Web Analytics Made Easy - StatCounter

Depth Gauges Tenders

Get complete information related to latest Depth Gauges Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Depth Gauges Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Depth Gauges Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :41227392 Due date: 11 Aug, 202511 Aug, 2025 NA
Tender For supply of mechanical engineering lab equipment - green sand moulding setup, casting setup and patterns , hot forging equipment , tig welding setup , soldering station, solder, flux , tool makers microscope , combined shear force and bending moment apparatus , steam engine , heat engine , capillary tube , beaker, pipette, electronic balance, thermometer , manometer , differential manometer , working models of surface condenser , working models of centrifugal air compressor , air-conditioning test rig , sling psychrometer , hydrometer , different types of cams, followers and cam/follower arrangements. , various belt drives, chain and sprocket, various gear drives. , different belts in different arrangements , working models of gear trains- all types. (simple, compound, reverted, epicyclical) , various types of brake assemble , various types of clutch assembles , temperature transducer kit , thermocouple , strain gauge kit , smoke detectors and fire alarm systems , solar water heater , sound level meter , solar lighting systems , pressure gauges , thermal conductivity apparatus, metal bar, electric heater, thermocouple , experimental setup for thermal conductivity of insulating material , critical radius of insulating materials apparatus. , pin of apparatus , heat transfer coefficient from shell. and tube heat exchanger , stefan boltzman's apparatus

State Government

CTN :40718241 Due date: 13 Aug, 202513 Aug, 2025 NA
Tender For corrigendum : supply of temperature gauges for 210 mw unit no: 01 to 07 and 800 mw unit no: 08 of wanakbori tps.

Central Government/Public Sector

CTN :41128928 Due date: 29 Jul, 202529 Jul, 2025 NA
Tender For corrigendum : tender for supply of pressure guage and temp indicator for barh and gadarwara : : - pressure gauges for oil module range (-)160-0 mbar , pressure gauges for oil module range (-)60-0 mbar , pressure gauges for oil module range (0-400) bar , pressure gauges for oil module range (0-10)bar , temperature indicator for oil module range (0-100)degc , temperature indicator for oil module range (0-100)degc

Central Government/Public Sector

CTN :40540260 Due date: 30 Jul, 202530 Jul, 2025 NA
Tender For bid to ras corrigendum : supply of temperature gauges - l173219728402001 temp gauge 0 to 60 deg c il 120 mm ibr pack 1 a , l173219728402002 temp gauge 0 to 60 deg c il 160 mm pack 1 b , l173219728402003 temp gauge 0 to 100 deg c il 120 mm ibr pack 1 c , l173219728402004 temp gauge 0 to 100 deg c il 160 mm ibr pack 1 d , l173219728402005 temp gauge 0 to 300 deg c il 160 mm ibr pack 1 e , l173219728402006 temp gauge 0 to 400 deg c il 120 mm ibr pack 1 f , l173219728402007 temp gauge 0 to 400 deg c il 160 mm ibr pack 1 g , l173219728402001 temp gauge 0 to 60 deg c il 120 mm ibr pack 1 h , l173219728402002 temp gauge 0 to 60 deg c il 160 mm pack 1 i , l173219728402003 temp gauge 0 to 100 deg c il 120 mm ibr pack 1 j , l173219728402004 temp gauge 0 to 100 deg c il 160 mm ibr pack 1 k , l173219728402005 temp gauge 0 to 300 deg c il 160 mm ibr pack 1 l , l173219728402006 temp gauge 0 to 400 deg c il 120 mm ibr pack 1 m , l173219728402007 temp gauge 0 to 400 deg c il 160 mm ibr pack 1 n , l173218141102001 temp gauge 0 to 100 deg c il 100 mm pack 2 a , l173218141102002 temp gauge 0 to 400 deg c il 100 mm ibr pack 2 b , l173218141102001 temp gauge 0 to 100 deg c il 100 mm pack 2 c , l173218141102002 temp gauge 0 to 400 deg c il 100 mm ibr pack 2 d , l183419728402001 temp gauge 0 to 100 deg c il 130 mm ibr pack 3 a , l183419728402002 temp gauge 0 to 100 deg c il 160 mm ibr pack 3 b , l183419728402003 temp gauge 0 to 300 deg c il 160 mm ibr pack 3 c , l183419728402004 temp gauge 0 to 400 deg c il 120 mm ibr pack 3 d , l183419728402005 temp gauge 0 to 600 deg c il 160 mm ibr pack 3 e , l183419728402001 temp gauge 0 to 100 deg c il 130 mm ibr pack3 f , l183419728402002 temp gauge 0 to 100 deg c il 160 mm ibr pack 3 g , l183419728402003 temp gauge 0 to 300 deg c il 160 mm ibr pack 3 h , l183419728402004 temp gauge 0 to 400 deg c il 120 mm ibr pack 3 i , l183419728402005 temp gauge 0 to 600 deg c il 160 mm ibr pack 3 j , l184019728402001 temp gauge 0 to 100 deg c il 130 mm ibr pack 4 a , l184019728402002 temp gauge 0 to 100 deg c il 160 mm ibr pack 4 b , l184019728402003 temp gauge 0 to 300 deg c il 160 mm ibr pack 4 c , l184019728402004 temp gauge 0 to 400 deg c il 120 mm ibr pack 4 d , l184019728402005 temp gauge 0 to 600 deg c il 160 mm ibr pack 4 e , l184019728402001 temp gauge 0 to 100 deg c il 130 mm ibr pack 4 f , l184019728402002 temp gauge 0 to 100 deg c il 160 mm ibr pack 4 g , l184019728402003 temp gauge 0 to 300 deg c il 160 mm ibr pack 4 h , l184019728402004 temp gauge 0 to 400 deg c il 120 mm ibr pack 4 i , l184019728402005 temp gauge 0 to 600 deg c il 160 mm ibr pack 4 j , l184619728402001 temp gauge 0 to 60 deg c il 160 mm pack 5 a , l184619728402002 temp gauge 0 to 100 deg c il 140 mm ibr pack 5 b , l184619728402003 temp gauge 0 to 100 deg c il 160 mm ibr pack 5c , l184619728402004 temp gauge 0 to 300 deg c il 160 mm ibr pack 5 d , l184619728402005 temp gauge 0 to 400 deg c il 120 mm ibr pack 5 e , l184619728402006 temp gauge 0 to 400 deg c il 160 mm ibr pack 5 f , l184619728402007 temp gauge 0 to 400 deg c il 220 mm ibr pack 5 g , l184619728402008 temp gauge 0 to 600 deg c il 110 mm ibr pack 5 h , l184619728402009 temp gauge 0 to 700 deg c il 170 mm ibr pack 5 i , jl184619728402001 temp gauge 0 to 60 deg c il 160 mm pack 5 j , l184619728402002 temp gauge 0 to 100 deg c il 140 mm ibr pack 5 k , l184619728402003 temp gauge 0 to 100 deg c il 160 mm ibr pack 5 l , l184619728402004 temp gauge 0 to 300 deg c il 160 mm ibr pack 5 m , l184619728402005 temp gauge 0 to 400 deg c il 120 mm ibr pack 5 n , l184619728402006 temp gauge 0 to 400 deg c il 160 mm ibr pack 5 o , l184619728402007 temp gauge 0 to 400 deg c il 220 mm ibr pack 5 p , l184619728402008 temp gauge 0 to 600 deg c il 110 mm ibr pack 5 q , l184619728402009 temp gauge 0 to 700 deg c il 170 mm ibr pack 5r , l1846s9728402001 temp gauge 0 to 60 deg c il 160 mm pack 5 s , l1846s9728402002 temp gauge 0 to 100 deg c il 140 mm ibr pack 5 t , l1846s9728402003 temp gauge 0 to 100

CTN :41154871 Due date: 28 Jul, 202528 Jul, 2025 NA
Tender For procurement of refrigeration and air conditioning lab equipment for mechanical engineering department. - refrigeration and air conditioning lab equipment, cooling tower test rigexperiment: to determine the efficency of forced draft type coolingtowercooling tower:250 x 250 mm size, height 1000 mm,material: aluminum body with acrylic framepacking sheets: perforated aluminum corrugatedblower : 1hpgeyaser: 3 kw capacityindicator: digital temperature indicator 8 channelthermocouples:1 mtr length, cr. al, wire mesh sheathingair flow measurement: u tube manometer, material glass, size 300mmwater flow measurement: rotameter 0 to 60 cc/seccalibrated water tank : ms, 200 x 250 mm sizestarter: crompton/any reputed make., vapour compression refrigeration test rig compressor type: hermetically shield600 wcooling capacity: 0.3trtechnology: inverter controlrefrigerant: r 600ano of passes: singletube material: copperenergy meter: 1 phase 230 vtemperature sensor: rtd (5 no s)storage space: 591*621*1500 mmcondenser: finned tube typeevaporator: plate typeexpansion valve: capillary coil type, open type air conditioning test rigtechnical specificationstype : single cylindercompressor : 1 tondischarge : 0-10 lphrefrigerant : r 122 or suitablecondenser details : air cooledevaporator : 10 litre capacityno of passes : singleouter tube dia : 6mmexpansion device : capillary tubepressure drop : 0.5 kgf / cm2tube material : copperfan (230 volts 2 amps) : one no (for condenser)freezer box : evaporator unit consists of a ss freezerenergy meter : single phase 230 voltstemp. measurement : 5 no s rtd sensor will be provided to measurethe temperature pointtemperature indicator: 8 channel digital temperature indicator with selector knob to change the temperature point.the whole set-up is ingeniously designed and schematically arranged on apowder-coated rigid structure, recirculating air conditioning test rigcapacity: 1.0 tr compressor: hermetically sealed. condenser: forced convection air cooled.condenser fan:axial flow.drier/ filter: provided.expansion device:capillary tube.evaporator:forced convection air cooled.evaporator fan: axial flow typerefrigerant:r-22.hp / lp cut-out:alco/ or danfoss / or indfoss or any equivalent make.temperature: 6 channel facilities with digital display.pressure:2 nos.; dial type pressure gauges.air flow measurement: by inclined tube manometersupply:220-240 volts, 50 hz, 1 phase.input power: provided for compressor and heater.list of experiments:cooling of fresh air with full exhaust. (summer experiment)heating of fresh air with full exhaust. (winter experiment)humidification of air.cooling or heating the air with partial recirculation.(calculations for mixing of two air streams having different characteristics.)cooling of air with full re-circulation (operation of the system as a window air conditioner.)

Central Government/Public Sector

CTN :41055028 Due date: 31 Jul, 202531 Jul, 2025 NA
Tender For corrigendum : providing of operation and maintenance of other machines and plants - operation and maintenance of other machines and plants - instrumentation contract for miscellaneous instrumentation jobs-10 installation of direct type pressure gauge, temperature gauge, rotameters, flow gauge,etc. including transportation from the wh/iw, necessary tubing, connection etc. but exclusive of supply of materials. 100 nos., 20 installation of direct type pressure transmitter, pressure switch, temperature switch, solenoid valve ( inch to 1 inch), ip converter, thermocouple, rtd, limit switch, position transmitter, vibration transmitter, proximity/ vibration probe, temp. transmitter,speed probe etc. including transportation from the wh/iw, necessary tubing, connection, cable glanding, ferruling, lugging etc. as applicable but exclusive of supply of materials. 320 nos., 30 installation of diaphragm/ remote seal type pressure gauges etc. with accessories including transportation from the wh/iw but exclusive of supply of materials. rating : upto 600# flange rating. 20 nos., 40 installation of diaphragm/ remote seal type pressure transmitter, pressure switch etc. with accessories including transportation from the wh/iw, mounting, connection, cable glanding, ferruling, lugging etc. as applicable but exclusive of supply of materials. rating : upto 600# flange rating. 20 nos., 50 installation of level switch, displacer type level transmitter etc. with accessories including transportation from the wh/iw, mounting, connection, cable glanding, ferruling, lugging/ termination etc. as applicable but exclusive of supply of materials. rating : upto 600 # flange rating. 10 nos., 60 installation of tank level transmitters radar/servo with accessories including transportation from the wh/iw, mounting, gi earthing,glanding,termination etc. but exclusive of supply of materials. 5 nos., 70 installation of instrument control valve with accessories including transportation from the wh/iw, mounting, tubing, connection, cable glanding, ferruling, lugging/ termination etc. as applicable but exclusive of supply of materials. valve size : upto 2"300# 20 nos., 80 cable laying testing of frls armoured power/control/signal cables made trenches,cabletrays, pullthrough pipes or exposed on wall. beam/rakes; trussestie/beam or embedded in floor. unit rates quoted for installation of cables shall be same irrespective of route and method of laying. the rates shall include laying, pulling of cables, proper dressing of cables on cable trays, racks, vertical raceways and supply and installation of saddles, spacers and nylon chord for tying as required, identification tags at strategic points / every 50meter intervals, aluminium clamps with fasteners,etc. cable identification aluminium tags at strategic points/every 50meter interval for identification of cable;etc. complete. the straight through joints/tying with armour in the cables should be avoided and rate includes all leads and lifts from and to yard. meggaring to be done before laying of cables.laying of instrumentation/fo armoured cables/power cables including transportation,dressing , clamping (with aluminium clamp at 600 mm interval), tagging (engraved on ss plates with ss tiebelts), inclusive of supply of consumables like cable tie, aluminium clamp and cable tag : type and size: armoured , od : upto 0.5" ( approx.).exclusive of supply of cables, 22500 meter, 90 cable laying testing of frls armoured power/control/signal cables made trenches,cabletrays, pullthrough pipes or exposed on wall. beam/rakes; trussestie/beam or embedded in floor. unit rates quoted for installation of cables shall be same irrespective of route and method of laying. the rates shall include laying, pulling of cables, proper dressing of cables on cable trays, racks, vertical raceways and supply and installation of saddles, spacers and nylon chord for tying as required, identification tags at strategic points / every 50meter intervals, aluminiu

corporations/Associations/Others

CTN :41123532 Due date: 02 Aug, 202502 Aug, 2025 NA
Tender For ttps es circle instn ii unit v removing cleaning flushing and refixing of bearing temperature heat gauges critical transmitters in boiler and turbine areas disconnection and reconnection of power and control cables of actuators limit switches feedba

corporations/Associations/Others

CTN :41123651 Due date: 02 Aug, 202502 Aug, 2025 NA
Tender For ttps es circle instn ii removing cleaning flushing and refixing of bearing temperature heat gauges critical transmitters in boiler and turbine areas, disconnection and reconnection of power and control cables of actuators, limit switches feedback ca

State Government

CTN :40950747 Due date: 28 Jul, 202528 Jul, 2025 1.77 Crore
Tender For corrigendum : supply, installation, testing and commissioning of 2 no. chillers with cooling tower in central ac plant of main hospital at skims soura - sitc of vfd based, ahri/ eurovent certified, water-cooled, mono/ twin screw type chiller of capacity not less than 100 tr with allied items. the item shall be complete and ready to be connected with main headers in the existing central air conditioning plant of skims soura. the chiller shall be accompanied with microprocessor based control panel with all safety, switch gears needed for safe, smooth and hassle-free operation. the job includes laying of foundation as per oem recommendation which shall be not less than 6 inches above the finished floor level. the technical specifications are further detailed in annexure b., sitc electric-motor driven centrifugal pump for condenser and chiller sides having a discharge of 15 to 18 litres per second, head of 30 metres, 1450 rpm. the technical specifications are furhter detailled in annexure b., insulated chilled water piping (nitrile rubber insulation)supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 kg/ cum density, thermal conductivity 0.037 w/mk or better at 20 deg mean temperature class o insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect.note: the pipes of sizes 150mm & below shall be m.s. c class as per is: 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per is: 3589, from minimum 6.35mm thick m.s. sheet for pipes upto 350 mm dia., 300 mm (32mm nitrile insulation thickness), 250 mm (32mm nitrile insulationthickness), 150 mm (32mm nitrile insulationthickness), 125mm (32mm nitrile insulation thickness), 100 mm (32mm nitrile insulationthickness), 80 mm (32mm nitrile insulation thickness), 65 mm (32mm nitrile insulationthickness), sitc of butterfly valves with di body double flanged construction with epdm coated disc with long pitch and pn 16 pressure rating as per is 13095 (1991), 250 mm , 150 mm , 125 mm , 100 mm , 80 mm , 65 mm , providing and fixing of aluminum cladding of 0.63 mm thick sheet to the insulated pipelines including bends, valves, fittings, etc. the job includes grooving, providing and fixing of screws, washers etc. as per is : 2676 - 1981, 300 mm (32mm nitrile insulation thickness), 250 mm (32mm nitrile insulation thickness), 150 mm (32mm nitrile insulationthickness), 125mm (32mm nitrile insulationthickness), 100 mm (32mm nitrile insulation thickness), 80 mm (32mm nitrile insulationthickness), 65 mm (32mmnitrile insulation thickness), sitc of ductile iron non-return valve of following size with allied jobs as per site requirement. the valve shall be conforming to is-5312. pressure rating : pn16, 150 mm , 125 mm , 100 mm , sitc of y-strainer (ci) flanged end, of following size with allied jobs as per site requirement. pressure rating : pn16, 150 mm , 125 mm , 100 mm , 80 mm , sitc of balancing valve (ductile iron) of following size with allied jobs as per site requirement. pressure rating : pn16, 150 mm , 125 mm , sitc of t-strainer (c.i.) of following size with allied jobs as per site requirement. pressure rating : pn16, 250mm , sitc of fully stainless steel pressure gauge (bourdon beryllium copper, socket ss316l, case and bazel ss304), rugged construction with epdm blowback, safety glass. 0-40 kg/cm , dual display bar/psi or selectable, sitc in position the bi-metal dial thermometer temperature guage 4 dail size bsp (m) connection, ss case and ss wetted parts completer as required, sitc of air release valve of following size. air release valves shall be provided at all higher points in piping system for venting., 25

State Government

CTN :40780607 Due date: 28 Jul, 202528 Jul, 2025 7.47 Lacs
Tender For corrigendum : supply of pressure gauges & temperature gauges for unit 3 to 6, ukai tps.( et-6000 imd-ii)
 Loading, Please wait...

Connect us via What's Up