Tender For providing of custom bid for services - preparation of gad duly taking details from field such as measurements, level details etc and preparation of detailed drawings in auto cad,custom bid for services - preparation of detailed estimate based on gad and any other data required to be collected from site in excel format,custom bid for services - preparation of completion drawing in autocad duly obtaining actual measurements of work executed and getting scrutinized and certified by site officials or engineer in charge,custom bid for services - preparation of conceptual sketches for new proposal,custom bid for services - preparation of abstract estimate for new proposals
Tender For providing services of computer operator autocad in the office of senior architect ii, cpwd, mumbai and 1 no office boy helper cum dak boy in the office of executive engineer-i, pune, cpwd, mukundnagar, pune for the period of aug-2025 to jan-2026.
Tender For contingencies of various works under ee, jaipur-ii ( sub division-iii works), cpwd jaipur ( sh:- providing services of autocad operator in the architect wing o/o chief engineer jaipur cpwd, nirman bhawan sectior -10 vidyadhar nagar jaipur)subwork/packages:contingencies of various work under ee, jaipur-ii( sub division-iii works) cpwd jaipur.( sh:- providing services of autocad operator in the architect wing o/o chief engineer jaipur cpwd nirman bhawan sector-10, vidyadhar nagar jaipur.)
Tender For a/r & m/o safdarjung hospital, new delhi (sh: providing services of autocad operator in the office of senior architect (rd-ii), east block-i, r. k. puram, new delhi
Tender For corrigendum : purchase of sports exercise physiology lap equipments - cardiopulmonary exercise testing systemsystem should be compact can be used in laboratory operation and low maintenance costs and easy servicing. system should be state of the art computerized telemetry breath test analyzer for on-line breath by breath measurement of exercise test of respiratory system to measure following parameter: time, ve, bf(rr), hr, feo2, feco2, peo2, peco2, vo2, vco2, ve/vco2(eqco2), ve/vo2(eqo2), rq(rer), vd/vt, vo2/kg, vo2/kg/hr, met, watt(work), hr, ttot, ti, te, ti/te, ti/ttot, pef, pif, br, vet, sum, tv/te, o2 kinetics, oxygen deficit, oxygen debt parameters and indirect calorimetric. wireless hr recording system, indirect cardiac output by wassermann algorithm system should comply ats and ers guide line and it should be ce certified., iso certified system should have automatic ambient conditions measuring system. system should work under temperature range 0 to 50 celsius. system should have facility for automatic calibration of analyzers. volume transducer calibration with precision calibration syringe. system should meet following technical specification flow rate measurement: measuring headpiece should be either through turbine /dvt/ pneumotach and dead space less then 40 ml, it should not be affected by humidity , flow range +/- 18 l/s and accuracy 2% oxygen analyser : should be either electrochemicalcell/paramagnetic and measurement range 0- 100 %,response time t90 100 ms and accuracy +/-0,04 % and- resolution 0,02 %carbon dioxide analyser : should be ndir (infraredabsorption) and measurement range 0 - 10 %,-response time t90 90 ms , accuracy +/- 0,04 %, andresolution 0,02 % software should support latest windows or latest andin corporate customized predicted normal equations.software should be capable of changing graphics displays during real time testing. system should have facility for automatic treadmill or bicycle ergo meter control. should be supplied with software, standard accessories for operation manual carrying case for field use. system should be supplied with latest dataacquisitionsystem, deskjet printer and ups. system should comply en iso 13485:2003, en iso 9001:2000, ec certificate93/42/eec, programmable treadmill running machine with user terminal (display &keyboard) stand- alone and remote control via rs232 running surface: l:170 cm (minimum), w: 65 cm (minimum) maximum possible load: 200 kg (440 lbs) speed range: 0-40 km/h elevation: 25% (14 maximum elevation) motorized adjustment, reverse belt rotation. motor system 3.3 kw, single phase ac motor, maintenance free and brushless power transmission: frequency inverter, poly v- belt, very quiet operation safety system: emergency-off safety stop switch (safety lanyard with actuator, pull cord and clip); potential equalization bolt; transformer for potential-isolation from the mains ambient condition: temperature: +10to +40 degrees c, humidity 30 to 70% display (resolution): lcd display heartrate monitoring: wireless transmitter; the treadmill should be able to interface with well-known compatible metabolic gas analyzer as per standard and custom exercise protocols different programs safety harness-1. indispensable accessory for stress testing, accident prevention and for the general safety of athletes.2. safety arch with different heights and widths to fit all running machines.3. an emergency stop at the crossbar of the safety arch allows automatic stop of the running belt in the moment a fall occurs.4. the harness and chest belt (available in 5 sizes: xxs, s, m, l, xl) secure the subject and prevents falling over to the front.5. chest belt straps do not pinch or restrict the athlete", programmable ergometer functional design and excellent stability, load up to 160kg. easy to use saddle, handle bar and pedals speed independent and dependent power control handle bars are easy to change to suit different tests, rotatable by 360 degrees. mechanical/motor-a