Get complete information related to latest Dc Dc Converter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Dc Dc Converter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Dc Dc Converter Tenders.
Tender For procurement of spares for mig-29 upg aircraft - mmic amp . 0.5-6ghz tape&reel, voltage converter 27v -5v, uprk-4-5 one time command trasmission device, power supply module, mgp-20, dual interogator receiver, dual transponder receiver, supply and laser controlling unit
Tender For corrigendum : supply of rs spares of kbi make - oh kit for mean pressure valve mdv1 for apl make kbi , oh kit for stopcock parking acu panel for parking and isolating cock cab pneumatic for apl make kbi , oh kit for 3by2 way cock acu panel and 3 by 2 way cock panto panel for apl make kbi , oh kit for overflow valve dr8 b01.05 acu panel for apl make kbi , oh kit for pressure reducing valve b01.06 acu panel for apl make kbi , oh kit for load limit valve dbv3 e bcu for apl make kbi , oh kit for check valve g1 a07 main air compressor for apl make kbi , oh kit for check valve rv19 t b01.04 acu panel for apl make kbi , oh kit for check valve drv7 t double b01.10 for apl make kbi , oh kit for impulse valve b01.011 acu panel for apl make kbi , oh kit for filter b01.03 acu panel for apl make kbi , oh kit for air filter u03.03 panto contol panel for apl make kbi , oh kit for anti-skid valve for apli make kbi , oh kit for valve magnet for apli make kbi , oh kit for ebmv bcu panel magnet valve panto control panel magnet valve cab for apl make kbi , oh kit for stopcock ahb200 002 b01.02 b01.07 b01.08 acu panel for apl make kbi , oh kit for levelling valve under frame for aplmake kbi , safety valve rs10 make kbi , isolating cock make kbi , magnet valve wmv1zest make kbi , swivel bearing swing trolley small size apl make kbi , support roller of saloon door apl make kbi , power module pom card for dcu door rs3 make kbi , kit for analog converter aw 4.1c for c1chk make kbi , kit for mean pressure valve mdv1 make kbi , kit for anti skid valve gv 18 2 kb make kbi , kit for bcu terminal block make kbi bid number/ & ( * ) : gem/2025/b/6046686 dated/ + : 11-03-2025 bid document/ 3 3 1 / 36
Tender For corrigendum : tender for supply of resistance temperature transmitter and indicator - resistance temperature transmitter ( resistance to current converter) , make -elektra precision .input- rtd pt-200. temperature range 0-100 degree centigrade , output- 04 to 20 ma dc (two no of output) zero & span adjustable. power supply- 118 vac with connector. other detail as annexure-1.(bidder should comply one to one in specification as attached) , spare elektra ( earlier lektrolab ) make resistance temperature transmitter. input rtd pt.200. temp range- 230 - 320 degree centigrade. o/p- 04 to 20 ma dc. single output. other common details as per attached annexure-1. , spare elektra ( earlier lektrolab ) make resistance temperature transmitter. input rtd-pt.200. temp range- 0-320 degree centigrade. output- 04 to 20 ma dc with double isolated outputs. other common details as per attached annexure-1. , resistance temperature transmitter ( resistance to current converter) , make-elektra precision .input- rtd pt-100. temperature range 0-100 degree centigrade , output- 04 to 20 ma dc (two no of output) zero & span adjustable. power supply- 118 vac with connector. other detail as annexure-2.(bidder should comply one to one in specification as attached) , indicating alarm meter , make - m/s elektra precision systems , tag-flow indicating alarm meter , range-0-400 ft/sec , alarm -high , alarm relay-one for high alarm , input -4-20ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag-temperature indicating alarm meter , range-0-100 degree c , alarm -high , alarm relay-one for high alarm , input -4-20ma , mounting arrangement-1a , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- differential pressure indicating alarm , range- -15 to +25 gm/cm2 , alarm -high , alarm relay-one for high alarm , input -4-20ma , mounting arrangement-1a , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- flow indicating alarm , range- 0-700 (squre root scale flow) lpm , alarm -low , alarm relay-one for low alarm , input -10-50ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- temperature indicating alarm , range- 0 to 70 degree c , alarm -low/high , alarm relay-one for high alarm and one for low alarm , input -4-20ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- flow indicating meter , range- 0-6 (squre root scale) klpm , alarm -no alarm , alarm relay-no alarm , input -10-50 ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- level indicating meter , range- 0-10 meter , alarm -no alarm , alarm relay-no alarm , input -4-20 ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- flow indicating meter , range- 0-10.7 meter / sec & 0-30 feet /sec , alarm -high , alarm relay-one for high alarm , input -4-20 ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- flow indicating meter , range- 0-10.7 meter / sec & 0-30 feet /sec , alarm -high , alarm relay-one for high alarm , input -0-4 ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- pressure indicating alarm meter , range- 0-0.7 kg/cm2 , alarm -high/low , alarm relay-one for high alarm & one for low alarm , input -4-20 ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , i
Tender For corrigendum : 05/08/10 work of stopping oil leakage from mva power converter and cleaning damaged wti oti meter oil and replacing damaged packing cock seat.