdso common bill of material letter no. el/7.1.108/mssbc dated 17/9/2021, annexure column no.1, sr. no. 3 conforming to column no.7. make: schneider/abb/siemens/l&t. [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of contactor for 60 kva transformer, rated current:95 amps, rated voltage: 690 v ac, main pole:4, with aux. contact: 1 no+1 nc, control voltage: 230 volts ac ( 168 volts ac - 300 volts ac means +/- 30% ) with add on auxiliary contact block and surge suppressor.
Tender For supply of contactor,3pole,3ph,32a,415v ac with 110 v ac coil as per bch cat no.ce15fn3ab with aux contact cat no-c320kgtc22 (2no+2nc front mounting) or equivalent in same spec,size & dimension of siemens/abb/ schneder make for sgac coaches conforming to rdso spec. no.rdso/elps/spec/ac/04 (rev.3) amnd no.1 feb-2010. [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of contactor with diode for ventilation fan unit current rating 16 amp,voltage rating 690 v ac, main pole 3 no. aux contact 1 nc control voltage 77-143 vdc with surge suppressor. makes as per bom sl.no 58 of letter no. el/7.1.108/mssbc dt.- 17- 09- 2021 i. e abb (tal16-30-10+rv5/250) schneider (lc1d18fd), siemens (3rt20181bf42+3rt29161jl00), l&t(mdx25)only. [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of lt circuit breaker at vindhyachal and allahabad substation e e - supply of 415v 3400a 75 ka 3-pole ac lt air circuit breaker and accessories for retrofitment as per attached ts and sow , retrofitment kit with copper bus thickness 8mm width 10cm for supplied acb , retrofitment of new lt air circuit breaker in acdb including dismantling of old circuit breaker , spring charging motor , aux. contact sets , bus bar seal off insulators , arc-chutes , moving contacts , arcing contacts fixed moving , springs closing opening , closing coil with resistor , tripping coil with resistor , supply of 415v 1000a 3-pole ac lt air circuit breaker and accessories for retrofitment as per attached ts and scope of work , supply of 415v 800a 3-pole ac lt air circuit breaker and accessories for retrofitment as per attached ts and scope of work
Tender For supply of mcb of siemens make of rating 4p 415v ac50hz 2a 10ka c curve , mcb of siemens make of rating 2p 440v dc 4a 10ka c curve , mcb of siemnes make of rating 2p 415v 10a 10ka c curve , mcb of siemens make of rating 2p 415v 6a 10ka c curve , mcb of siemens make of rating 2p 415v 4a 10ka c curve , mcb of siemens make of rating 2p 415v 16a 10ka c curve , mcb of siemens make of rating 3p 10a 10ka c curve , mcb of seimens make of rating 2p 2a 415v ac 10ka c curve , mcb of seimens make of rating 2p 25a 415v ac 10ka c curve , mcb of seimens make of rating 2p 440v dc 6a 10ka c curve , mcb of seimens make of rating 415v 6a 2p 7.5ka c curve , mcb of seimens make of rating 415v 10a 2p 7.5ka c curve , mcb of seimens make of rating 415v 4a 2p 7.5ka c curve , mcb of seimens make of rating 415v 16a 2p 7.5ka c curve , auxiliary contactor of seimens make of rating 10a at 230v ac 50hz 3no1nc coil 220v dc , auxiliary contactor of seimens make of rating 10a at 230v ac 50hz 2no2nc coil 110v 50hz ac , auxiliary contactor of seimens make of rating 4a at 400v ac 50hz 2no2nc contacts coil 110v ac , power contactor of seimens make of rating 9a at 415v ac 50hz 3 power 1nc add on block4 no , power contactor of seimens make of rating 25a at 415v ac 50hz 3 power 1no1nc coil 230v 50hz ac , power contactor of seimens make of rating 40a at 415v ac 50hz 3power1no1nc coil230v 50hz ac , power contactor of seimens make of rating 25a 3p 230v ac coil supply 50hz inbuit aux. contact 1no1nc with add on 2no2nc , power contactor of seimens make of rating 12a 3pole power contactor coil110v 50hz inbuit aux. contact 1no inbuilt and add on 2no2nc aux. contact , mpcb of seimens make of rating 3power 1no1nc 415v add on c1 c2 aux. 1no1nc , mccb of seimens make of rating 415v ac 50hz 4 pole 160n in25a set at 18amp. with 1 c.o aux. contact