Get complete information related to latest Dew Point Meter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Dew Point Meter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Dew Point Meter Tenders.
Tender For supply, installation, testing and commissioning of electro-magnetic flow meter with necessary accessories and maintenance & repair five year at sarita and charedi inlet line under under 24x7 water supply project under gandhinagar smart city and amrut mission
Tender For running maintenance of plc system - running preventive and breakdown maintenance of plc control system with electrical drives all control and instrumentation system of ash handling , replacement new erection of impulse line , replacement new erection of instrument fitting adopter nut tails elbow connector etc , overhauling b 501 and b 601 ss cock valve , overhauling repairing of junction boxes , servicing recalibration erection of fuzi yokogava rosemount etc transmitters , overhauling and recalibration new erection of digital indicators , overhauling and recalibration erection of flow meter conductivity meter , complete overhauling erection of level switches , replacement of pressure switch gauge vibration switch , removal testing erection commissioning calibration of temp gauges switches thermocouple , replacement erection overhauling cleaning of union isolating valveforged body valve , blowing of tapping points of different pressure transmitters switches , fabrication repairing of instruments plateform , laying patrolling of instrumentation cable , servicing and maintenance of air conditioner , cleaning of control room plc system , repairing of ups , service replacement of faulty butterfly valves along with act , servicing replacement of faulty diaphragm type valves , changing spindle gland of root valves , cleaning blowing by air of impulse lines , attend leakage from steam water air line , replace gauges switches of pressure temp , testing caliberation of pressure gauges , testing calibration of pressure switches , testing calibration of temp gauges , testing calibration of temp switches , replacement of thermocouples , cleaning servicing of terminal block in compressor house swas system , changing of ss root valves , servicing of 10mm hp lp 3way manifold valves , replace of 10mm hp lp 3way mfold valves , removal choking replace of impulse line , erection replacement of pvc armored compensate cable , replacement of universal digital indicator , servicing replacement of faulty 4way valve with actuator , replacement remounting of smps 24 v dc , dismantling replacement of combination timerof compressor , servicing of sampling cooler dhx18 sco2 , servicing of sampling cooler dhx12 sco2 , servicing of sampling cooler dhx06 sco1 , miscellaneous mechanical febrication , maintenance of actuator of butterfly valve , maintenance and upkeep of terminal box of motor of actuators in cw pump , maintenance re erection of butterfly valve actuator motor , revisioning and upkeep of marp dcs panel , revisioning testing of various type of switches of local control panel , maintenance revisioning upkeep and testing of 415 v power supply module , maintenance upkeep and repair of junction box of butterfly valve , servicing of mov motors actuators and limit switch assembly , checking cleaning and cable dressing mov motor , overhauling cleaning reconditioning of various size batteries , load test once in six months for various size battery of ups installed for 5x200mw , replacement of damaged switches mcb in acdb panel , cleaning painting of the wooden battery stands , maintenance of window type split type ac , gas charging of ac , rewinding of burnt fan motor
Tender For design, supply, erection, testing and commissioning of air dryer test bench . test bench should comply with rdso tc no. rdso/2011/el/tc/0108, rev-0, dated 07.03.2011 and the technical specification enclosed in annexure-a. pressure dewpointmeter should be used in the test bench. the test bench should have data storing facility up to 12 months. the air dryer test bench should be plc-based model andshould have data acquisition dedicated software, digital display and printing facility. [ warranty period: 30 months after the date of delivery ] ]
Tender For providing of repair and overhauling service - repair/ refurbishment, upgradation and installation of alternative pump testing facility; as per scope of work; no; buyer premises repair of 03 nos. electromagnetic flow meter, lining hard rubber, fluid fresh water, size dn 200. flow up to 350 m3/hr.