Web Analytics Made Easy - StatCounter

Cyclone Separator Tenders

Get complete information related to latest Cyclone Separator Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cyclone Separator Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cyclone Separator Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :41011550 Due date: 29 Jul, 202529 Jul, 2025 NA
Tender For supply of nano fluid specific heat capacity apparateus : : - wave length range , spectral bandwidth , wave length setting , wave length accuracy , wavelength repeatability , wave length slew rate , wave length scanning speed , lamp interchange wavelength , straylight , photometric system , photometric range , photometric accuracy , photometric repeatability , baseline stability , baseline flatness , noise level , measurement method , working fluid compatibility , measurement range , sensors , calorimeter vessel , digital electronics balance , venturi meter , pitot tube

Central Government/Public Sector

CTN :41019280 Due date: 21 Jul, 202521 Jul, 2025 NA
Tender For procurement of operational spares of neelam mol at neelam platform-, castle nut , constant level oiler , cylindrical pin , cylindrical pin , cylindrical pin , external tab washer mb11 , external tab washer mb12 , fan hood , fan impeller (244/33x41) , flat gasket , flat gasket , gasket , gland ring 98/208x 30 , intermediate shaft , journal bearing , level indicator , level indicator , lubricating ring , lubricating ring 180/200x16 , lubricating sleeve , o ring , o- ring (nitro) , sealing gasket , sealing gasket , serrated lock washer , taper pin with ext. thread , ball bearing , angular contact , taper pin with ext. thread , grating , tee , castle nut , accumulator(28 ltr), accsys02774 , air in cooler , hand operated pump with inbuilt nrv & st , check valve- welded bonnet type , coil guard assy , cooling coil , cyclone separators(seal plan api p-31) , pr.gauge with gauge saver, pgsys02774 , temp.gauge with thermowell, tgsys02774 , half coupling , cartridge assembly

CTN :40969991 Due date: 25 Jul, 202525 Jul, 2025 11.21 Lacs
Tender For annual maintenance contract of two sets fired tube oil fired boilers with cyclone separator from any parties as per specification enclosed with the tender documents

State Government

CTN :40985784 Due date: 28 Jul, 202528 Jul, 2025 2.50 Crore
Tender For purchase of recovery and rejuvenation lab. - infrared sauna tower irradiance: 55-110 mw/cm2, providing therapeutic benefits rated power: 100-240v ac, 2 amp, 50-60hz, suitable for standard electrical outlets wattage: 350w, combining red light and near-infrared therapy wavelength: 650nm (red light) and 850nm (near-infrared), promoting healing and relaxation led arrays: 70 red light leds (650nm) and 70 near-infrared leds (850nm), ensuring optimal coverage variable optics: 7 60-degree optics for maximum impact and quicker results. emf emissions: no detectable emf emissions at 10-15cm, prioritizing user safety. infrared sauna units with below mentioned features to be preferred- heaters: full spectrum heaters (400w each) or carbon fiber heaters (up to 2160w total power) temperature control: digital temperature and time control for customizable sessions materials: canadian hemlock wood or western red cedar, known for durability and hypoallergenic properties additional features: bluetooth connectivity, chromotherapy lights, and built-in stereo speakers for an enhanced experience. energy efficiency: reduced electricity consumption for cost-effective use temperature range: operating temperatures between 115 f and 140 f for comfortable sessions safety features: person-specific designs and low emf emissions for safe use, cryotherapy chamberwhole body cryo therapy chamber that runs completely on electricity without need of liquidnitrogen low temperatures within the range: -130 to -140 degree celsius. multiple treatment options electric mechanical lift system ensures user s head is outside the chamber to prevent exposure to cryogenic temperatures. real-time skin temperature monitoring using ir tech sensors ensuring safe and controlledcooling. smart software that manages the treatment processes throughout each session. simple quick plug-and-play set up without requiring specialized ventilation. large uhd touchscreen for easy operation and control. at least 3 media monitors for displaying media content. hifi speakers for audio entertainment and ambient audio. work on normal indian 220v at 16a or less, whole-body pneumatic lymphatic drainage machine:key features- multi-chamber design: multiple chambers that inflate and deflate in sequence to mimic manual lymphatic drainage- adjustable pressure: adjustable pressure settings to accommodate different patient needs and comfort levels- programmable treatment: programmable treatment protocols for customized therapy sessions- user-friendly interface: intuitive interface for easy operation and programming- input voltage: ac110v/220v- power consumption: less than 400w- screen: 8-inch wide color touch screen- air pressure: 20-360 mmhg (max pressure 37.5kpa)- cooling device output temperature: 5 to -16 c- output vacuum pressure: 0-110kpa- default time: 0-60 minutes- fuse size: f3al250v- ambient temperature: 5 c to 42 c- number of air bags: 24 bags or 16 pairs atleast - treatment modes: 4 modes atleast - intensity levels: 3 levels- package size: 62x42x31cm approx - gross weight: 15 kg approxsafety features- automatic pressure adjustment: automatic pressure adjustment to prevent excessive pressure and ensure patient comfort- emergency stop: emergency stop feature to quickly deflate chambers in case of discomfort or distress- patient monitoring: optional patient monitoring capabilities to track vital signs and treatment responseadditional features- multiple treatment modes: multiple treatment modes for different conditions, such as lymphedema, edema, and post-surgical swelling- data logging: optional data logging capabilities to track treatment parameters and patient progress- portability: optional portable design for increased flexibility and convenience.certifications: ce or fda clearance, percussion massager (gun massager)key features- percussive action: a percussive action that provides rapid and repetitive strokes to muscles and tissues- adjustable speed: adjustable speed settings to customize the mass

CTN :40911531 Due date: 21 Jul, 202521 Jul, 2025 2.00 Lacs
Tender For painting of chimney of boiler ,cyclone separator, foundation of boiler and 02 nos. storage tank cap 30kl. in this factory at boiler house

State Government

CTN :40841890 Due date: 18 Jul, 202518 Jul, 2025 NA
Tender For supply and installation of laboratory equipment experimental setup for fyimp ug practical classes at the department of physics, gauhati university - laboratory equipments/experiment set ups, experiment name: to verify the law of malus for plane polarised lighttechnical specifcations:i. light source: - led: 532 nm or 635 nm ( 2 nm stability), 1 5 mw adjustable output. - unpolarized (extinction ratio >500:1). - collimated beam (divergence 0.5 mrad); qty-1ii. polarizers- glan-thompson or polymer film. - extinction ratio 10 :1 @ operating wavelength.- mounted in 50 mm rotation holders.; qty-2iii. rotation stage- motorized analyzer rotation (0.05 resolution). - accuracy: 0.1 . - range: 0 360 (continuous).; qty-1iv. photodetector- silicon photodiode (400 1100 nm). - linearity: r 0.999 (0.1 w 5 mw).- digital readout: 0.1 w resolution.; qty-1v. optical bench-- anodized rail ( 60 cm) with kinematic mounts. - vibration-damping feet.; qty-1, experiment name: to determine thespecific rotation of sugar solution using polarimetertechnical requirementsa.core instrumenti. light source- - sodium d-line (589.3 nm) or tunable led ( 2 nm stability). - output stability: 0.2% drift/hour.ii. polarizer/analyzer- glan-thompson prisms or high-grade polymer film. - extinction ratio 10,000:1 at 589 nm.iii. rotation stage- motorized with 0.001 resolution.- accuracy: 0.005 .- range: -90 to +90 .iv. sample cell-- borosilicate glass tubes with precision ground ends. - path lengths: 0.5 dm, 1.0 dm, 2.0 dm ( 0.01 dm tolerance). - temperature-controlled jacket (5 50 c 0.1 c).v. detector- photomultiplier tube (pmt) or low-noise photodiode. - linearity: r 0.999 over 0.1 w 5 mw rangevi. enclosure- light-tight with vibration damping. - internal black anodized surfaces.b.measurement specificationsi. specific rotation: range: -180 to +180 resolution: 0.001 accuracy: 0.01 ii. concentration-range: 0.01 0.5 g/ml (sucrose in water) detection limit: 0.001 g/mliii. temperature control-stability: 0.1 c at 20 c (standard condition), experiment name: to determine the wavelength and velocity of ultrasonic waves in a liquid (kerosene oil, xylene, etc.) by studying the diffraction through ultrasonic gratinga.core componentsi. ultrasonic generator- - frequency range: 1 10 mhz ( 0.1% stability). - adjustable output: 0 50 w. - digital display (resolution: 0.01 mhz).ii. transducer- piezoelectric (pzt) crystal, resonant at 2 5 mhz. - liquid-coupled design for efficient energy transferiii. liquid cell- optical glass (low thermal expansion). - dimensions: 100 50 50 mm (l w h). - sealed with quartz windows.iv. light source- he-ne laser (632.8 nm, 2 mw) or sodium lamp (589.3 nm). - beam collimation: 0.5 mrad divergence.v. optical system- adjustable slit (10 500 m). - collimating lens (f = 150 mm, 50 mm). - precision rotation stage for detector (0.01 resolution).vi. detection system- photodiode/pmt detector with linear response (400 800 nm). - traveling microscope (0.01 mm resolution) or ccd camera ( 5 mp).b.measurement specificationsi.wavelength ( )range: 0.1 2 mm, resolution: 0.001 mm, accuracy: 1%ii. velocity (v)range: 800 2000 m/s (liquids) resolution: 1 m/s accuracy: 2%iii. diffraction angles- measurement range: 30 resolution: 0.01 , experiment name: to verify the stefans law of radiation and to determine stefan s constanta.core componentsi.black body radiator- cavity-type design (emissivity 0.99). - material: nickel-plated copper.- operating range: 50 c 600 c. - aperture diameter: 10 mm 0.1 mm.ii. heating system- pid-controlled furnace (0 600 c). - stability: 0.5 c at 300 c. - power: 500 w (ac 230v).iii. temperature sensor- type k thermocouple or pt100 rtd. - accuracy: 0.5 c at 500 c (nist-traceable).iv. radiation detector- thermopile sensor (spectral range: 0.3 20 m). - responsivity: 10 v/w.- active area: 10 10 mm .v optical path. - water-cooled collimating tube with baffles.- adjustable aperture to define solid angleb.measurement specificationsi. temperature range100 c 500 c (reso

Central Government/Public Sector

CTN :40825503 Due date: 15 Jul, 202515 Jul, 2025 NA
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - manufacturing unit; installation of hydro-cyclone separator in hvlr unit of new ammonia storage tank area as per sow and quantum of job; service provider

State Government

CTN :40771915 Due date: 14 Jul, 202514 Jul, 2025 NA
Tender For supply of machine, equipment and others - list of machine and equipments, laproscopic hd camera brand - karl storz/conmed/olympustechnical specificationresolution: 1920x1200 pixes / 1900x1000 pixescable length: 300 cm, ultrasonic harmonic scalpelbrand - johnsontechnical specificationdimensions: (hxwxd) 5.3" 14.5"x15.2" voltage: 100-240 vac frequency: 50/60 hz rated current: 3 amp , ultrasonic harmonic scalpelbrand - valley labtechnical specification macrobipolar/bipolar: 473 khz sinusoid, 100% duty cycle. seal: 473 khz sinusoid pulsed , hand instruments for laproscopy brand- karl storz/ olympustechnical specification i) veress needle: it should be with spring action blunt style -12 cm: 1 no 10 cm: 1 no 8 cm: 1 no ii) trocar and cannula: 10 mm: 2 nos 7 mm: 1 no. 5 mm 6 nos it should consists of trocar, cannula with insufflation and multifunctional valve and must have pyramidal tip. iii) reducer/reduction sleeve 5 mm. 1 no iv) telescopes: 10 mm- 0 - 1 nos -30 - 1 nos 5 mm-30 1 nos rigid rod lens system provides good resolution and the better dept perception. it should have uniform image brightness and autoclavable. the 300 forward oblique angle and permits for greater latitude for viewing underlying areas under difficult anatomical conditions. v) suction cannula: 10 mm - 1 no 5 mm -1 nos vi) laparoscopic scissors: curved (monopolar metzenbaum dissector 5mm diameter): 1 nosstraight (bipolar): 1 nosperitoneal scissor: 1 nosvii) unipolar forceps (hook & spatula): 2 nos viii) bipolar forceps : 2 nos ix) atraumatic forceps: maryland dissector forceps: : 2 nos. fenestrated forceps: : 2 nos. x) needle holder (flat jaw) with handle : 2nos xi) monopolar cable (reusable):1 nos. xii) bipolar cable (reusable): 1 nosxiii) allis (double row of teeth) grasper: 1 nos xiv) aspiration needle: 1 nos. xv) reducer/ reduction sleeve (5mm): 1 nos xvi) grasping forceps (toothed & rachet 5mm): 2 nos xvii) laparoscopic knot pusher: 1 nos xviii) clip applicator (reusable): 5mm -: 1 nos : 10 mm: ino xix) uterine manipulator: 1 nos xx) clips( medium & large) xxi) drilling needle: 1 nosxxii) infiltration needle: 1 nos xxiii) biopsy forceps (toothed punch biopsy): 1 nos xxiv) myoma fixation screw: 2 nos xxv) tissue morcellator with base unit & accessories: 1 nos , dual wavelenght laserbrand- zeisstechnical specification laser type: diode, semiconductor wavelength : 1470nm+635nm max power: 15 watts/1470nm+5mv/635 aiming beam : 635nm/1, 4mw max or 515nm/2, 5mw max operation mode : continuous or modulated pulsed time : 0.05ms-1000ms beam delivery : sma905 connector optic fiber compatible : optic fibers having a core from 200um to 1000um, na=0.22~0.48 beam emission initiation : footswitch controller :microprocessor display : 10.1" ips with touch panel medical approved cooling : internal, air and thermoelectric cooling power supply of the laser: dc 24v/8.33a from the separate ac power supply of ac adapter : single phase 100-240va; 50-60hz, max 90w ac adapter dc 24v/8.33a medical approved laser dimensions: 27cm*24,5cm x 9cm laser weight: 2.75kg laser case dimensions : 53cm x 38cm x 23cm weight of laser with cases : 9kg environmental conditions during work : from +10 to 24 c degree, relative humidity from 30% up to 60% cass of medical device iib laser safety class 4 electric safety class i type b housing protection degree ip20b , hd camera setbrand- karl storz/ olympustechnical specification (i) hopkinsa forward-oblique telescope 30a, diameter 4 mm, length 30 cm, a utoclavable, fiber optic light transmission incorporated, color code ed : 1 nos(ii) telecam c3 : 1 nos(iii) image1 st hx one-chip full hd camera head, 50/60 hz, fixed focus, prog ressive scan, soakable, gas-and plasmasterilizable, focal length f = 16 mm, 2 freely programmable camera head buttons, for use with image1 x-link tc301, tele pack + and tp101 : 1 nos(iv) medical grade surgical monitor - fhd : 1nos(v) cold light fountain power led 175 scb, with integrated karl storz-scb, high-perfo

CTN :40768647 Due date: 11 Jul, 202511 Jul, 2025 NA
Tender For supply of components for ultrafast fiber laser system -2pin fiber pigtailed fbg stabilized laser diode with fc/apc connecter, compatible driver for 2 pin laser diode , tec controller for the 2pin laser diode , dual wavelength isolator , smps power supply, compatible for laser diode driver ,pm isolator , 1 x 2 polarization maintained coupler , 1 x 2 polarization maintained coupler, 2 x 2 polarization maintained coupler , pm patch cords with fc/apc connector
 Loading, Please wait...

Connect us via What's Up