Get complete information related to latest Delegate Unit Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Delegate Unit Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Delegate Unit Repair Tenders.
Tender For supply, installation, testing and commissioning of silent d.g. set of 250 kvacapacity complete including civil foundation work with diesel engine, self[1]starter, amf panel and acoustic enclosure etc asper actual site requirement. 250 kva diesel generator set should comply with gsr no. 371 (e) f. no.8-15022/2/2001-cpaenvironment (protection) second amendment rules, 2002 (regarding noise pollution) or latest.the diesel generator sets should conform to cpwd general specifications for electrical works part vii(dg sets) 2013or latest, attached here with and comply with tech spec-ixand other associated work is/ie rules and site requirement &authorized certificate and challan/invoice/test report/warrnty certificate to be submitted with delivery of material. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply, installation and testing of electronic equipments - supply -ece lab equipments, single output regulated dcvariable power supply- input voltage: 230v / 50hz ac. output voltage: (0 30)v dc. output current: (0 2)a dc. protection circuit: over voltage, over current, and short-circuit protection. high efficiency: greater than 85%. low ripple and noise: less than 50 mv. digital display., dual output regulated dc variable power supply- input voltage: 230v/50 hz ac. output voltage: (0 30)v dc. output current: (0 2)a dc. protection circuit: over voltage, over current, and short-circuit protection. high efficiency: greater than 85%. low ripple and noise: less than 50 mv. digital display., function generator - frequency range: 0.1 hz to 5 mhz. display: 4 to 6 digit led display. output waveforms: sine, triangle, square, pulse, ramp. amplitude: 0 20 vpp. rise time: 100 ns. distortion: 1% within specified frequency range. power supply: 230 v ac 10%, 50 60 hz. output amplifier protection: short-circuit and 15 v, digital ic trainer kit with breadboard - +5 v dc, 1 a regulated power supply. 12 v dc / 15 v dc, 200 ma regulated power supply. solderless breadboard with minimum 840 tie- points,power distribution buses. zif (zero insertion force) ic sockets to accommodate 8 or 16 pin ics. logic input and output leds for output monitoring. 16 buffered led outputs. 16 debounced switch inputs. variable clock generator: 0.5 hz to 50 hz. single pulse output: 100 ms (buffered, positive and negative outputs). one seven-segment display with 4 bcd inputs. built-in logic switches. manual clock: debounced push-button (one pulseper press)., dc voltmeter(digital) - dc digital voltmeter - 3 digit led/lcd display, measurement range: 0 20 v dc,accuracy: class 0.5( 0.5 % full-scale), dc ammeter - dc ammeter digital - 3 digit led/lcd display, measurement range: 0 5 a dc,accuracy: class 0.5 ( 0.5 % full-scale), lvdttrainer kit - ac mains power supply: 230 v 10%, 50 hz. fixed regulated dc power supply: +5 v, 12 v / 500 ma. transducer: lvdt. lvdt displacement: 20 mm (40 mm total). displacement scale: linear 20 mm. displacement display: red color 3 digit led display. excitation frequency: 4 khz. excitation voltage: ac variable excitation voltage up to 5 v., strain gauge trainer kit - ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. instrumentation amplifiers with 3 digit display for strain / output voltage. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords and user manual., ask modulation and demodulation kit - message signal1:8-bit variable data,amplitude 5v. message signal 2:debounced data, amplitude low (0) and high (5 v). message signal 3:fixed data 25 khz, 12.5 khz, 6.25 khz, 3.12 khz,amplitude 5 v. carrier signal: sine wave, frequency 200 khz, amplitude 5 v. supply voltage (board): +12 v, +5 v dc. input voltage: 230 v ac, 50 hz. interface connectors: 2 mm banana socket., fpga trainer kit - must use industry-standard mid-range fpga device usb-jtag programmable, compatible with vivado ise (webpack). power supply: 5 v dc through usb or external adapter. on-board peripherals: leds, switches, push buttons, 7-segment display,clock source, gpio / pmod expansion ports, uart, vga / hdmi, usb- uart bridge, usb cable. user manual., measurement scale: a vertical steel meter scale, usually with (1mm) graduations, for precise deflection measurement., accessories: includes a set of slotted weights (e.g., (6times 50g) or similar sets) for incremental loading.
Tender For purchase of non-consumables for ece department - purchase, dual output regulated dc variable power supply input voltage: 230v/50 hz ac. output voltage: (0 30)v dc. output current: (0 2)a dc. protection circuit: over voltage, over current, and short-circuit protection. high efficiency: greater than 85%. low ripple and noise: less than 50 mv. digital display., function generator frequency range: 0.1 hz to 5 mhz. display: 4 to 6 digit led display. output waveforms: sine, triangle, square, pulse, ramp. amplitude: 0 20 vpp. rise time: 100 ns. distortion: 1% within specified frequency range. power supply: 230 v ac 10%, 50 60 hz. output amplifier protection: short-circuit and 15 v overload protection. dc offset: 0 to 10 v adjustable. attenuation: 0 to 60 db., dso (digital storage oscilloscope) bandwidth: 50 100 mhz. sampling rate: 1 gs/s. channels: 2 (minimum). power supply: 100 240 v ac, 50 60 hz. automatic measurements: vpp, vavg, vrms, frequency, period, vmax, vmin, rise time, fall time, +width, width, +duty, duty, etc. horizontal scale: 5 ns/div 50 s/div or equivalent. vertical resolution: 8 bits (2 channelssimultaneously). vertical sensitivity: 1 mv/div 10 v/div (at input). waveform math: +, , , , invert, fft, etc. waveform storage: 16 waveforms or equivalent. communication interface: usb host and usb interface. display: 7-inch color display or equivalent. input impedance: 1 m 2% || 20 pf. accessories: 2 passive probes (1x/10x)., digital ic trainer kit with breadboard +5 v dc, 1 a regulated power supply. 12 v dc / 15 v dc, 200 ma regulated power supply. solderless breadboard with minimum 840 tie points,power distribution buses. zif (zero insertion force) ic sockets to accommodate 8 or 16 pin ics. logic input and output leds for output monitoring. 16 buffered led outputs. 16 debounced switch inputs. variable clock generator: 0.5 hz to 50 hz. single pulse output: 100 ms (buffered, positive and negative outputs). one seven-segment display with 4 bcd inputs. built-in logic switches. manual clock: debounced push-button (one pulse per press)., lvdt trainer kit ac mains power supply: 230 v 10%, 50 hz. fixed regulated dc power supply: +5 v, 12 v / 500 ma. transducer: lvdt. lvdt displacement: 20 mm (40 mm total). displacement scale: linear 20 mm. displacement display: red color 3 digit led display. excitation frequency: 4 khz. excitation voltage: ac variable excitation voltage up to 5 v., strain guage trainer kit ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords and user manual.
Tender For bid to ras supply of modular kill hut shoot house with advanced tgt sys and related ancillaries e e - modular standalone structure of armour wall panels of 10mm ar 500 steel, , bullet trap panelling of all walls of 4 rooms area , tactical breach doors panel in each room of size minimum 7 feet x 4 , window panels of size minimum 4 x 3 feet. , corridor , anti-ricochet flooring , catwalk , shed , sound reduction treatment , noise reduction ear plugs with 2-way communication , portable targets , wall mounted horizontal moving target systems , 3d human figure system , target controller , ventilation system non- ac other than control room based on exhaust fans , lighting system , fire extinguishing system , wiring, electricals fitting, cabling, , audio system communication system , cctv system room and 01 in corridor. , central control room , 125 kva silent generator , chair , table , almirah , mannequin deferent size
Tender For supply of 5 kva diesel generator set specification: diesel generator set 5 kva, single phase, portable type with wheel, no. of cylinder : 1, no. of strokes: 4, rated engine power: 110 % of the required power at stp, capacity of engine (cc): 428 or higher, air cooled, mechanical governor, class of governor a2 or better, speed 1500 rpm, 50 hz, fuel: hsd, fuel tank capacity : 15 ltr, direct injection fuel system, electric start, battery 35 ah or higher, starting voltage 12v, brushless alternator, alternator voltage 230v, manual control panel. compliance to cpcb ii guidelines of emission & noise required. type approval certificate for the specified rating of the power generator from any of the designated agency authorized by cpcb required. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of 5 kva diesel generator set specification: diesel generator set 5kva, single phase, portable type with wheel, no. of cylinder : 1, no. of strokes: 4, rated engine power: 110 % of the required power at stp, capacity of engine (cc): 428 or higher, air cooled, mechanical governor, class of governor a2 or better, speed 1500 rpm, 50 hz, fuel: hsd, fuel tank capacity : 15ltr, direct injection fuel system, electric start, battery 35 ah or higher, starting voltage 12v, brushless alternator, alternator voltage 230v, manual control panel. compliance to cpcb ii guidelines of emission & noise required. type approval certificate for the specified rating of the power generator from any of the designated agency authorized by cpcb required. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of set of following items - 1. provision of noise reducing insulation with sober screen cover on side walls , end walls and roof top / ceiling area in diesel generator set room 183877/c 2. provision of noise dampening paint sp450 on shell body in diesel generator set area on coach no 183877/c [ warranty period: 30 months after the date of delivery ]