Get complete information related to latest Delta Starters Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Delta Starters Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Delta Starters Tenders.
Tender For day to day maintenance and call on repairs for attending breakdowns at south drydock pump house including replacement of unsv items for dol starters star deltastarters metering equipment switch gears digital water sensors fpt systems at drydocks nav
Tender For day to day maintenance and call on repairs for attending breakdowns at north drydock pump house including replacement of unsv items for dol starters, star deltastarters, metering equipment, switch gears, digital water sensors, fpt systems at drydock, naval dockyard visakhapatnam under ge (i) (dm) visakhapatnam
Tender For supply and installation of bera system - supply & installa tion of bera system, software and accessories -(specification mentioned as in the notice inviting tender document), specifications ecochg cortical aep (p100, llr, p300, mmn) am lr, eabr vestibular evoke d myogenic potenti al (vemp) algo rithm for emg rec tification assr, stacked abr (if p ossible). transducers - ins ert earphone s -td h headphone -bon e vibra tor - loudsp eaker stimulus - click (user-selecta ble from choi ces of 50, 100, 150, and 200 use) tone bur st (frequenci es 2 50 to 8 khz, choice of linear, henning, blackman or gaussian stimulus ramps for tone burst). t one pip speech: /p a/, /ta/, / ka/ ce- chirp, ce-chirp o cta ve bands mas king noise: pink a nd white noise p olarity: alternating , condensation, rar efaction intensity: 0 to 130 db spl or more repetition rates: 0.2 100 depending on modality data points: 256, 512, 1024 or more test protocols - unlimited, the system must support th e creation of user-d efined custom protocols capable of calculating a numeric correlation of t wo selected wavef orms to define simi larity between the collected waveforms objectively. c apable of performi ng weighted and unweighted addition and subtraction of selected waveforms. capable of sep arating abrdata c ollected with altern ating polarity stimu lation into its separate rarefaction and condensationwave form components. system must sup port automatic elec trode switching for singlechannel data collection such thatmanual movement of electrodesin the electrode cable is n ot required to colle ct ipsilateral data when changing the stimulus ear. syst em must be capabl e of applying user- specified post hoc digital filters durin g data analysis. s ystem must suppor t simultaneous revi ew of data frommultiple test sessions for the patient in th e same on-screen d isplay and report to facilitate monitorin g for changes over time. system mustprovide a means o f password-protecti ng thetransducer c alibration values to prevent inadvertent editing by unautho rised personnel. t he system should h ave an option for external direct printi ng of the report data export to hl7 protocols along wit h the facility to pro vide free api the system should have compliance with international regula tory standards of c e,fda, and iso. free period cali bration for the first three years and afte r three years of cal ibration along with amc support for5 years to be provid ed at the national i nstitute of speech a nd hearing com puter supplied alon g with the equipme nt needed to meet t he below requirem ents latest wind ows operating syst em processor whi ch is intel i 7 or hig her with clock spee d > 2.5mhz ram>= 8 gb and stora ge space ssd>= 5 00gb minimum 3 usb portsalong with 1 hdmi, 1eth ernet port warrant y of the computer b e three years mini mum equipmen t should be powere d using 240v 5ohz. the connection s hould be type d the software sup plied along with th e hardware should have the provision for free upgradation if a new version l aunches in the mar ket within the next five ye ars of the ins tallation also provide free software up dation and support as operating syste m upgradation hap pens penalty for thedelay in repair and delivery of the equipment and acc essories. the penal ty amount is calcul ated based on 24 h ours / 48 hours, an d 72 hours and if t he supplierdoes no t deliver the produc t within ten days of issuing the purchas e order, they should be blacklisted., cmc/amc cost a fter the completion of 3 years of warranty period ( 7 yearsof amc)
Tender For supply of switchgear items c c - acbs and their spares low tension acb conform to is2516 1965 part i sec and amended itable at 415 volts ac supply rating 400 630a 800a 1000a 1250a 1600a 2000a 3200a 4000a , mccb complete pole with only magnetic release with magnete thermal release breaking capacity 50 ka at 415 v 50 hz rating 10 a to 630 amp , starters dol star delta complete i dol. starters in steel enclosure motor rating ac2 duty 415 v 50hz 3 ph , starters dol star delta complete ii star deltastarters fully automatic in sheet steel enclosure motor rating ac3 duty 415 v 50 hz 3 ph rating 12.5 hp 25 hp 35 hp 50 hp 75 hp 125 hp 250 hp , contractors and their spares suitable for operation on ac supply 50 c or s single phase three phase coil voltage 230 or 440 , lt switch fuse units and their spares switch fuses units on culrical switch board conform to is4047 1967 suitable for operation on ac supply 3 phase 415 volts 50 cs i in open execution , lt switch fuse units and their spares switch fuses units on culrical switch board conform to is4047 1967 suitable for operation on ac supply 3 phase 415 volts 50 cs i in sheet steel housing , lthrc fuses rating 2a to 630a ac supply 3 ph 415 v 40 cs having breaking capacity excluding 80 ka conforming to is2208 1967 i link type , lthrc fuses rating 2a to 630a ac supply 3 ph 415 v 40 cs having breaking capacity excluding 80 ka conforming to is2208 1967 ii dz type cartridge type