Tender For bid to ras corrigendum : supply of degn sup inst test comm of water management system d d -pump set-minimum head 30 mtrs , power db with suitable for 1 working 1 stand by pumps , power db with suitable for 1 working 2 stand by pumps , plc hmi control panel with smps 1 working 1 stand by pumps , plc hmi control panel with smps 1 working 2 stand by pumps , inline electromagnetic flowmeter , smart pressure transmitter range 0-16 bar , pressure switch range 0-10 bar , pump set-minimum head- 15 mtrs , vertical pump set-minimum head- 15 mtrs , power db with suitable for 2 working 3 stand by pumps , plc hmi control panel with smps - 1 working 1 stand by pumps , plc hmi control panel with smps - 3 working 2 stand by pumps , pressure switch, range 0-10 bar , 1 pump set-minimum head- 10 mtrs , plc hmi control panel with smps for 1 working 1 stand by pumps , plc hmi control panel with smps for 1 working 2 stand by pumps , smart pressure transmitter range 0-16 , pump setminimum head- 22 mtrs , plc hmi control panel with smps for 1 working1 stand by pumps , ultrasonic hydrostatic level transmitter , magnetic float type level sensor , motorized valve with on off control 40nb , motorized valve with on off control 50nb , motorized valve with on off control 65nb , motorized valve with on off control 80nb , armoured cable 1. 1kv grade 3 core x 2. 5 sq. mm , armoured cable 1. 1kv grade 3 core x 4 sq. mm , armoured cable 1. 1kv grade 3 core x 6 sq. mm , cable tray , plc remote control panel with smps and suitable qty of relay boards , control panel with master plc ups , fiber optic cable 4 pair pvc , signal converter rs485 to fiber optic , signal converter ti port to fiber optic converter , cat 6 cable with pvc conduit , industrial grade 8 port lan switch , control room server with scada software 2000 tags licensed copy , plc programming software licensed copy with laptop , installation testing and commissioning of complete system ) /bid number: gem/2026/b/7268901 * /dated: 05-03-2026 & & / bid document1 / 42
Tender For supply and installation of telecom and scada equipments for extending data connectivity to upcoming cgd hookups and lmc connectivity in southern region on annual rate contract basis - supply items under arc for telecom system, supply of mpls tp equipment, supply of ip/mpls type switch, supply of converter, ac-dc (230 v ac to 48 v dc), ac-dc (230 v ac to 24 v dc), dc-dc (48 v dc to 24 v dc), dc-dc (24 v dc to 48 v dc), supply of battery charger with battery backup, supply of porta cabin, supply of lct, supply of equipment racks, supply of solar panel with battery back up 300 w, supply of solar panel with battery back up 200 w, supply of solar panel with battery back up 50 w, supply of explosion proof telephone, supply of weatherproof telephone, supply of acoustic half hood booth, supply of multi-paired armoured cable (10 pair), supply of 6 twisted pair, 1.5 sq. mm ( 12 core ), individual pair andoverall aluminium mylar tape shielded with drain wire, supply of 6 twisted pair, 0.50 sq. mm ( 12 core ) individual pair and overall aluminium mylar tape shielded with drain wire, supply of telemetry interface cabinet (tic), supply of analog phones, supply of fxo gateway, supply of fxs gateway, supply of ethernet switch, supply of rtu, supply of mini rtu, supply of ftc, supply of joint closures, supply of ip camera, supply of spares for telecom, supply of spares for rtu, supply of ethernet to serial converter, supply of optical to serial convereter, supply of rs 232 to rs 422/rs485 converter, supply of optical to ethernet converter, supply of out door equipment panel, supply of field mounted enclosure conforming ip-66, supply of gprs modem, supply of atex switch 8 port, supply of 24f ofc cable, supply of rtu management licenses for makes like husky, schneider, etc, telecom system (works), installation of mpls/tp equipment, integration of mpls/tp equipment with existing nms, installation and commissioning of solar system, installation of porta cabin, laying and termination of multi-paired armoured cable (10 pair), installation and configuration of converter/switch and interfacing of same with flow computer and integration with scada system, installation of tic panel, design, engineering and submission of documents, testing of ofc and submission of reports, earthing works, installation testing & commissioning of instrumentation cable, installation commissioning and integration of rtus in existing scada server, installation commissioning and integration of mini rtus in existing scada server, installation and integration of ip cameras in existing server for each cameras, installation of gprs modems if supplied as free issue, extending of leased lines for 1000 km distance including modems (one ethernet interface & one e1 interface for lan) at both ends, rectification of ofc including supply of joint pit with identification of fault and testing of of cable, installation of outdoor panel, transportation charges for free issue material (per km rate to be quoted), laying of ofc through hdd method, laying of ofc through direct trench method, point to point radio communication (2.4/5.8 ghz licence free ism band), laying of ofc cable ( if ofc supplied as free issue by gail), blowing of ofc in duct, manday charges [post-installation manday charges for rtu/telecom works on an on-call basis, including troubleshooting, system calibration, software updates, configuration adjustments, and performance optimization. ], total amount excluding gst, gst (cgst&sgst/utgst or igst) in percentage (%) on net total amount
Tender For revamping and upgradation of existing scada system including associated software with necessary accessories training as per specifications in volumetric laboratory hmci division cwprs pune 24
Tender For (sh -sitc of automation and management system with microprocessor-based control panel, online monitoring and wireless connectivity with scada software at gk-1
Tender For supply of spares for high temperature high vacuum heat treatment furnace d d - lanthanum doped molybdenum double grooved heating element size 570 l x 60 w x 0 point 5 thk part no f 18194 hz 01 08 01 , molybdenum fasteners for heater fixing m6x30mm part no f 18194 hz 01 08 01 a , front radiation shield assembly dia 830 x point 05 thk x 6 layers 3 layers of moly and 3 layers of ss part no f 18194 hz 02 01 00 f , rear radiation shield assembly dia 830 x point 05 thk x 6 layers 3 layers of moly and 3 layers of ss part no f 18194 hz 02 01 00 r , lanthanum doped molybdenum heating element holder part no f 18194 hz 01 10 00 , molybdenum base plate size 480 mm x 950 mm x 6 mm part no f 18194 hz 03 00 01 , molybdenum platform assembly including fasteners size 550 mm x 950 mm part no f 18194 hz 03 00 00 , high alumina insulators part no f 18194 hz 01 09 06 , industrial pc with plc scada and necessary software part no f 18194 cs plc ss , heater for 20 inches diffusion pump part no f 18194 vs dp sh
Tender For corrigendum : supply of software license keys of ge make scada (kyb9) not supplied by the previous contractor m/s ike electric pvt. ltd. and integration of 33kv gis, bcus (abb make) with ge make sas at 220kv gis s/stn. roj-ka-meo. (against risk purchase). - supply of software license keys of ge make scada (kyb9) not supplied by the previous contractor m/s ike electric pvt. ltd. and integration of 33kv gis, bcus (abb make) with ge make sas at 220kv gis s/stn. roj-ka-meo. (against risk purchase) (detailed activity as per boq provided in the tender document)
Tender For auction sale of others - scrap miscellaneous item(1)main & stand by computer each processor consisting of pentium iii based on latest 600 mhz 32 bit 128 mb ram, 20gb hdd 52 cd drive (writable) 1.44 mb fdd, 104ms window compatible key board & mouse, 15" colour svga monitor with network card & tcp/ip protocol,2nos(2)communication server pentium ii based pc or latest 600 mhz 32bit 128 mb ram, 20 gb hdd, 52xcd drive (writable) 1.44mb fdd,104 ms window compatible key board & mouse, 15" colour svga monitor with network card & pcp/ip protocol.,2nos(3) man & stand by work station each consisting of pentium iii based pc or latest with minimum 128mb,ram 20 gb hdd, 52xcd drive 1.44 mb fdd & speed 600 mhz along 3nos. 19" svga fully graphic colour vdus with each machine will have it separate alphanumeric key board & mouse b67 network card & tcp/ip support multimedia kit should be available to give distinguishing alarm to tpc with network card & pcp/ip protocol,5nos(4) laser coloured data logging printer suitable for printing a3 size paper (with minimum 600x3000 dpi resolution),2nos(5)indication switching pannel to display ups alarm/status,1no(6)master clock & slove clock,3nos(7)front end driver (display),3nos(8)2x5 kva dual load sharing ups system,1no(9)server computer & fep computer,4nos(10)work station computer,4nos(11)ac modem,4nos(12)dot matrix printer,2nos(13)scada software for dual hot stand by stand by system(cd)(1-13)location-sse/rc/ddu,note-pc-17nos.,dot matrix printer-02nos,colour printer-02nos,electronic device-06nos,cloc-03nos,cd-01no,total weight of electronics items-473kg,ups-1 set, total wt-375kg(ferrous-353kg,non-ferrous-22kg)
Tender For selection of a consortium partner for participation in the bid for design, engineering, manufacture, assembly, inspection, testing at manufacturer works before dispatch, packing, supply, delivery at site, including insurance during transit, subsequent storage, erection and commissioning of underground cabling network (mv and lt), smart grid applications including supervisory control and dataacquisition (scada), advanced distribution management system (adms), outage management system (oms), gis mapping and integration, optical fiber cable communication system by laying of optical fiber cable (ofc), third party it application software (such as billing, erp, and cis) integration along with underground power cable and distribution control center (mcc and bcc) with distribution network automation (dna) in agartala municipality area, tripura (package a) of agartala smart grid.