Web Analytics Made Easy - StatCounter

Dam Structure Tenders

Get complete information related to latest Dam Structure Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Dam Structure Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Dam Structure Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45711072 Due date: 20 Jul, 202620 Jul, 2026 36.87 Lacs
Tender For special repair to dbs sub main wiring and miscellaneous items at mh and central institute at old amritsar cantt - taking down copper/ aluminium point wiring (light, fan, socket or power) complete including fixture and fitting such as switches, ceiling roses, pendants, regulators, sockets etc, removing materials to store for keeping in safe custody or for taking credit (creit for above items shall be made as per condtitions separately) and making good disturbed surface of walls, floors, etc complete all as specified and directed., material and labour for point wiring in existing conduit for following point controlled by one switch ( using red,black,green colour wires as colour codings) complete with 1.5 sqmm ( nominal cross section area ) single core frls pvc insulated unsheathed and multi stranded copper conductor cable 1100 volt ( isi marked ) drawn through and existing pvc concealed/conduit with all fittings and accessories including pressed steel powder coated sunken terminal box suitable for modular switch socket ( min 50mm deep and 1.6 mm thick sheet ,suitable size ) concealed in wall , including inner and outer plates ( cover plate ) suitable for fixing the modular switches/sockets/regulator etc including provn of 1.5 sqmm single core frls pvc insulated multi stranded copper conductor wire continues as earth wire connected to earth dolly etc including necessary cutting chases in wall and making good disturbed surfaces of walls/ceiling/floorsetc by using cement mortar (1:3) complete all as specified and as directed. note : 1 switch, socket, regulator, bell, ceiling rose, regulator, lamp holder will be measured and paid separately.a) for one light /fan/ buzzer point controlled by one 5 amp switch one way, b). for one three pin socket outlet 5 amps independent board., c) for one three pin 5 amps socket outlet on the same board with other switch, d) for one light point controlled by two way switch, all a per item no 2 here-in-above but with 2.5 sq mm size cable multi stranded frls copper wire unsheathed for one 3 pin socket outlet 15 amps on independent board including continuous earth wire of pvc insulated 2.5 sq mm copper multi stranded conductor connecting to common earth dolly complete all as specified and directed., material and labour for surface point wiring for one light point/fan point/bell point controlled by one switch ( using red,black,green colour wires as colour codings) complete with 1.5 sqmm ( nominal cross section area ) single core frls pvc insulated unsheathed and multi stranded copper conductor cable 1100 volt ( isi marked ) drawn and including surface pvc conduit with all fittings and accessories i.e. pipe bend,pipe hook, elbow,juction boxes etc including pressed steel powder coated sunken terminal box suitable for modular switch socket ( min 50mm deep and 1.6 mm thick sheet ,suitable size ) concealed in wall , including inner and outer plates ( cover plate ) suitable for fixing the modular switches/sockets/regulator etc including provn of 1.5 sqmm single core frls pvc insulated multi stranded copper conductor wire continues as earth wire connected to earth dolly etc including necessary cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc by using cement mortar (1:3) complete all as specified and as directed. note : 1. switche, socket, regulator, ceiling rose, bell, lamp holder will be measured and paid separatelya) for one light /fan/ buzzer point controlled by one 5 amp switch one way, b). for one three pin socket outlet 5 amps independent board, c) for one three pin 5 amps socket outlet on the same board with other switches, d) for one light point controlled by two way switch, all a per item no 7 here-in-above but with 2.5 sq mm size cable multi stranded frls copper wire unsheathed for one 3 pin socket outlet 15 amps on independent board including continuous earth wire of pvc insulated 2.5 sq mm copper solid conductor connecting to common earth dolly complete all as sp

Central Government/Public Sector

CTN :45740583 Due date: 20 Jul, 202620 Jul, 2026 1.66 Lacs
Tender For for the work of repair of head and cross regulator gate of madana distributary canal rd. 13.35 km. and m-3 r-1 minor rd. 4.20 km. of right bank canal of bargi diversion project.

Co-operative

CTN :45729955 Due date: 14 Jul, 202614 Jul, 2026 NA
Tender For 477/roof and damaged structure repair in clarification house

Central Government/Public Sector

CTN :45692696 Due date: 06 Jul, 202606 Jul, 2026 43.9 Thousand
Tender For 1) the damage structure of the all four side of the cabin straightening, rusted portion of structure cutting and new m.s sheet changing by welding 2) the structure of roof off the cabin rusted portion cutting new sheet changing by welding

CTN :45379784 Due date: 06 Jul, 202606 Jul, 2026 43.75 Lacs
Tender For corrigendum : repair and maintenance of kanjli cross regulator at r.d 207730 of west (holy) bein at kanjli wet land in distt kapurthala.

CTN :45437069 Due date: 27 Jun, 202627 Jun, 2026 NA
Tender For bid to ras supply of electrical items -good to match with existing surface complete all as specified and directed by eic , supply and fixing in repair modular metal flush box of 4 module with white cover plate including , supply and fixing in repair modular metal flush box of 6 module with white cover plate , material and labour for earthing complete with galvanized steel plate electrodes of size600x600x6mm thick , supply and fixing of led wall light bed side light fitting for study table including 3 watt led, aluminium body, , supply only inner container ss or as per sample suitable for vertical type geyser 50 itrs storage capacity , supply only inner container ss or as per sample suitable for vertical type geyser 25 itrs storage capacity , supply only in repair thermostat 0-75 degree as per exiting size as per oems specifications complete all as specified and directed , supply only in repair heating clement 1.5 kw, as per oems specifications all as specified and directed , supply only in repair heating element 2 kw, as per oems specifications all as specified and directed , supply only indicator lamp with flexibe copper wire of suitable size red by green , supply and fixing pvc connection with steel reinforced pipe for hot water connection of size 18 inches x 1 by 2 inches , supply only apperture plate ss suitable for 25 by 50 itrs geyser along with rubber gasket, nuts, bolts, etc , supply and fixing in repairs plug top 15 by 16 amps suitable for geyser socket outlet complete all as specified and as directed , supply and fixing in repair stop valve but fancy type, chromium plated, screwed down cp of size 15 mm fancy type complete all as specified and directed. , supply and fixing in repair bib taps, cast copper alloy with butterfly handle, screwed down, screwed for iron pipe , supply and fixing of solar collector plate panel as per existing size, specification and make of capacity upto 200 lpd , supply and fixing of solar water heater tank as per existing size, specification and make of capacity upto 300 lpd , supply and fixing of cimfr certified led fiame proof batten suitable for single t8 tube of 20 watt, ip 65 protected , supply and fixing cimfr certified led flame proof bay light, 60 watt, well glass in die cast al housing with heat resistant toughened glass, ip 65 protected. 240 volt, , supply and fixing of flame proof weather proof rotary switch with cable termination box in lm 6 aluminium allcy housing single pole 16 amp, 250 volts , supply and fixing of flame proof-weather proof switch socket and plug combined 16 a, 250 v 2p plus earth , supply and fixing of flame proof weather proof switch socket and plug combined 32 a, 500 v 4p plus earth , supply and fixing of flame proof weather proof metallic hose conduit 3 by 4 inches dia, m20 by 3 by 4 inches conduit mxm by fm x m by fx f 3 by 4 inches dia 300 mm long , supply and fixing of flame proof weather proof metallic hose conduit 3 by 4 inches dia, m20 by 3 by 4 inches conduit mxm by fmxmfxf 3 by 4 inches dia 500 mm long , taking down copper by aluminium point wiring light, fan, socket or power complete, including fixture and fittings , supply and fixing for concealed conduit for one light point wiring with 1.5 sqmm nominal cross-sectional area pvc insulated unsheathed single core copper cable working voltage 1100 volts grade , supply and fixing for concealed conduit for one light point wiring with 1.5 sqmm pvc single core cable for one ceiling fan by exhaust fan point controlled by one, one way switch and regulator , supply and fixing for concealed conduit for one light point wiring 1.5 sqmm pvc single core cable for one 3 point 5 amps switch socket outlet point controlled by one switch on the same board. , supply and fixing for concealed conduit for //bid details 3 / 81 one light point wiring with 1.5 sqmm pvc single core cable for one 3 pin 5 amps switch socket outlet point controlled by one switch on independent board. , supply and fixing for concealed conduit for

CTN :45656335 Due date: 07 Jul, 202607 Jul, 2026 96.20 Lacs
Tender For ¼1½ new hall and two rooms by demolishing the damaged room of primary school, chandpur. ¼2½ two new rooms by demolishing part of the damaged structure of the pre-built primary school civil line. ¼3½ ward&16 sanmilion u.p.v. diet complex roof waterproofing and toilet repair work. ¼4½ sanvilion u.p.v. construction of new rooms and a kitchen by demolishing the damaged room of harich udra nagar. construction of new rooms by demolishing the damaged room of pvt. police line.

CTN :45646479 Due date: 13 Jul, 202613 Jul, 2026 NA
Tender For dismantling of damaged structure and expanding of working area to provide incubation space at pilot plant, at icar-nmri, hyderabad

CTN :45414149 Due date: 23 Jun, 202623 Jun, 2026 5.65 Lacs
Tender For corrigendum : repair of gates and gearing system of cross regulator at rd 349612 of sirhind feeder. - estimate for repair of gates and gearing system of cross regulator at rd 349612 of sirhind feeder.

CTN :45628715 Due date: 27 Jun, 202627 Jun, 2026 12.50 Lacs
Tender For restoration of existing damaged structure (gs roofing) & internal and external finishing work i/c toilets at rsrw office at bamanwada, vileparle east mumbai-99 dg-2026-27.
 Loading, Please wait...

Connect us via What's Up