Get complete information related to latest Data Recording Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Data Recording Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Data Recording Tenders.
Tender For supply of items - breast screening device with 500 scans/tests, cervical cancer screening device, breast cum cervical examination table, stand with touch panel tablet., breast & cervical examination (operator) chair, digital back end dashboard for recording and data management of reports (software), desktop (computer) with printing facility, latest version & configuration with factory preloaded windows, breast exam screening test cartridge, cervical examination kit
Tender For providing architectural and technical consultancy for planning, designing, engineering and preparation of detailed project report including feasibility study for setting up of tier-iii disaster recovery data center along with allied structures including design of green rated building with building services, water tank, site development, stp/etp etc., and non-civil works such as driver face in auto number plate recording system, baggage scanners, door frame metal detectors, boom barrier, emergency light and signages and it includes design of electrical systems such as ups system, intelligent pdu, air-conditioning system, power supply systems including internal electrical installations and electrical sub-station. it covers the design of cctv surveillance system access control system, rodent repellent system, water leakage system, fire suppression system etc. it includes design of network systems such as infrastructure of internet gateway, fois net and utn, data center lan network security, adc, slb and waf, internet bandwidth triplication links and drwan, campus lan and network operations. it includes development of data center infrastructure management software and obtaining uptime tier-iii, tia rated-3 data center design certification. the rate includes complete design with design basis report and dpr.
Tender For supply, erection, installation & commissioning of electromagnetic bulk flow meter and installation, commissioning of plc/scada system for the monitoring and recording of outlet flow data, monitoring. programming of plc & scada system. integration of ocems for continuous monitoring of effluent parameters of the stp for local monitoring and analysis, anomaly detection and reporting. design, supply, installation and commissioning of 16 kw advanced on-grid solar pv system at stp in ilkal cmc
Tender For corrigendum : technical specification point wise dbs implant & accessories - dbs rechargeable with directional lead with25yr battery life & image guided programming integrated inside clinician programmer with micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers, usfda & ce approved kit contents: rechargeable pulse generator-1 , directional lead kit -2 , extension kit -2 , burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1, patient charging kit -1 , dbs rechargeable with non directional lead with 25yr battery life & image guided programming integrated inside clinician programmer micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers. have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage, usfda & ce approved kit contents:rechargeable pulse generator -1, non-directional lead kit -2, extension kit -2, burr hole locking kit -2, tunneling tool -1, patient remote control kit -1, patient charging kit -1, dbs non rechargeable with directional lead with image guided programming integrated inside clinician programmer micc multiple independent current control technology &bluetooth connectivity with clinician and patient programmers,usfda & ce approved kit contents: non-rechargeable pulse generator -1 , directional lead kit -2 , extension kit -2, burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1,), dbs non rechargeable with non-directional lead with image guided programming integrated inside clinician programmermicc multiple independent current control technology withbluetooth connectivity with clinician and patient programmers. should have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage,usfda & ce approved kit contents: non-rechargeable pulse generator -1, non-directional lead 1), dbs implant kit with non-rechargeable, 3t mri compatible and sensing enabled ipg and directional leads.the implanted pulse generator (dbs neurostimulator- ipg) should have a minimum service life of 5-7 years and there should not be a need to recharge it periodically.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the leads should be able to stimulate in specific directions, in addition to the ability to stimulate circumferentially. markers on leads should facilitate directional programming even if lead rotates. the leads should also be able to sense lfps.burrhole kit should be there for securing lead in place. microelectrodes for intra op stimulation and recording should be there.the extension connecting the lead and ipg should be flexiblethere should be a tunneller to place the extension wire and the tunneller should be metallic and firm to enable smooth tunnelling.the system should have approval for conditional full-body 1.5t & 3t mri compatibility.patient programmer, enabling the patient to see and if needed, modify the stimulation under guidance, should be available. patients should be able to mark dyskinesia, tremor etc. using the programmer., dbs implant kit with rechargeable, 1.5t & 3t mri compatible and sensing enabled ipg and directional leads.the implantable pulse generator (dbs neurostimulator- ipg) should have a service life of 15+ years if regularly recharged by the patient at specified intervals.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the system shou
Tender For supply and installation of 02 channel voice datarecording and processing unit (vdrpu) as per rdso /spn / tc / 38 - 2002 ver 2 or latest [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : 1.supply and installation of 02 channel voice datarecording and processing unit (vdrpu) as per rdso /spn / tc / 38 - 2002 ver 2 or latest2.supply and installation of vhf receiver to record communication with in the radio coveragearea of station vhf equipment. note: vhf based secured communication equipment has in-built vhf radio which is configured on dg (driver guard) frequency to record communication. if railways also wants to record communication on shy frequency simultaneously, then this is required per location.3.supply of server hardware and software for centralized monitoring of voice communicationwith voice logging for entire stations in nagpur division through vhf based secured communication equipment as per no rdso / spn / tc / 38 - 2002 ver 2 or latest amendments or latest. the technical specification is as follows: - (i). processor - intel core tm i7-6700t, memory: 16gb, hard drive: 1 tb ssd, graphics card:nvidia geforce gt 730 (4 gb ddr3 dedicated), networking 802 m, 11 b/g/n (1x1) and bluetooth 4.0 m. 2 combo, sound card: dts studio sound?, keyboard, and mouse: hp usb wired keyboard with volume control, power supply: 180w ac power adapter, audio: dts sound?, memory slots: 2 dimm , external i/o ports: 2 usb 3.0; 4 usb 2.0 dimm, windows 11 operating system, led monitor: 24 (23.08 ")note: the server should be integrated with vdrpu and receiver (item 1&2) for all station of nagpur division
Tender For supply, installation and commissioning of an additional hardware (controller cum memory unit) with usb port and necessary software for integration of usb and recording memory in micas vcu and cdac based tcn vcu locos fitted with annual rate contract make driver display unit (arc/ddu/v2.0, annual rate contract/ddu/v2.1 & annual rate contract/ddu/ v2.2) for recording of 43 nos of critical datarecording parameters of 3-phase locomotives at a sampling rate of 1 second as per clw/crj letter no. cd& d/t/39, vol-i dt:-06.12.2023 & rdso mom issued vide lr. no: el/ 3.1.35/17 dtd.28/04/23. [ warranty period: 30 months after the date of delivery ]