Get complete information related to latest Deuterium Lamp Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Deuterium Lamp Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Deuterium Lamp Tenders.
Tender For procurement of material and hiring of labour for day to day maintenance of various electrical installations in municipal parks and buildings in ward 140 inderpuri under kbz - supply of 1.5 sq. mm isi marked, frls pvc insulated,single core copper conductor cable as required., supply of 4.0 sq. mm isi marked, fr pvc insulated, single core copper conductor cable as required., supply of 63 amps., 2 pole isolator as required., supply of 6 a, to 32 a, ratings, dp mcb, "c" curve, 10 ka breaking capacity as required., supply of 6a to 32 a ratings, sp mcb, "c" curve, 10 ka breaking capacity as required., supply and fixing of 32mm dia x 1 meter long g.i. pipe (medium class) bracket for mounting of fluorescent/hpmv/hpsv street light fitting on pole including bending the pipe to the required shape , 2 nos 25mm x 6mm flat iron clamps with nuts, bolts and washer , painting the flat iron with primer and finish paint etc. as reqd., supply of xlpe insulated pvc sheathed al. conductor un-armoured cable 1.1kv grade conforming to is-7098 of following size:- 2x 6 sqmm, supply of xlpe insulated pvc sheathed al. conductor armoured cable 1.1kv grade conforming to is-7098 of following size:-2c*10 sqmm, supplying, lowering, testing and commissioning of vertical type, multistage, totally enclosed water filled deep well submersible pumping set complete i/c connection etc. as reqd. (c) three phase 5.0 hp having discharge of 300 lpm approx. at 39 m head., providing following labour for day to day maintenance of ward i/c required t&p etc. in one shift in a day on all working days (required maintenance material will be provided by department) as required as per terms & condition of the department (excluding parts) complete as required. 1. skilled labour", providing following labour for day to day maintenance of ward i/c required t&p etc. in one shift in a day on all working days (required maintenance material will be provided by department) as required as per terms & condition of the department (excluding parts) complete as required. 1. un-skilled labour", supply of led street light fixture, powder coated pressure die cast aluminium body (system lumen efficacy 120 135 lm/watt) of following body materials. - 45 watt
Tender For corrigendum : supply of materials for maintenance work at 132kv sub station ghatampur under etd-ii kanpur - jaw assembly suitable for 36kv isolator, rating 2000a made of copper strip, aluminium strip, ms housing with spring nut and bolt as per sample., daw assembly suitable for 36kv isolatorrating 1250a made of copper strip, aluminium strip, ms housing with spring nut and bolt as per sample., terminal connector suitable for 36kv ct terminal rod and other end twin zebra conductor. made of lm-6 aluminium alloy with galv. nut & bolts. as per sample., 132kv special type isolator bi-matellic terminal connector (dropper/runthrough type) 50mm dia. and moose conductor as per sample., terminal connector suitable for 36kv ct terminal rod and other end twin panther conductor. made of lm-6 aluminium alloy with galv. nut & bolts. as per sample., terminal connector suitable for 36kv vcb one end terminal plate and other end twin zebra conductor made of aluminium alloy. with galv. nut & bolts. as per sample., terminal connector suitable for 36kv vcb one end terminal plate and other end twin panther conductor made of aluminium alloy. with galv. nut & bolts. as per sample without holes., terminal connector suitable for 36kv rama make isolator jaw plate size 80x80mm & 12mm thick and other twin panther conductor made of lm-6 aluminium alloy with gal. nut & bolts., multipurpose cleaner dc 2-26 spray type 400ml pack of standard make., 400 watt hpsv ballast suitable for high mast light fitting., termminal connector for 132kv pt suitable for panther conductor made of all alloy lm-06 completer with nut-bolt and washer as per sample., indication led ryb (24-110v) ac/dc standerd make suitable for control panle., silica gel 6-12mm granules of blue colour, sealed pack packing., terminal connector suitable for 36kv rama make isolator jaw plate size 80x80mm & 12mm thick and other twin zebra conductor made of lm-6 aluminium alloy with gal. nut & bolts., nut bolt with washer size 10x50 mm (gi), nut bolt with washer size 12x50 mm (gi), nut bolt with washer size 10x65 mm (gi), nut bolt with washer size 12x65 mm (gi), terminal connector lm-06 all. alloy suitable for 132kv ct heptacare make other end twin panther conductor with gi nut & bolt as per sample., terminal connector made of lm-6 alloy suitable for 33 kv g.nandy make solator jaw plate and other end twin panther conductor with galv. nut, bolts & washer as per sample., cb clamp 145 kv suitable for panther conductor with galv. nut & bolts., supply of female contact for 145kv rama make isolator as per sample., supply of male contact for 145kv rama make isolator as per sample.
Tender For supply of machinery and equipment - uv-vis spectrophotometer spectrophotometer should be of true double beam optics system. sample compartment should have dedicated one reference cell holder and one sample cell holder. system should be czerny-turner monochromator with lo-ray-ligh grade blazed holographic grating or equivalent. system should have a light source of 20-w halogen lamp and deuteriumlamp. automatic switch over of light source to be possible and auto position adjustment. system should have a fixed spectral bandwidth of 1nm. system should have facility to use as stand-alone keyboard-display and with pc-controlled software. wavelength range should be from 190 nm to 1100 nm and wavelength accuracy should be 0.1 nm at d2 656.1 nm & 0.3 nm for entire range. stray light: less than 0.02% at 220 nm (nai)less than 0.02% at 340 nm (nano2) less than 0.5% at 198 nm (kcl) photometric range:absorbance: -4 to 4 abs transmittance: 0% to 400% system should have photometric accuracy : 0.002 abs at 0.5 abs 0.004 abs at 1.0 abs 0.006 abs at 2.0 abs(measured using nist930d/nist1930 or equivalent) system should have a baseline flatness: less than 0.0006 abs (1,100 to 190 nm, one hour after light source turned on) system should have a noise level: less than 0.00005 abs (700 nm). detector should be silicon photodiode only. system should have a usb drive port to connect the printers or external drives. system should compulsorily have bio-method mode of measurement for determining dna and protein concentrations. quantitates dna or protein using the absorbance at 260/230nm. system should be capable of identification of organic compounds, chemical reaction tracking and enzyme reaction measurement. pc with relevant hardware including monitor keyboard, mouse., fuming hoods the proposed floor-mounted aerodynamic fume hood (1800 1000 2350 mm) is designed for safe handling of hazardous fumes, ensuring high performance, durability, and compliance with international standards. the system should be a robust, corrosion-resistant, and safety-compliant solution with efficient airflow management, user-friendly maintenance features, and adherence to international laboratory safety standards ideal for advanced research and chemical handling applications.1) design & compliance aerodynamic structure with automatic bypass airflow system. conforms to ashrae 110:2016 / en 14175 standards, including tracer gas containment test. certified ashrae compliance required 2) construction & materials made of powder-coated galvanized iron (gi, 120 gsm, is 277 compliant) sheet thickness: 1 mm (1.2 mm for structural supports) heavy-duty base frame: 60 40 2 mm phenolic resin (6 mm) inner liner: chemical-resistant, smooth, easy to clean ss 304 worktop with 15 mm raised edges for spill containment ss 304 aerodynamic airfoil with anti- corrosive coating 3) dimensions & workspace usable workspace: 1500 mm (w) 850 mm (d) 1180 mm (h) clear viewing height: 1100 mm modular base cabinets with maintenance access 4) coating & finish 8-stage chemical pre-treatment epoxy polyester / polyurethane coating (70 80 microns) corrosion resistance validated by 1000-hour salt spray test 5) functional features vertical sliding toughened glass sash (4 5 mm), counterbalanced openable front top panel for easy maintenance aerodynamic baffle system for efficient fume removal (light to heavy fumes) flow control damper for airflow regulation 6) utilities & safety integrated gas, water, and electrical fittings in corner posts remotely operated, color-coded service valves safety partition between utilities no cable entry below sash (enhanced safety design) electrical fittings: norysis /legrand (230v, 5/16a, 50 hz) 7) accessories pp cup sink with water tap and drainage led lighting with protective enclosure adjustable leveling screws ( 10 mm) storage base cabinets with shelves and self-closing shutters 8) centrifugal blower specifications remote, silent ms + frp blower with chemical-r
Tender For auction sale of scrap electrical fitting light - hpsv fitting,scrap from works / products wire rope slingcrain rope scrap,scrap miscellaneous ms steel,scrap drum/ barrel pvc,scrap paint tin ms from works / products empty paint tin 20 ltrs
Tender For provision of new led street lights with allied accessories on existing poles at various dark spots in saidulajab ward no 160 under south zone - led street light fixture, powder coated pressure die cast aluminium body (system lumen efficacy >135 lm/watt). supplying, installation, testing & commissioning of street light led fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with driver efficiency >85%, input voltage: 140-270 volt ac, frequency 50/60 hz, operating temp range -5 0c to 50 0c, internal surge protection of 5 kv l,n,e as per iec 61000-4-5, driver efficiency >85%,thd 10% as per iec 61000-3-2, p. f. 0.95, ip-66,ik-10, cri >70, under voltage and over voltage protection, emi-emc as per cispr-15, lenses for beam angle as per iesna type i/ii/iii as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (led,driver & electrical circuitary) of minimum 50000 burning hours with 70% of initial lumen maintained till life ends as per lm80 extrapolation ies tm-21-11 report, cct 3000 k / 4000 k / 5700 k /6500 k (as per ansi bin), sdcm(standard deviation color matching)5, maximum power consumption should not more than the specified rating and fixture shallbe of relevant bis standard complete in all respect i/c external connections with 1.5 sq mm frls/hffr, pvc insulated copper conductorsingle core cable and earthing etc. as required withminimum 5 year oem warranty. system lumen efficacy >135 lm/watt output . lm79 & lm80 testreport and all testing required for led fixturesas per bis shall be submitted.. shape size and cct shall be as approved by engineer-in-charge asper requirement. (thermal management: heat sink of aluminium housing such that led junction temperature shall not rise above 90 c). 45 watt , supply and fixing of 32mm dia x 1 meter long g.i. pipe (medium class) bracket for mounting of fluorescent/hpmv/hpsv street light fitting on pole including bending the pipe to the required shape , 2 nos 25mm x 6mm flat iron clamps with nuts, bolts and washer , painting the flat iron with primer and finish paint etc. as reqd, supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 3 x 1.5 sq. mm, supply of xlpe insulated pvc sheathed al. conductor un-armoured cable 1.1kv grade conforming to is-7098 of following size:-2c*4 sqmm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required. upto 35 sq. mm
Tender For provision of led light fittings with accessories at various locations in ward no. 167 khanpur, under south zone. - supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 3 x 1.5 sq. mm, supply and fixing of 32mm dia x 1 meter long g.i. pipe (medium class) bracket for mounting of fluorescent/hpmv/hpsv street light fitting on pole including bending the pipe to the required shape , 2 nos 25mm x 6mm flat iron clamps with nuts, bolts and washer , painting the flat iron with primer and finish paint etc. as reqd., supply of xlpe insulated pvc sheathed al. conductor un-armoured cable 1.1kv grade conforming to is-7098 of following size:-2c*4 sqmm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required. upto 35 sq. mm, led street light fixture, powder coated pressure die cast aluminum body (system lumen efficacy 135 lm/watt) supplying, installation, testing & commissioning of street light led fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with driver efficiency >85%, input voltage: 140-270 volt ac, freq 50/60 hz, operating temp range -5 deg centigrade to 50 deg centigrade, internal surge protection of 5 kv l,n,e as per iec 61000-45, driver efficiency >85%,thd 10% as per iec 61000-3-2 , p. f. 0.95, ip66,ik-10, cri 70 , under voltage and over voltage protection,emi-emc as per cispr-15, lenses for beam angle as per iesna type i/ii/iii as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (led,driver & electrical circuitry) of minimum 50000 burning hours with 70% of initial lumen maintained till life ends as per lm80 extrapolation ies tm-21-11 report , cct 3000 k / 4000 k / 5700 k /6500 k (as per ansi bin) , sdcm(standard deviation color matching) 5, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard complete in all respect i/c external connections with 1.5 sq mm frls/hffr, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy 135 lm/watt output . lm79 & lm80 test report and all testing required for led fixtures as per bis shall be submitted. shape size and cct shall be as approved by engineer-in-charge as per requirement. (thermal management: heat sink of aluminum housing such that led junction temperature shall not rise above 90 c). 45 watt