Tender For design, manufacturing, testing, supply, installation, commissioning and after sales service o f cab heating unit with de-fogging unit (lh & rh) along with anti-vibration mountings, prewired control pa nel, operating cum indication panel, inter-connecting ducts for defogging unit, air diffuser of defogging unit for wind screen confirming to icf specification spec. no. icf/elec-098, rev.01, cs-01, annexure-1 or latest , suitable for air-conditioned self propelled inspection car (spic ac) coaches. [ warranty period: 30 month s after the date of delivery ]
Tender For empanelment of agencies for supply of laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoridemeter: ph/ise benchtop meter with electrode stable, universal power adapter, literature, pc cable, meter test certificate electrode: ionplus fluoride and nitrate combination ion selective electrode, 1m cable, waterproof bnc benchtop ion meter (ise) along with fluoride, nitrate #electrode range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 relative accuracy 0.002 calibration points up to 5 calibration editing yes #mv/ rmv orp range 2500.0 mv resolution 0.1 relative accuracy 0.2 mv or 0.05 % of reading whichever is greater eh orp mode yes ise range 0 to 19999 resolution up to 3 significant digits relative accuracy 0.2 mv or 0.05 % of reading whichever is greater units ppm, m, mg/l, %, ppb, none calibration points up to 5 calibration editing yes calibration features timed end point, linear point to point, non-linear selectable auto-blank, low concentration range stability #temperature range -5 to 105 c, 23 to 221 f resolution 0.1 relative accuracy 0.1 offset calibration 1-point datalogging memory 2000 with time and date stamp log function manual, ready (include auto-read ), timed log edit delete individual points, group of points or all inputs ph electrode bnc, reference pin atc probe 8-pin mini-din #output rs232, usb power ac adapter included universal, 100-240 vac battery power optional 4 aas battery life 800 hrs, fluoride electrode of ion metersame make that of the ion meter, manifold filtration assembly* wide range of pumps and filtration flasks * high quality components * easily exchangeable elements *maintenance-free * low noise * added filters for enhanced pump longevity * filtration base with silicon stopper, cap & aluminium clamp connecting silicon tube technical specification for filtration flask set # high-pressure resistant tube # fiberglass filter membranes (47mm / 0.1 m) # ptfe disc filter #normal liquid filtration * specification for filtration glass set #suction bottle capacity(ml) 1000 ml # filter diameter(mm) 47/50 mm # * specification for filter flask * material: statinless steel 304, capacity: 300 ml (100 ml each) [ unit should consist of 3 flask so that 3 sample can be filtered simultanelously without any issue] # effective filtration area(cm2) = 9.6 cm2, outlet connector(mm) = 8 mm * specification for vaccum flask: #flow rate of the pump(l/min) = 17 l/minultimate vacuum(mbar) = 150 mbar # oil free, maintainance free, built in thermal protection to shut off when over heated., auto cut heater for distill water plant so that when water level decreases the heater is switch off automatically, voltage stabilizer capacity- 3 kva servo stabilizer 5 star rating, heating mantle (single station) should have digital energy regulator with multiple step power regulation automatic spill detection and saftey shutdown in built precision temperature control technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 420 degree celcius. accuracy: plus minus 1.0 degree celcius, power consumption : 150 w, heating mantle (combined unit) material of construction heating block: made with grade epoxy painted chemical resistant coating, aluminum block with 6 thermo wells for processing 6 different samples at a time. #racks: ss 316 # glassware: teflon coated # temperature range ambient + 10 deg c to 450 deg c # stability of temperature better than 0.5 deg c # controller consist of digital read out of temperature and time with 4 programmable ramps for each method. # number of programmable methods 20 numbers. # heating powers 1000w # heating position minimum 6 position # digestion time range -1 to 999 minutes # the system should have facility of acoustic signal at the end of completion of cycle to notify the operator. # the thermal digestion unit should have high thermal homogeneity # the setup should have small footprint. # th
Tender For corrigendum : annual overhauling of l and t make esp of unit 4,2x660 mw,sstpp,mppgcl,dongalia - cleaning, inspection & alignment rectification of esp passes, internal cleaning of esp fields & hoppers with water washing, preparation of scaffolding and internal inspection for fields, cleaning & inspection of frp & its heating elements, cleaning & inspection of support insulator & its heating elements, alignment of discharge electrode frame (complete frame), repair & replacement of damaged components of esp, replacement / repairing of electrical single impulse (esi) rapping system (inlet gas distribution rapper, modulok collecting electrode rapper, rigitrode discharge electrode rapper)., internal repairing/ replacement of frp, repair/ replacement of support insulators., replacement/repair of g.d. screen., alignment of collecting electrode, repairing of rigitrode discharge electrode, reclamation/ replacement of rapper piston, rapper rod and boot mounting assembly of cerm /derm/ gdrm
Tender For corrigendum : supply of aiir condiitiioniing system - supply charges for mr item no 1.001 , supplycharges for mr item no 1.002 , supply charges formr item no 1.004 , supply charges for mr item no1.005 , site work charges as per mr sl no 02.001 foritem no 1.001 , site work charges as per mr sl no02.002 for item no 1.002 , site work charges as permr sl no 02.004 for item no 1.004 , site workcharges as per mr sl no 02.005 for item no 1.005 , freight charges as per mr sl no 03 , total lumpsumpwcamc charges for 5 years as per mr sl no 12.001for item no 01.001 , total lumpsum pwcamc chargesfor 5 years as per mr sl no 12.002 for item no 01.002, total lumpsum pwcamc charges for 5 years as permr sl no 12.004 for item no 01.004 , total lumpsumpwcamc charges for 5 years as per mr sl no 12.005for item no 01.005 air conditioning system, vrf system, hvac, heatingventilation air conditioning, heating ventilationand air conditioning system, vrf unit, vrf system