Web Analytics Made Easy - StatCounter

Data Acquisition Switch Tenders

Get complete information related to latest Data Acquisition Switch Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Data Acquisition Switch Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Data Acquisition Switch Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

corporations/Associations/Others

CTN :40126145 Due date: 05 May, 202505 May, 2025 2.62 Lacs
Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s

corporations/Associations/Others

CTN :40126147 Due date: 05 May, 202505 May, 2025 2.62 Lacs
Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s

CTN :39912918 Due date: 24 Apr, 202524 Apr, 2025 NA
Tender For spare parts, essential items for mahewa workshop - a, tool box (make - toporia , honey ton, deneers ), def transfer system digital voltage 220/50hz(ac)-turbine measuring principle-lcd display-maximum flow: 35lpm-suction hose: 1.5mtr-delivery hose: 4mtr-nozzle: automatic-inlet/outlet 1"-printer-yes-nozzle holder-yes, battery charger250ah,upto 12 batteries charging simultaneously, oil cooled. technical data input voltage: 220v power (kva): 1 charging voltage (v): 12/24/36/48/72/96simultaneously, battery charge: 1,2,3,4,6,8 & 12. weight: 50kg. l x b x h: 600 x 450 x 450mm, wheel chowk hcv (yellow ), wheel chowk hcv (orange), wheel chowk hcv (green), mechanical creeperhigh grade durable plastic model: kc0536" length - 36" wheel &size : 6 nos. & 3" n.w. (kg) : 4 g.w. (kg) : 5 package size (mm) : 930x420x100, safety goggles, safety shoes, pneumatic nut runners 1 (pistol type )bolt capacity: 48mm max. torque:2980nm free speed: 3800rpm mechanism: pin less hammer air inlet: 1/2" air pressure: 8-12 kg, anvil length: 8" net weight: 17.0kg., pneumatic nut runners bolt capacity: 39mm max. torque:3200nm free speed: 3800rpm mechanism: pin less hammer air inlet: 1/2" air pressure: 8-12 kg, anvil length: 8" net weight: 16.4kg., hydraulic jib crane (3 ton) capacity: 3 ton (overall height : 4500mm approx, overall width : 1050mm approx, height of upper : 650mm, length of horizontal arm: 2500mm weight: approx 350kg., air compressor 7.5hp *cylinder no.. 2, *motor required: 7.5hp 440v, 3 phase *rpm: 660, *pd cfm 26.25, *fad cfm 19.70, *max. psig 175, *pressure kg/cm2g 12.3, *air receiver 250ltr tank *weight of unit: 325kg * package size: 82" x 30" x 49", pneumatic greasing equipment bgrp/15, hydraulic trolley jack (15 ton) max. height: 560mm, min. height: 155mm, length: 1651mm, breadth: 215mm, weight: 150kg., double piston hydraulic trolley jack (04 ton)max. height: 510mm min. height: 75mm weight: 32 kg, 17 drain pan 16 ltr, rotary barrel pump pump inlet : 1" outlet : 3/4" use on 50-210 litre drums, measuring cans 0.5 ltr (measuring cans in plastic ), measuring cans 1 ltr(measuring cans in plastic ), measuring cans2 ltr(measuring cans in plastic ), measuring cans3 ltr(measuring cans in plastic ), measuring cans5 ltr(measuring cans in plastic ), digital multimeter, filler gauge, trip type torque wrenches :0.3 - 1.4 kgf (3/8 ), trip type torque wrenches :0.5-3.5 kgf (3/8 ), trip type torque wrenches :5 23 kgf (1/2 ), trip type torque wrenches :7 35 kgf (1/2 ), trip type torque wrenches :14 56 kgf (3/4 ), trip type torque wrenches :49- 105 kgf (3/4 ), dress for worker (dangari)

CTN :39616933 Due date: 13 May, 202513 May, 2025 NA
Tender For procurement of spares for il-76/78 aircraft - screw, washer bolt head, kp3 cable connecter ant assemb, bracket, member bent, member bent track no. 1 rh, member bent track no. 1 rh, member bent track no. 3 lh, member bent track no. 4 rh, member bent track no. 4 lh, member bent track no. 5 rh, member bent track no. 5 lh, door access track number 3 rh, door access track number 3 lh, door access track number 4 rh, door access track number 4 lh, flight data transfer unit, 12d relay unit, surge suppressor assembly, relay box - 032 air conditioning, valve fuel (v), lamp
 Loading, Please wait...

Connect us via What's Up