Get complete information related to latest Cyclic Voltammetry Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cyclic Voltammetry Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cyclic Voltammetry Tenders.
Tender For supply of machinery/tools for various parks at pul pehladpur ward no. 179 in central zone - brush cutterengine: single cylinder, 2 stroke, aircooled onlyengine displacement: 40.2ccpower output: 2kw/2.7hp max output shaft speed at cutting attachment: should be minimum 9000 rpmcarburetor: diaphragm with compensator technology.fuel tank capacity: minimum 600 ml. weight( dry,without cutting attachment & deflector): should not be more than 7.5 kgclutch: centrifugal type, clutch shoe support base & lining metal only. multi function handle: should have acceleration ,on/off switch at right handle. brushcutter harness: should be double shoulder harness only. anti vibration system: must have 4- point aniti vibration system. vibration level in m/s2 at right handle : should not be more than 2.5 m/s2 sound pressure level db(a): should not be more than 105 db(a) drive shaft design: must have drive shaft ends square design type only. certification : must have valid en certificaton, petrol operated pole prunnerengine : single cylinder, 2 stroke, air cooled onlydisplacement: should be between 25-30 cc power output : should be minimum 1.2 hpweight (dry without cutting attachment & fuel ): should not be more than 7.5 kgfuel tank capacity (ml): should be minimum 400mlchain oil capcity (ml): must have minimum 200 ml.clutch : clutch shoe linining should be metal only.guide bar length : minimum 30cm guide bar and chain : should have same manufacture only .chain type : every drive link need groove & small oil holes for better lubrication. saw chain pitch should be 1/4" or 3/8picco only and drive link thickness must have 1.1 mm or 1,3 mm.max.output shaft speed (rpm): should be minimum 8000 rpm at chain sprocket.equipment total length with guide bar and chain ( cm ) : should be mimimum 220 cm - compressed & total length of equipment - minimum 350 cm - extended. sound pressure level (db/a): should not be more than 95 db(a)vibration measurement m/s2 at control handle - extended poistion : should not be more than 5.5 m/s2certification : must have tuv certification with test standard en iso 11680., hedge trimmerengine: 2- stroke - single cylinder air cooled.engine displacement: should be between 20-25 ccpower output: should be minimunm 1 hpfuel tank capacity: minimum 400 mlweight: should not be more than 6.0 kgclutch: clutch linning should be metal only.handle: must have rotating multi-function handleanti vibration system: must have spring loaded technology for anti vibration system design: should have double sided blade with tooth spacing minimum 35mm bar length: minimum 600 mmblade: should have chrome plated -anti corrsion. stroke rate ( l/min): minimum 3000 vibration level m/s2 at right handle: should not be more than 3.5 m/s2.sound pressure level (db..(a)): should not be more than 95certification: should have tuv with en iso 10517:2009, lopperanvil tree branch lopper lade material - high carbon steel with hard surface treatment, overall length - not less than 914 mm handle material - similar materil as per requirement, weight - 1.5 kg., cutting dia - not less than 38mm
Tender For providing of calibration services - annual calibration of 240-ch structural dynamic test & measurement system for 2 years, mechanical; structural dynamics test & measurements; nabl labs; buyer premises (onsite),calibration services - annual calibration of 128-ch structural dynamic test & measurement system for 2 years, mechanical; structural dynamics test & measurements; nabl labs; buyer premises (onsite),calibration services - annual calibration of 12-ch scadas xs compact system for 2 years, mechanical; scadas xs; nabl labs; buyer premises (onsite),calibration services - annual calibration of single axis accelerometers model no 352c33 - 10 nos for 2 years, mechanical; speed & acceleration; nabl labs; buyer premises (onsite),calibration services - annual calibration of tri-axial accelerometers model no 356a02 - 10 nos for 2 years, mechanical; speed & acceleration; nabl labs; buyer premises (onsite),calibration services - annual calibration of dc accelerometers model no 3741 series - 10 nos for 2 years, mechanical; s
Tender For corrigendum : purchase of equipments - purchase of equipment, 1. configuration design an 8-channel battery analyzer and its accessories 2. power 425 w3. voltage measuring range: 25 mv to 5 v, discharge minimum voltage: 0v or better, accuracy: 0.05% of fs4. current range: 0.5 ma to 6 a, accuracy: 0.05% of fs or better 5. power per channel output power: 30w, stability; +/- 0.1% of fs or better6. time rise time: 1ms (0~full range)7. frequency 10hz8. charge mode of operation: cc, cv, cccv, cp end conditions: voltage, current, relative time, capacity.9. discharge mode of operation: cc, cv, cp, cr, end conditions: voltage, current, test time, capacity, energy.10. pulse mode charge: cp mode, cc mode, discharge: cc mode, cp mode, min pulse width: 500ms, automated switch: automated switch from charge to discharge for each pulse end condition: voltage, relative time11. dcir support for the calculation of the point of the dcir12. cycle cycles: 1 65500 or better, steps: 250 or better, nested function: max three levels of loops13. protective function software, power-down data protection, user-defined safety (upper and lower) tolerance of current, voltage, and delay time14. channel features independent pairs of closed loops for the constant current source and constant-voltage source15. test reports and curves for analysis different types of curves created by software based on user definition. (voltage-time curve, current-time curve, capacity-voltage curve, loops times charge/discharge capacity curve, loops times charge/ discharge efficiency curve, etc.), data reports created by the software. comparison of the performance of the batteries tested in channels, both visually and statistically16. channels independent control17. ac input ac 220v 10% / 50hz 18. voltage and current testing sample 4 wire connecting 19. noise 85db20. data management mysql database21. communication means tcp/ip protocol22. data output excel, txt23. communication interface ethernet port24. number of channels per cabinet 825. accessories: 1. bi-potentiostat: electrochemical workstation or moduletechniques the system should be capable of running the rde / rrde technique simultaneously cyclicvoltammetry (cv) with simulation/fitting programs linear sweep voltammetry (lsv) with stripping bulk electrolysis with coulometry (be) differential pulse voltammetry (dpv) with stripping normal pulse voltammetry (npv) with stripping tafel plot (tafel), potentiodynamic deactivation, pitting corrosion, corrosion rate, linear polarization, corrosion current, etc. multi-current steps (istep) amperometric i-t curve (i-t) lifetime testing open circuit potential time (ocpt) chrono amperometry (ca) chrono coulometry (cc) chronopotentiometry with current ramp (cpcr) potentiometric stripping analysis (psa) auxiliary signal measurement channel ir compensation external potential input galvanostatic charge discharge single/multiple cycle -chrono potentiometry (cp) with potential limits, polarity by potential or time, no. of cycles etc. voltage vs current density curves single or multiple potential steps with charge limits, single or multiple current steps, mixed voltage/current control using macro. i-v measurements, i max, pmax, fill factor, etc.impedance ac impedance (imp) 10 hz to 3mhz impedance time (impt) (mott-schottky) impedance potential (impe) impedance simulator with fitting open circuit potential time (ocpt)hardware specification of bi-potentiostat workstation/ module: potentiostat / galvanostat module, 2- or 3- or 4-electrode configuration maximum potential: 10v, maximum current: 250 ma peak or better and 2 amps with +/-25 volts for higher current measurement. compliance voltage: > 13v or better, potentiostat rise time: 300 ns or better galvanostat applied current range: 3na to +/- 100ma or better and upto 2 amps applied current accuracy: 20 pa or better input bias current: 1 pa or better cv and lsv scan rate: 0.000001 to 10,000 v/s. ca and cc pulse width: 0.0001 to 1000 sec imp freque
Tender For supply of vacuum oven with pump,vacuum oven with pump,vacuum oven with pump,potentiostat/galvanostat with necessary accessories,potentiostat/galvanostat with necessary accessories,potentiostat/galvanostat with necessary accessories,portable cyclicvoltammetry/ charge and discharge system,portable cyclicvoltammetry/ charge and discharge system,portable cyclicvoltammetry/ charge and discharge system
Tender For supply of various size & types of rtds for 3x210 mw unit 3,4 & 5 at gandhinagar tps. - duplex rtd pt-100 as per gtps drg no ext-inst-00434 for unit no 3 and 4 id fd pa fan and motor and coal mill motor de nde bearing temperature measurement system., solid sintered tungustan carbide thermowell, length 325 mm, process conn. m 33 x 2 (m), inst conn. 1/2 inch bsp (f) for coal mill out let temperature as per drg. no.gtps/ext- imd-ii -00713, rtd duplex 3 wire pt-100 for coal mill outlet temp, od 6 mm,ss 316 sheath material insulation compact filled mgo insertion length 450 mm end connection 1/2 inch bsp head die cast aluminium ip 65.ext, pipe 150 mm., rtd, pt-100, duplex, 3 wire mineral insulated (compact mgo filled) without head (head less), sheath dia: 6 mm, sheath length: 60 mm., rtd, pt-100, duplex, 3 wire mineral insulated (compact mgo filled) without head (head less), sheath dia: 10 mm, sheath length: 300 mm straight., rtd, pt-100, duplex, 3 wire mineral insulated (compact mgo filled) without head (head less), sheath dia: 12 mm, sheath length: 100 mm straight, cable length: 15 meters., rtd, pt-100, duplex, 3 wire mineral insulated (compact mgo filled) without head (head less), sheath dia: 8 mm, sheath length: 25 mm., rtd, pt-100, duplex, 3 wire mineral insulated (compact mgo filled) without head (head less), sheath dia: 12 mm, sheath length: 250 mm straight, cable length: 20 meters., rtd, pt-100, duplex, 3 wire mineral insulated (compact mgo filled) without head (head less), sheath dia: 12 mm, sheath length: 250 mm straight, cable length: 10 meters., rtd, pt-100, duplex, 3 wire mineral insulated (compact mgo filled) without head (head less), sheath dia: 12 mm, sheath length: 350 mm straight, cable length: 10 meters., rtd, pt-100, duplex, 3 wire mineral insulated (compact mgo filled) without head (head less), sheath dia: 08 mm, sheath length: 250 mm straight, cable length: 10 meters., headless rtd(pt-100type) for f.d.fan of gtps unit no 5-d.e. /n.d.e. bearing temperature measurement,sheath dia. 8 mm, sheath length: 180 mm, process connection (male): dia:17.5mm thread:1.0 mm pitch 15 mm with adjustable sewage lock type., headless rtd (pt-100 type) for turbine,boiler and balance of plant services temp measurement,sheath dia. 5 mm, sheath length: 300 mm, process conn: -18 od x thread 1.0 mm pitch length 12mm with adj.sewage lock type, headless rtd (pt-100 type)for c/m o/l shaft low radial brg, warm shaft radial brg, o/l shaft brg temperature measurement, sheath dia.5.5 mm, sheath length: 432 mm,process connection:1/2 inch bsp (m) thread 14g with adj. sewage lock type, headless rtd for ce pump journal brg, cw pump thrust / general brg temp measurement, sheath dia.4.5mm,process onnection:1/2 inch bsp (m) with adjustable sewage lock type,sheath length:200 mm,, rtd pt-100 with thermowel element : is:2848,duplex /ungrounded t/w construction straight , material : solid tungusten carbide process conne: screwed m 33 x 2, ss316 t/w insertion lenth ( l1) 325 mm t/w od :22 mm, rtd (pt-100 type) for coal mill of gtps unit no 5-upper radial bearing temperature measurement, and dimension and material of construction as per drg. no: gtps / ext / c and i / 00775., head with plug and socket type temperature element pt-100 rtd for bearing temperature of high speed shaft coupling side, insertion length 170 mm., head with plug and socket type temperature element pt-100 rtd for lower bearing temperature of low speed shaft, range: 0-100 dec c, insertion length 290 mm., head with plug and socket type temperature element pt-100 rtd for lower bearing temperature of medium speed shaft, range: 0-100 dec c, insertion length 365 mm., head with plug and socket type temperature element pt-100 rtd for upper bearing temperature of medium speed shaft, range: 0-100 dec c, insertion length 700 mm., head with plug and socket type temperature element pt-100 rtd for upper bearing temperature of low speed shaft, range: 0-100 dec c, insertion length 1380 mm.
Tender For corrigendum : purchase of biomechanical equipments - nord board, it should be portable and should have 2 load cell sensors per unit with easy to attach hooks pivoting 360 degrees joint improving sensor accuracy it should have knee position indicator for replication of test position in each time. should have sample rate per sensor: upto 400hz, capacity per sensor: 100 kg/980-1000n safe over load per sensor: 150kg/1500n, max over load per sensor: 200kg/ 2000n, resolution: 1n and sensitivity: 22.0+/-mv/v. should have rechargeable battery & battery life should be100 active hours approx. should have working temperature range 5-40 c. (all weather proof) latest upgradable software should have both wired & wireless connectivity connectivity through usb (wired) bluetooth low energy (ble) for ipad & iphone i.e. (wireless connectivity) should provide 4 years warranty on hardware,should be provided with latest upgradable software and free software updates. should have software available in mobile & laptop (desktop) application with cloud analytics platform applications. should have ability to collect data both local i.e. laptop and on ios devices. local software:- for data collection & data analysis locally. cloud software:- for athlete data management and analysis. local (desktop /laptop) software should be compatible with windows 10 desktop applicationios 13 or later application (ipad & iphone). should have ability to collect data of over 10000 athletes or more to choose with simple name search / grouping them. cloud analytics platform for analysis. software (application) must give real time feedback of testing. license must be valid for 4years. cloud software: - should automatically sync all data collected on local mobile and laptop application when connected to internet.o should have a dashboard to see overview of organization s athletes data and different tiles(data indicators) to see athletes within and outside threshold zones. report section:- should have port section to able to compare different groups/athletes on longitudinal data. should have ability to compare same athlete s data over the period. athletes profile:- should have functionality to enter anthropometry (i.e. upper body & lower body measurement). athletes profile should be auto sync to local application and flexibility to move across different groups or teams with in organization and functionality to pick any athlete from large pool (1000 or more athlete). should be able to setup different access to different people i.e. to physiotherapist, sports scientist and s&c trainer within the organization to secure data access.api integration:- should have open-source api code for integration into athlete management system to integrate in ams system. should have software license valid for 4years. wi-fi tablet 64gb, space grey-1year warranty (as provided by oem) - service by customer service of oem only.hsn:8471.training for installation and demonstration shall be provided at olympian balbir singh senior international hockey stadium, sector- 63, mohali, punjab., electromyography (open), the system should be supplied with minimum 16 high speed wireless emg channel with built in imu sensor. should have analog+ digital base station should have analogy output option to facilitate integration with third party hardware and software sensor should have fixed inter sensor delay of 0.5 milliseconds or less sensors should have fixed spacing between electrodes preferably less than 15 mm to avoid motion artifacts and cross-talk sensor contacts should be made up of a metal for better contact and better-quality signal should be supplied with a charging/transmitting station that communicates with sensors to get information on their charging, recording and signal strength sensors, sensor skin interface, cable, power adapter and accessories sensors facilitate emg and imu measurements emg data analysis software for stand-alone usage with live recording of at least