Get complete information related to latest Dc Contactor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Dc Contactor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Dc Contactor Tenders.
Tender For material supply for the installation of 4 line hanging solar power fence at rajapuram estate - hanging solar power fence, p.p reel insulator , must be of virgin plastic metirial. polypropylene or equivalent with break down voltage of 15 kv(weight 25gm avg, length 4.6 cm avg), strain insulator, must of poly polypropylene plastic rated for 15 kv uv stabillized ,(weight 40 gm avg, length 7 cm avg), gi post 12 feet , 2" gi pipe, 14 guage thickness,total 14.5 ft length modified to 12 feet length and cut and welding to 90 degree bend 2.5 feet length at top end and having diametrically opposite holes of size 6 mm at end of bend pipe, intermediate post (t angle post) , 6ft., painted(25mm*25mm*3mm)having holes of size 6 mm at required interval of fencing installation, supporting post, 10ft.,gi-1,14 guage thickness,painted, stay (t angle), 2ft., painted(25mm*25mm*3mm), 12 swg ht wire, 12 guage,2.5 mm dia high tensile wire with zinc coating for use as conducting wires,binding strain insulator, 14 swg binding wire , high quality zinc coating wire for binding reel insulator, tighing support post with corner post, 1.5 mm stainless steel wire rop 304 grade, aluminium ferruel, aluminium ferruel 3 mm, wire tightner , permanat wire tightner made of special aluminium alloy designed for kv, uv stabillized, earth rod, copper plated earth rod 14 mm -3ft. length, earthing compound, earthing compound 8 kg, gate handle, gate handle and spring assembly, handle made of polyethylene, leadout cable,leadout cable for fence system double insulated gi cable inner core wire 2 sq.mm.hot dipped galvanised steel core, capaie of with standing 15kv should be provided to prevent bimetal salt formation at connections, single core 2.5 mm sq. cable, 2.5 mm2 single core copper cable for connecting the solar panel to the tubular battery through charge control unit with required terminal sockets,nut and bolt,washer, lightning diverter, 15kv -50kv rod gap arrester,must be capable of diverting stray lightning and adjustable for spark gaps adequate earthing to be provided, 100 watt solar panel, 100 watt/12 volt and above poly cristalline with 10 year warranty having iec/mnre certification, charge control unit, 20 a,12/24 pwm charge controller unit of standard make suitable to control the charging of the tubular battery, energizer, energizer with 10 kv output safety standards to be followed are bis 302-2-76 iec60335-2-76. switch-high, medium and low power setting., fence alarm system, fence alarm system covering area of 1.5 km, solar panel sapporting stand with metal box painted (for battery and energiser), 18 guage thickness metal box(lockable). gi-sheet, painted should be capable of housing battery, charge controller and energizer and fixed with reguired clamps and nut and bolt on solar panel suppoert stand made of gi pipe of 50mm diamere and b class type with suitable arreangement for holding the panel, warning sign, polyethylene plastic with satuatory wrning with signs, tubular battery 12v , 100ah, 12 v, 100 ah c10 rating with full 5 year replacement warranty (tower battery) for energising the energiser
Tender For corrigendum : set of auxiliary contactor for wag-9 loco. set consisting of 03 items in 3 nos-- (1) auxiliary contact for panto, 9 amps, 3 pole, dccontactor,110v dc, type-lcid 09 fd, qty.= 01 no. to clws spec.no.-clw/es/3/0040 (alt.-c). (2) aux. contactor for mr blower with 110v dc, 4 pole, 25 amp, type lcid 128 fd, qty.= 01 no. to clws spec. no.- clw/es/3/0012 (alt.-h) . (3) aux. contactor for power supply with 110 v dc, 4 pole, 25 amp, type- lcid 128 fd, qty.= 01 no. to clws spec. no.- clw/es/3/0012 (alt.-h) . [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variationpermitted: max 8 lacs ] ]
Tender For repairing of tower, replacement of damaged tension disc insulator and minor repairing of conductor of 132kv dhaligaon-barpeta lilo transmission line
Tender For auction sale of depot non ferrous scrap - lot no.p.nfc-1.bin no- 7.exmp.06.2026-27.08 description- scrap copper lump & sheets (comprising of fire bronze pieces, plats, stays, rivets, stude, rods, pipe etc) copper wire without insulation. copper boring & turning. our offer:- scrap copper miscellaneousllaneous with or without iron attachment. such as- rt dropper clip, catenery clip,contact tips for cgr (only copper), contact liver for cgr, bus bar, copper boring, plier, flexible shunt and mobile contact, scrap copper pipe,transformer oil cooler tube, rectifier bus bar , loop copper pipe, loader unloader pipe for a/c, half round oval contact copper, finger contact, stud bolt, copper ferule, carbon brush copper pigtail, copper tube, blow out coil for line contactor, r b shunt, shunt for armeter, blow out coil for shunting contactor, battery isolation switch, copper connecting angle, copper briddle wire, ptfe neutral section runner, section insulator runner, copper tubular terminal, discharge valve, copper socket, set of electrode & nozzle & other copper miscellaneousllaneous in bin no-7. qty=3686 kgs. loading will be done by purchaser's own arrangement.
Tender For supply of roof line insulator to clw spec. no.- spec: clw-es-ac-i-1 alt.l,& drawing no.- clw/es/sk-2/ac/i-1/ l. iec drg no- cqs-033-p 055.rev.00 [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For replacement of old aged disc insulator strings with new src insulators in all suspension and tension towers from loc.no.33 to 73 on existing 132kv piduguralla- wadapalli- solid tapped andhra cements dc line in palndau dt. under shutdown condition with 2nd circuit live
Tender For tender for supply of equipment / material , design, erection, testing & commissioning for sop to pump house constructed at jakhota-i (bohal khalsa) under hpshiva project w.r.t. horticulture development block dehra in electrical section bharoli under esd hpsebl no-i jawalamukhi, ed jawalamukhi. - supply part of lt line with aaac 7/3.15 (0.323 km), steel tubular poles 8 mtr. long with base plate, steel tubular poles 9 mtr. long with base plate, muff for steel tubular pole with concrete filling, aaac conductor 7/3.15, 55 sq. mm ( includes 3 conductor length and additional 1% sag (sag, jumpering and wastage)), lt ab cable [size 4x70+1x70+1x16 sq. mm] x 2 cable, pvc (1.1 kv, ai, un-armour 3.5 x 35 sq. mm, single continuous earth wire (g.i wire 8 swg), channel iron (75x40x4.8 mm), length 1.50 mtr + 0.2 mtr}, shackle insulator, d-iron, stay set complete, stay wire, earthing set lt complete in all respect, earth knob, half clamp, full clamp, nuts & bolts off sizes, spiral pvc spacer, aluminium paint, red oxide point, supply part of aug. of 63 kva to 100 kva distribution sub-station, aluminium thimble 120 sq mm, lt cable 3.5 core 120 sq. mm, chain link fencing, angle iron, gate etc. for transformer fencing, 3-ph, 4-wire trivector meter 200/5 a, erection part of lt line, erection charges & transportation charges complete in all respect of lt line, erection part of aug. of 63 kva to 100 kva dtr, erection charges & transportation charges complete in all respect of aug. of 11/0.4 kv, 63 to 100 kva dtr
Tender For tender for supply of equipment/material, design, erection, testing commissioning for sop to pump house constructed at jakhota sasan dhanot under hpshiva project w.r.t. horticulture development block dehra in electrical section adhwani under esd hpse - supply part of lt line with aaac 7/3.15 (0.070 km) sasan, steel tubular poles 8 mtr. long with base plate, muff for steel tubular pole with concrete filling, aaac conductor 7/3.15, 55 sq. mm ( includes 3 conductor length and additional 1% sag (sag, jumpering and wastage)), pvc (1.1 kv, ai, un-armour 3.5 x 35 sq. mm, single continuous earth wire (g.i wire 8 swg), shackle insulator, d-iron, stay set complete, stay wire, earth knob, nuts & bolts off sizes, aluminium paint, red oxide point, supply part of lt line with aaac 7/3.15 (0.325 km) dhanot, steel tubular poles 8 mtr. long with base plate, muff for steel tubular pole with concrete filling, aaac conductor 7/3.15, 55 sq. mm ( includes 3 conductor length and additional 1% sag (sag, jumpering and wastage)), pvc (1.1 kv, ai, un-armour 3.5 x 35 sq. mm, single continuous earth wire (g.i wire 8 swg), shackle insulator, d-iron, stay set complete, stay wire, earth knob, nuts & bolts off sizes, aluminium paint, red oxide point, supply part of aug. of 63 kva to 100 kva distribution sub-station sasan, aluminium thimble 120 sq mm, lt cable 3.5 core 120 sq. mm, surge arrestor 9 kv station, nuts & bolts off sizes, pipe earthing set, 8 swg gi wire for earthing, 3-ph, 4-wire trivector meter 100/5 a, supply part of aug. of 25 kva to 100 kva distribution sub-station dhanot, aluminium thimble 120 sq mm, lt cable 3.5 core 120 sq. mm, surge arrestor 9 kv station, nuts & bolts off sizes, pipe earthing set, 8 swg gi wire for earthing, 3-ph, 4-wire trivector meter 100/5 a, erection part of lt line sasan, erection charges & transportation charges complete in all respect of lt line, erection part of lt line dhanot, erection charges & transportation charges complete in all respect of lt line, erection part of aug. of 63 kva to 100 kva dtr sasan, erection charges & transportation charges complete in all respect of aug. of 11/0.4 kv, 63 to 100 kva dtr, erection part of aug. of 25 kva to 100 kva dtr dhanot, erection charges & transportation charges complete in all respect of aug. of 11/0.4 kv, 63 to 100 kva dtr