Tender For tender for supply of fuel gas forced daft burner assembly : : - fuel gas forced daft burner assembly as per tdc h24065 002 2012 and its enclosures , pilot with ionization rod assembly as per tdc h24065 002 2012 and its enclosures , uv scanner for main flame as per tdc h24065 002 2012 and its enclosures , battery operated portable ignition system with battery charger as per tdc h24065 002 2012 and its enclosures , mains operated igniter with cable as per tdc h24065 002 2012 and its enclosures , mandatory spares as per tdc h24065 002 2012 and its enclosures , pilot flame detection panels with flame relays as per tdc h24065 002 2012 and its enclosures , power distribution panel for scanner as per tdc h24065 002 2012 and its enclosures , flame scanner panel as per tdc h24065 002 2012 and its enclosures , burner local panel as per tdc h24065 002 2012 and its enclosures , burner performance testing as per tdc h24065 002 2012 and its enclosures
Tender For corrigendum : supply of chemistry lab equipment - procurement of chemistry lab equipment, uv visible spectrophotometer equipped with integrating sphereapplicable for both solid and liquid sample, powder sample kit, diffuse reflectance standards of 2%, 5%, 10%, 20%, 50%, 100%, neutral density filter to obtain linearity for transmittance, and pc control(configuration: insight software for instrument along with core i7 processor and 512gb ssd), electronic balancestainless steel weighing plate, measuring range resolution: 0.001 g, weighing capacity measuring range 120 g, parameter 0.001 g readability (1 mg), capacity 120 g, outside size 20.5 cm (8 in.) 35 cm (13.75 in.) 9 cm (3.5 in.) weighing pan diam. 115 mm (4.5 in.), ph meterrecorder output 0 to 10 mv/ph, 0 to 10 mv/100mv (adjustable), ph range 0-14 phph resolution 0. 01, ph temperature compensation 0 - 100 c, mv accuracy 1 mv, magnetic stirrercapacity 1 litre,stirring paddle q-19 9 x 25 mm,dimensions 150 x 220 x 150 mm, with hotplate, capacity 5 litres, double distillation unit1.5 lph, material borosilicate glass with double stage distillation setup, pyrogen free dimension 650 x 630 x 520mm, flame photometergeneral range ppm, serum range meq,i,urine range meq,i,resolution 0.1 ppm / 0.1 meq,curve at accuracy 2% of fsdisplay 128 x 64 graphical lcd average time in-built in software,flame system lpg & dry oil free air,detector photodiode,aspiration time 3 ml per minute,gas control adjustable with knob,flame failure auto detection,gas cut off automatic,ignition system auto ignition,automiseraxial flow type,dimensions instrument: 365 x 245 x 220 mm approx. (lxbxh),pc interface usb power supply 230 v ac 10%, 50 hz, chromatography chambersize 26x13x26 height 26inch material teak wood, potentiometerrange: 0 to 199.9 mvresolution: 0.1 mvrepeatability: 1mvaccuracy: 1 mv 1 digit input impedance :> 1010 ohms operating temperature : 10 c to 50 c display : 3.5 digit bright red seven segment led display with auto polarity indication power : 230 10% ac ,50hz dimensions : 76*275*170 mm (approx.) weight : 2 kg. (approx.) standard accessories glass electrode : 01 no. reference electrode : 01 no. silver electrode : 01 no. platinum electrode : 01 no. dust cover : 01 no. electrode stand & clamp : 01 no. instruction manual : 01 no., polarimetrytouch screen, no warmup time required when instrument turned on, measuring multiple scales, conductivity meterresolution 0.1 ppm voltage 220 v,ec resolution 0.1 temperature range 0-100 c probe conductivity cell weight 1.5 kg auto cell constant measurement manually cell constant =1k dimension 32/23/18cm display type 3 1/2 digit seven segment led display measurable conductivity range in ppm number of ranges 5 power 230-volt main type of temperature compensation manual no. of calibration points 1 temperature compensation auto cond. range 0-1000 m in 5 range 200m*,2m,20m,200m,1000m phase single phase usage laboratory frequency 50 hz power source electric, handy ph, tds, and conductivity meterph range (-) 2.00 to 16.00,ph accuracy 1%,ph resolution 0.01 ph, orp range 1000 mv,orp accuracy 1%,orp resolution 1 mv,conductivity range,0 to 100 ms/cm,conductivity accuracy 2%,conductivity resolution 1 s,tds accuracy 2%,tds resolution 1 ppm,salt range 0 to 50 ppt,salt accuracy 2%,salt resolution 1 ppm,temp range 0 to 100 deg c,temp accuracy 0.2,temp resolution 0.1 deg c,atc yes,power aaa (1.5v) x 4 batteries, printerconnectivity technology usb, networkprinting technology laser special feature automatic document feeder, fast printing, scanner, copier colour blackmodel name laserjet pro mfp m128fnprinter output monochromemax print speed monochrome 20item weight 11100 gramsprinter media size maximum a4, b5, a6, dl, envelope, ups3kva online ups with 1 year batteries warranty
Tender For supply of fsss spares - quartz double lens barrel assembly for scanner with provision to change lens. l=54mm, od = 20mm , silicon fiber optical cable individual strand dia: 0.002'' or equivalent, minimum wave length band of transmission : 400nm -1500nm visible, flexible jacket: as required od flexible jacket material : ss, material: optic glass 83% core 17% clad or equivalent, measuring intensity 80-90% temperature 650 degree celsius , ignitor tips for hea ignitor l=151mm, +/-3mm diameter 18mm mat ss304 center pin electrode 2.2 kv , ignitor rod for hea ignitor, l=113 inches, +/-1 inches, diameter 18mm mat ss304 , prefabricated igniter cable for hea ignitor l = 20 feet, +/- 0.25 feet , optical window for double lens barrel, inner lens od =13 mm and thickness=2mm, outer lens od=14mm , flame scanner assembly with fiber optic cable (solid & flexible portion) mat ss length 110 inches +/- 1 inches , spark gap tube for hea ignitor voltage 2500vdc, mat ceramic type , fiber optical cables flexible pipe thickness 6mm fiber bundle dia 3mm , double lens barrel assembly for scanner with provision to change lens. moc-ss
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - repairing of optical fibre of flame scanner