Get complete information related to latest Diagnosis Study Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Diagnosis Study Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Diagnosis Study Tenders.
Tender For providing of custom bid for services - drawing and analysis of ambient air/effluent water/drinking water/surface water samples monitoring by environmental laboratory
Tender For tender for supply of logbook - urea analysis register (lab) , wtp/sgp (lab) , raw material register (lab) , bag testing (lab) , neem oil analysis (lab) , natural gas analysis (lab) , log book (lab) , cooling water register (lab) , raw data register - neem urea analysis l , draft test report pad -urea (lab) , draft test report pad -water (lab) , attendance register (lab) , urea requisition slip pad (lab) , water requisition slip pad (lab) , map analysis register (lab) , methanol analysis register (lab) , plant oil analysis (lab) , logbook (lab) , waste water register (lab)
Tender For providing of service contract for "water treatment package which includes supply of chemical formulation for condenser cooling water treatment (ccwt) for ndcts and idcts re-circulating water of both the units and technical & non-technical assistance for the collection and analysis of samples from various systems for different parameters for 02 years"
Tender For corrigendum : supply of upgradation of steam and water analysis system for 210 mw , scada for remote monitoring system in centralized control room , design, engineering, installation & commissioning, testing & handing over of steam and water analys , comprehensive maintenance contract of swas u# 1 to 4 and scada system for remote monitoring at cent
Tender For providing of hiring of consultants - provn of af share of works services for mrsam at af stn vadodara - material and labour for conducting soil investigation by drilling boreholes dia 150 mm and depth 06 point 0m or at which further boring is restricted refusal occurs due to encounter of very stiff soil comma ground or rock etc collecting samples disturbed and undisturbed and carrying out standard penetration test spt and report following details one bore log data up to 06 point 0 mtr two spt result n values at every 0 point 50m intervals and change of strata three soil classifications fourth atterberg limit fifth value of cohesion c and angle of internal friction sixth depth ground water table gwt in peak monsoon lowest and peak summer highest after correlation of result with seasonal variation of water and table in the station seventh swelling properties if any and remedial measures eight sbc at different depth of foundation i e 0 point 9m comma 1 point 0m comma 1 point 20m comma 1 point 50 m comma 1 point 75m and 2 point 0m etc alonwghwith under mentioned details one all the bore holes two sbc should be worked out for following size of footing 1 point 5 into 1 point 5m 1 point 5 into 2 point 5m 2 point 0 into 2 point 5m 2 point 0 into 3 point 0m 2 point 0 into 3 point 0m ninth recommendation for type of foundation of rcc frame structure tenth rl of the ground level oblique foundation level with ref to a bm should invariably be mentioned in the soil investigation report eleventh recommendation as regards possibilities of liquefaction of soil in case of saturated or partially saturated loose uncomplicated sandy soil twelve swelling index and swelling pressure in respect of black cotton soil and its depth layer thirteen chemical analysis for ph electrometrically comma sulphate and chloride contents
Tender For corrigendum : supply of soil investigation - atterbergs limits is 2720 part 5 , wet dry density sample minium two sample , soil particle size distribution using sieve analysis hydrometer analysis , tri-axial shear test c determination , shrinkage test , consolidation test. , specific gravity test. , crushing strength of rocks sample. , permeability test. , chemical analysis of ground water sample minium two sample , free soil index , nature moisture content.
Tender For iso propyl alcohol, laboratory grade (c3h8o : mw : 60.10) to is:2631 in 2.5 litre conta iners.guarantee analysis : assay : nlt 99.0% , weight per ml at 20 deg.c : 0.784-0.786g, distillation range : 81 - 83 deg.c maximum limit of impurities : 1) non-volatile matter : 0.01 %, 2) acidity (c2h5 c00h) : 0.005 %, 3) alkalinity : 0.001 %, 4) aldehydes & ketones : 0.1 %, 5) heavy metal (as pb) : 0.00 2 %, 6) water (by kf) : 0.2 %, 7) readily carbonisable substances : passes test. approved brands : ra nkem of m/s.ranbaxy (or) qualigens of m/s.glaxo. supply shall be made in batches of 75 litres every month. [ warranty period: 30 months after the date of delivery ]