Web Analytics Made Easy - StatCounter

Di Pipeline Laying Tenders

Get complete information related to latest Di Pipeline Laying Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Di Pipeline Laying Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Di Pipeline Laying Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45726596 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif

Central Government/Public Sector

CTN :45741638 Due date: 14 Jul, 202614 Jul, 2026 NA
Tender For providing of custom bid for services - 200155022 biennnial rate contract for running & breakdown maintenance and overhauling of pf piping bends & g feeder of milling system stage i 5x200 mw & stage ii 2x500 mw ntpc singrauli

CTN :45738025 Due date: 21 Jul, 202621 Jul, 2026 NA
Tender For supply of manufacturing and supply of piping system and associated items

CTN :45738502 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; installation of permanent piping system for resin removal and loading from sssb water purification ion exchange column for remote handling of resin in fue..

CTN :45733528 Due date: 10 Jul, 202610 Jul, 2026 37.68 Lacs
Tender For installation of permanent piping system for resin removal and loading from sssb water purification ion-exchange column for remote handling of resin in fuel building of pfbr

CTN :45467505 Due date: 02 Jul, 202602 Jul, 2026 15.00 Lacs
Tender For corrigendum : supply of sitc revival rectification commissioning of phase 1 system 1 and system 3 including receivers tracking piping insulation mirrors and all accessories , sitc steam generation monitoring system pressure tempreature steam flow data logging scada dashboard reporting trainning , cmc for 1 years comprehensive including preventive and breakdown maintenance reporting calibration and sla compliance , cmc for 2 years comprehensive including preventive and breakdown maintenance reporting calibration and sla compliance , cmc for 3 years comprehensive including preventive and breakdown maintenance reporting calibration and sla compliance , cmc for 4 years comprehensive including preventive and breakdown maintenance reporting calibration and sla compliance , cmc for 5 years comprehensive including preventive and breakdown maintenance reporting calibration and sla compliance

CTN :45716570 Due date: 08 Jul, 202608 Jul, 2026 NA
Tender For supply of grd filters , diversion of overflow arrangement , excavation , piping and fitting , supply of diversion of overflow , construction of recharge pit , supply and installation of end cap , drilling of borewell , installation of rainwater harvesting system

Central Government/Public Sector

CTN :45566078 Due date: 29 Jun, 202629 Jun, 2026 11.36 Lacs
Tender For corrigendum : supply of 20 hp outdoor vrv or vrf , 4 way 2.0 tr vrf cassette indoor , 4 way 1.3 tr vrf cassette indoor , y joints , installation of 20 hp vrv or vrf outdoor , installation of 2.0 casssette vrf indoor , installation of 1.3 casssette vrf indoor , commisioning of complete vrf system , refrigerant piping 28.6 mm , refrigerant piping 22.2 mm , refrigerant piping 19.1 mm , refrigerant piping 15.9 mm , refrigerant piping 9.5 mm , drain pipe 32 mm , drain pipe 25 mm , control and transmission wiring , ms sloted angle for pipe paying , outdoor stand for vrv or vrf 20 hp

Central Government And Public Sector

CTN :45698314 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For supply of set of pipe fittings for demu dpc brake system comprising of 34 items as per drawing no.:- dmu/dpc7-3-5-751 (layout of ep brake piping for high horse power diesel multiple unit/dpc coaches) as per annexure attached. [ warranty period: 30 months after the date of delivery ] ]

CTN :45048307 Due date: 31 Jul, 202631 Jul, 2026 NA
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp
 Loading, Please wait...

Connect us via What's Up