Tender For supply of conference system - controller (hybrid) , conference system - chairman unit (wired) , conference system - delegate unit (wired) , 200w amplifier , interactive panel 86 inch with ops , vc camera elite 4k premium 20x , pro audio digital signal processor (12 channel) w/o mic , passive 5" wall mount speaker pair , vc server (main & standby) , multi functional device , control unit , installation and commissioning
Tender For name of purchase: pc computer with full set make : hp/dell/lenovo - pc computer with full set make: hp /dell / lenovoprocessor :12th generation intel core i3- 12100 processor (p-cores up to 4.30 ghz) operating system : windows 11 home 64 (english) memory: 8 gb udimm ddr4 3200mha, hard drive:1tb sata hdd m.22280 ssd pcie gen3/4 connectvity: wifi 6e*, wifi 6 and wifi 5, bluetooth 5.2 ports: rear ports: 2xusb 2.0, 2xusb 3.2 gen 1, 1xvga, hdmi 1.4, ethernet (rj-45) front ports: 2xusb 3.2 gen 1, 1xusb-c 3.2 gen 1 1xcard reader, headphone / microphone combo jack (3.5mm), lxmicrophone (3.5mm) 24"display,mouse, keyboard and and web camera graphics: integrated intel uhd graphics 730intel uhd graphics 730.
Tender For supply of multi process control trainer setup for instrumentation engineering lab under mhrd scheme - purchase of multiprocess control trainer setup for instrumentation engineering lab under mhrd scheme - multiprocess control trainer set up, multiprocess control trainer set up - specifications:- setup must contain flow, pressure, level, temperature loops also derived loops like cascade and feedforward loops. temperature loop must be independent. setups consist of a circulating closed loop water plant or circulating water system including control valve, tanks, independent pumps and necessary valves including bypass valves and rotameters. using this we can be able to do flow control loop with pid,level control loop with pid,and pressure control pid, as independent experiments.the setup must include the following:1.one linear characteristics diaphragm operated control valve with 15mm stroke 1/2-inch size, type: high-capacity globe seat leakage class (as per ansi/fci 70.2).2.measuring tank with volumetric measurement scale and 1000mm level, in of 25 ltr capacity. sump tank min of 40 ltr capacity. all tanks made of ss304, with sight glass, and finished with mat steel finish.3.2 no s smart dp transmitter for flow and level measurement with hart protocol, display and keys integrated for calibration,0-1000mmh2o measurement range,0.01% accuracy, international iso certified ce approved make,24v supply,4-20ma output, loop powered.4,1nos of magnetic flowmeter with display and keys integrated for calibration,0-2000lph measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, international iso certified ce approved make,24v supply,4-20ma output to measure flow as a independent loop.5,. smart pressure transmitter and temperature transmitters with hart protocol, display and keys integrated for calibration, pressure transmitter 0-10bar measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, temperature transmitter 0-250 rtd type international iso certified ce approved make,24v supply,4-20ma output, loop powered.6, pressure tank of 24 liters with necessary valves for pressure loop.7.1nos orifice plate (ss304) and assembly grade with flange 1/2-inch size for flow measurement.8.2 nos pumps 0.5hp, ss centrifugal pump, minimum 1-inch pipeline of ss or high-pressure withstanding plastic with plastic welding.9. rotameters 2nos 1 inch size flow: 200-2000 l/h,ss thread, clear acrylic type.10, plc control station with 4 analogue inputs and one analogue output with necessary digital inputs and outputs to operate all loops directly from panel side.plc must have ethernet connectivity with supported protocols profinet and modbus tcpip.11.required all pneumatic components to full fill the process loops such as fr,needle valves etc.12,i to p converter 4-20ma to 3-15psi with 1/4" process connection with proper copper copper tubing.13, loop including flow pid control, level pid control, pressure pid control, cascade control (level flow), ratio control (flow flow).14.all loops can be operated using a scada system and independent pushbutton control includes trend of all analogue signals and pid tuning. scada direct profinet connectivity to plc and computer with intel i5 processor, 8gb ddr3 ram,1tb sata hdd,licenced windows 11 professional.15, required a standalone software application that must be installed on pc in which it can used to control and monitor all the functions used in scada. the application must contain process parameter trend graph plot for to study about process loops.16.the whole system setup must be in ms powder coated standalone mobile table with lockable castor wheels. all the components used be industrial. copper tubing for air connection, pressure gauges 4inches 3nos, electrical wiring connection to be flexible for to connect field devices. panel with switches, indicator, test points with banana connectors as required, multistrand wire with proper insulated lugs, ferruling & neat wire dressing & clam
Tender For bid to ras supply of table mic , roviding control expansion with 8 logic inputs , speakers , amplifier , active led , 55 inch 4 k digital display , 32 inch touch full hd display , network video endpoint for q sys ecosystem , poe toch screen controller , switch and control systemport network switch preconfigured for qsys audio video , ptz camera systemvideo conference camera system , digital podium , cable and connectors , installation and commissioning table mic polarity/ positive sound pressure on diaphragm produces positive voltage on pin 2 relative to pin 3 of output xlr connector/ type - electret condenser/ frequency response 50 17000 hz output impedance - 180 / output configuration - active balanced/ sensitivity - @ 1 khz, open circuit voltage/ cardioid 30 dbv/pa/ super cardioid 28 dbv/pa/ omnidirectional 22 dbv/ pa/ maximum spl - 1 khz at 1% thd, 1 k load/ cardioid 119 db/ super cardioid 118 db/ omnidirectional/ self noise - a weighted/ cardioid - 23 db spl/ super cardioid - 21 db spl/ omnidirectional - 15 db spl logic connections: led in active low ( 1. 0v), ttl compatible. absolute maximum voltage: 0. 7v to 50v. logicout - active low ( 0. 5v), sinks up to 20ma, ttl compatible. absolute maximum voltage: 0. 7v to 24v (up to 50v/ through 3k ). make: bose/ ahuja or similar brand, digital processor (dsp) - unified core with 24 local audio i/o channels, 128x128 total network i/o channels with 8x8 software-based dante license included, usb av bridging, dual lan ports, pots and voip telephony, 16x16 gpio, 16 next-generation aec processors, 1ru/ q-sys core 110 scripting engine software license, perpetual. , q-sys peripheral providing 4 mic/ line inputs. up to 4 devices daisy-chainable. 1u-1/4w, powered over ethernet or + 24 vdc. surface mountable, rack kit sold separately/ q-sys ) /bid number: gem/2026/b/7101502 * /dated: 22-01-2026 & & / bid document1 / 23
Tender For supply and installation or urs at various areas of zone south, jodhpur - providing & laying xlpe insulated & p.v.c. sheathed armoured aluminium cable confirming to is :7098 p - i of 1.1 kv with h4- grade electrolytic aluminium conductor confirming to is 8130 of purity >99.6 %, round / flat strip armouring of cables, inner / outer sheath confirming to is:5831 in existing rcc / hume / stoneware / pvc pipe/ open duct/cable trench / cable tray(with cable tie) including testing commissioning etc. as required of following size.10.0 sq. mm x 4 core, supply & installation of unified regulation system (urs) for existing street light that meets the following specification.the system must feature a 240mhz dual core processor with gsm/gprs communication capabilities and support for ota firmware updates.it should come with an internal class 1.0 energy metering system that can provide real time data of crucial electric load parameters along with fault and theft alerts.the urs must include remote load scheduling and control functionalities with a feedback time of less than seconds.the enclosure confirms to ip55 standards,and be fire retardant,weatherproof,and rustproof. the system should use a lightweight protocol for secure ,real-time communication and include cloud based software for comprehensive device management and remote control. it should be able to control single phase 5.5kw and 3 phase street light load upto 8.5kw and should come with 2pole/4pole mcb upto 25a/40a at output for short circuit protection .having a 2-year warranty urs will be installed at site as per direction of engineering incharge. (size 570*520*190mm)
Tender For supply of interactive panel , minimum 55 professional display smart tv , presenter tracking camera , student camera 4k ptz camera with 20x optical zoom , wireless microphone system hand held 01 lapel collar-01 , wireless microphone system 2 handheld , 12 channel digital signal processor dsp , amplifier , 2 way wall mount passive speakers , i7 12th gen 16gb ram 512gb ssd win 11 with wireless keyboard mouse , digital podium with built in display front signage screen 2 gooseneck mics , video mixer and switcher , cabling hdmi usb lan etc , ceiling mount kit for camera , wall mount kit for camera , any other items with installation testing commissioning