Tender For supply of 2025-26 (ami no. gr. 33 n37) "hiv1 and 2 flow through immunofilteration method kit, for the detection of hiv-1 & hiv-2 in human serum/plasma. - simple & user friendly test procedure - 100% sensitivity & 100% specificity - confirmatory test for detection of hiv infection, nib or naco approved, pack size - 25 tests/ pack or equivalent" ]
Tender For corrigendum : short term e-bid for rate contract cum supply and empanelment of surgical items - "syphilisantibody (rapid) detection kits1. the assay should be based on rapid chromatographic immunoassay for qualitative detection of antibodies (lgg, lga & lgm) to tp in serum, plasma & whole blood.2. the assay should utilize recombinant treponemal antigens i.e. tp15, tpl7, tp47 against syphilis.3. the assay should be in card format.4. adequate documents detailing the principle components, bio- safety methodologies, validity criteria, interpretation of results, performance characteristics storage conditions, limitation of assays manufacturing & expiry dates should be provides with each kit.5. the kit should have approval of the statutory authority in its country of origin.6. in case of imported kits it should be registered and licensed under the provisions of drugs & cosmetics act and rules and/or medical devices rules 2017 in india.7. in case of indigenous manufacturers should be licensed under the provisions of drugs & cosmetics act and rules and or medical devices rules 2017 issued by the competent authority defined under drugs and cosmetics act, 1940.8. the kit should have minimum shelf- life of 5/6th or 12 months (whichever is more) at the port of discharge of consignees.9. read result time should not be more than 20 minutes.10. assay should have sensitivity 100% & specificity 99 %or more with documentary evidence.11. the storage & transport temperature of the kit should be 2-30 c.12. the pack size should not be more than 50 tests wherein each test is individually", bed side leucodepletion filters for blood transfusion (for 2 unit of red cell) [ne32b] 1. filters should be able to leucodepletered cells form leukocytecontamination separately for 1 unitof red cells and for 2 units of redcells each.2. filters should be having thecapacity of log 4 reduction(99.99%)3. filters should not carry anycharges it should be neutrallycharged.4. filters material should bepolyester woven / non- woven.5. leukocytes should beconsistently averaging less than0.5x105 residual leucocytes forone unit of red cell and 0.2*106for two units of red cell. rbcrecovery should be averaging morethan 90%.6. filters should have hard / softhousing for optical monitoring.7. filtration loss should not bemore than 35 ml for one unit redcell.8. should have integrated 40 m,micro aggregate filter.9. should be us fda/ europeance certified., hepatitis b surface antigen (elisa) testing kits iv generation/high sensitiveshould have microplate elisa coated with either polyclonal or monoclonal antibodies to hbsag and either polyclonal or monoclonal antibodies in conjugate. the assay should be able to detect all the 11 subtypes (ad & ay subtype) including mutant strains. the assay should be able to detect surface antigen to hepatitis b virus., hbsag (rapid test)
Tender For supply of alcohol dehydrated , alcohol methyl , aso kit , bayer keto diastix bott of 50 , blood sedimentation rate pipette westergren , blue star slide microscopic 75 mm x 25 mm x 1 point 35 mm pack of 50 , ca pluse electrode electrolyte analyser roche 9180 , crp kit finecare , cyanmethemoglobin standard , dengue rapid card test ns1 ag pluse igg igm , distilled water , drabkin solution cyanmetheamoglobin method , drug abuse detection kit pack of 25 meriscreen , erba albumin kit 5 x 50 ml code no 120223 for erba chem 7 semi autoanalyser , erba alkaline phosphatase kit 6 x 6 ml code no 120247 for erba chem 7 semi autoanalyser , erba amylase kit 6 x 6 ml code no 120242 for erba chem 7 semi autoanalyser , erba bilirubin total and direct kit 4 x 60 ml code no 120244 for erba chem 7 semi autoanalyser , erba calcium ocpc kit 1 x 50 ml code no 120225 for erba chem 7 semi autoanalyser , erba cholesterol kit 5 x 20 ml code no 120194 for erba chem 7 semi auto analyser , erba ck mb kit 2 x 8 2 x 2 ml code no120848 for erba chem 7 semi auto analyser , erba creatinine kit 4 x 60 ml code no 120246 for erba chem 7 semi auto analyser , erba gamma gt kit 2 x 20 or 2 x 5 ml code no 122135 for erba chem 7 semi autoanalyser , erba glucose kit 2 x 200 ml code no 120200 for erba chem 7 semi autoanalyser , erba h 360 calibrator , erba h 360 clener 50 ml , erba h 360 control , erba h 360 dil 20 ltr , erba h 360 lyse 500 ml , erba hba1c with calibrator kit 2 x15 or 2 x 5 or 2 x 44 or 1 x 44 ml code no 122129 for erba chem 7 semi auto analyser , erba hdl cholesterol kit 2 x 50 ml code no 120227 for erba chem 7 semi auto analyser , erba ldh kit 4 x 8 or 1 x 8 ml code no 120243 for erba chem 7 semi auto analyser , erba lipase eco kit 1 x 20 or 1 x 5 ml code no 121369 for erba chem 7 semi autoanalyser , erba norm kit 1 x 5 ml code no 120219 for erba chem 7 semi auto analyser , erba path kit 1 x 5 ml code no 120221 for erba chem 7 semi auto analyser , erba sgot kit 5 x 20 ml code no 120204 for erba chem 7 semi autoanalyser , erba sgpt kit 5 x 20 ml code no 120207 for erba chem 7 semi auto analyser , erba t ltx crp kit 1 x 40 or 1 x 10 ml code no 131959 for erba chem 7 semi auto analyser , erba thermal paper roll 55 mm for erba chem 7 semi auto analyser , erba toatal protein kit 5 x 50 ml code no 120231 for erba chem 7 semi auto analyser , erba triglycerides des kit 5 x 20 ml code no 120211 for erba chem 7 semi auto analyser , erba urea bun kit 5 x 20 ml code no 120214 for erba chem 7 semi autoanalyser , erba uric acid des kit 5 x 20 ml code no 120216 for erba chem 7 semi autoanalyser , erba wash kit 4 5 ml code no 120232 for erba chem 7 semi auto analyser , glass cover microscope 18 mm square , glass cover microscope 22 mm square , harness maint tubing 918 x pm kit for roche 9180 electrolyte analyser , isetrol control electrolyte analyser roche 9180 , k plus electrode electrolyte analyser roche 9180 , kit for estimation of t3 finecare , kit for estimation of t4 finecare , kit for estimation of tsh finecare , malaria paracheck antigen detection kit , methylene blue stain ready to use , microtips 5 to 200 ul , milk adulteration kit , na plus electrode electrolyte analyser roche 9180 , occult blood test kit 50 test , opticare microscope lens cleaner , pm kit for erba chem 7 semi auto analyser , platelet diluting fluid , pm kit for erba h 360 haemetology semi auto analyser , pm kit for robonik prietest tuch bio chemestry semi auto analyser , prega news upt strip , prothrombin time reagent to give control of 10 to 14 sec vial of 10 ml , pttk reagent with calcium chloride , ra factor kit , rapid papanicolaou stain kit rapid pap bio lab , reference electrode electrolyte analyser roche 9180 , roche 9180 electrolyte analyser thermal paper roll 40 mm , semen diluting fluid , siemens chek stix combo pak positive and negative urine control strips 25 strips per bott , snap pack electrolyte analyser roche 9180 , sodium electrode conditioner electrolyte analyser roche 918
Tender For re e tender for procurement of kits, chemicals and reagents for two years from the date of award of contract (aoc) and its extension, if required - hcv (detection of both ag & ab) elisa kit - 4th gentechnical specification: 1. kit needs to be able to detect both antibody (core, ns3 and ns4) and antigen (capsid) against hepatitis c virus. 2. monoclonal abs against capsid proteins, and recombinant protein or antigens or synthetic peptides for ns3, ns4 and capsid needs to be coated on the solid phase. 3. kits needs to have separate positive control for antigen and antibody. 4. kit needs to have 2 separate conjugates for antigen as well as antibody detection. 5. reagents needs to be colour coded with od norms for reagents addition verification on automation as well as manual procedure due to colour change on addition of samples/reagents in the wells (optional). 6. sample volume needs to be = 50 µl without any predilution step. 7. total incubation time of assay needs to be = 2.5 hrs. 8. kit needs to have sensitivity of 100% 9. kit needs to have specificity of = 99.5% for both antigen as well as antibody without compromising the assay sensitivity. 10. kit needs to be ce approved and certificate of analysis should be provided for each batch of the product 11. kit needs to be programmable & compatible for automated systems. 12. supplier needs to provide the certificate of analysis from nib for each supplied batch. 13. supplier needs to be able to
Tender For tender for supply of equipments as per list in buyer added additional terms and condition -rsp tool kit , blasting machine , drilling machine , hhmd , dragon search light , extension search mirror telescopic inspection mirror , prodder telescopic prodder , under vehicle search mirror , explosive detection kit , grapnel with rope 007a , rakers , trip wire feeler , entrenching tools , rope slithering 08 mm dia length 50 mtrs , rope slithering 06 mm dia length 50 mtrs , vacuum pad single 4 inch dia , vacuum pad double 4 inch dia
Tender For tender for supply of internet of things - arm based single board computer wi-fi + ble development board kit 32-bit arm based development board 32-bit mcu prototyping board temp & humidity sensor ultrasonic sensor air quality sensor pir motion sensor soil moisture sensor relay module (5v, 4-channel) servo motor camera module 5mp voice recognition module (offline) sound detection/microphone sensor module (basic)