Tender For repair to water supply distribution network including disinfection of water supply at various pump house and repair to various submersible pump, booster electric control system at af station chandigarh under ge (af) chandigarh
Tender For repair / maint of split acs 2/1.5 ton , windows acs 2 / 1.5 ton , voltage stablizers and connected items installed at command hospital (wc) and other various location in aor of age e/m ch - servicing of split type ac of capacity 2/ 1.5 tr after disconnecting all incoming and outgoing electric connection, water drain pipe line connection etc. and wash with approved chemical mixed water with the pressure pump, after servicing cleaned all the disturbed area and reassembling the water/electric connection and testing for entire satisfaction of engr-in-charge., all as per item no. 1 here-in-above but window type ac 2/1.5 tr capacity., supplying and charging of refrigerant gas r-22 only after vacuuming dehydration, leak testing of the system as per standard practice testing for proper cooling effects and satisfactory performance complete all as specified and as directed by engr-in-charge for room split/window type ac of capacity 2/1.5 tr., all as per item no: 3 above but gas r-32, all as per item no: 3 above but gas r-410a., all as per item no: 3 above but gas r-134a., taking out defective capacitor of capacity 50+6 mfd after disconnecting all incoming and outgoing electric connection including supply & fix new capacitor on same place and testing complete all as specified and as directed by engr-in-charge, all as per item no:7 here in above but of capacity 45+4 mfd ., all as per item no:7 here in above but of capacity 45 mfd ., all as per item no: 7 here in above but of capacity 6 mfd ., all as per item no: 7 here in above but of capacity 4 mfd ., supply & fixing as in replacement copper pipe 1/2" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 1/4" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 5/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 3/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply and fixing of insulation foam for copper pipe of size 1/2" after removing old one., supply and fixing of insulation foam for copper pipe of size 1/4" after removing old one., supply and fixing of insulation foam for copper pipe of size 5/8" after removing old one., supply and fixing of insulation foam for copper pipe of size 3/8" after removing old one., supply and fixing as in replacement of pvc flexible pipe 15 mm dia including any fittings as required complete inclusive of any type of leakage testing., all as per item no: 20 above but pipe of 20 mm dia., supply and fixing as in replacement of pvc water drain pipe 25 mm dia complete inclusive all fittings and any type of leakage testing., material and labour for sub main wiring with 2 x 2.5 sqmm +1 x 2.5 sqmm single core flame retardant pvc insulated unsheathed cable with stranded copper conductor drawn in and including heavy grade frlsh pvc concealed conduit isi marked with all accessories on walls and making good the disturbed surfaces including all conduits fittings, clamps guittes etc for earth dbs and boxes with proper thimbles all as directed by engr-in-charge. note :02 run of 2.5 sqmm , 01 run of 2.5 sqmm cable and 01 run of conduit shall be measured as one unit and paid accordingly., all as per item no: 23 here in above but of size 2x 4 sqmm +1x 4 sqmm., m&l cutting chases, pinning in stone concrete block or slab walls & making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring ,etc., and making good, cutting exc. 10 cm girth., supply and fix as in replacement of rigid non-metallic pvc conduit of size 20
Tender For 1. repair maintenance of of electrical installation fans electric sub station water supply pump street light split hot and cold inverter based ac cctv lift at r and t wing production wing and repair maintenance of of 2x750 kva sub stain at dpt 2. repair maintenance of ac plants for animal house and central drugs laboratory at cri kasauli hp sh servicing of ht /lt sub staion equipments dehydration of transformer oil etc.
Tender For गंदे पानी की निकासी हेतु विधुत मोटर एंड मड पंप जनेरटर सबमर्सिबल मोटर पंप सर्विस एंड रिपेयर - electric motor and mud pump generator for dirty water disposal, submersible motor pump service and repair.
Tender For corrigendum : repair and comprehensive maintenance of swimming pool plant and equipments fire fighting system at af stn nal under ge (af) nal - comprehensive annual maintenance of swimming pool comprises of the following equipments complete all as specified and directed.(a) pumping sets of capacity 3.5 hp - 05 nos (01 as standby) (b) pressure filter of filtering capacity 50 cum/hr - 04 nos (01 as standby)(c) dosing pump - 02 nos (one for chlorination and one for soda ash)(d) electrical panel board consisting of starters of suitable rating complete.note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit swimming pool once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of swimming pool.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account. (iii) cleaning all swimming pool building inside, plant room, equipments including surrounding area of the buildings. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of 3.5hp / 3.26 kw capacity and all other connected items., comprehensive annual maintenance of fire fighting system in sekhon hall , new tech flight, sre and new atc of the following equipments complete all as specified and directed.(a) main fire pump with centrifugal motor of existing capacity- 04 nos (b) jockey fire pump with electric motor of existing capacity - 04 nos (c) makeup fire pump- 04 nos(d) dg fire pump with engine - 04 nos note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit fire fighting installation in sekhon hall , new tech flight and new atc once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of installation.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account.(iii) cleaning all fire fighting installation buildings (sekhon hall , new tech flight and new atc) inside, plant room,equipments including surrounding area of the building. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of all existing capacity and all other connected items., s&f in repair pressure pump limit switch of capacity 1psi to 4 psi and 230 volt as per existing make and model fixed on pressure booster line complete all as specified and directed., supply, installation, testing and commissioning in repair of detectors complying with and type certified to en-45 addressable type multi sensor detector with heat and smoke combination with base with self built intelligence as per is:11360 (for annexes) complete all as specified and directed., supply, installation, testing and commissioning in repair of addressable manual call point / pill station resettable type with base complete all as specified and directed, supply, installation, testing and commissioning in repair of fire alarm sounder/siren electronic type horizontal single stage continuous type normal operation for atleast 50 minutes with sound level 65 db to 120 db measured at 1.5 mtr with sound output variation +5 db 500 mtr complete all as specified and directed, supply and fixing in repair addressable monitor module for activating the sirens complete all as specified and directed, taking out old unserviceable hose box by cutting and welding and s&f hose box made of 18 gauge ms sheet 800mmx 600 mm x 250 mm with double door with 4 mm thick glasses and door frame made of 16 gauge ms sheet for keeping 2 nos hose pipe of length 15 mtr each branch pipe nozzle coupling etc and painted fire red out side and brilliant white inside yard complete all as specified and dire
Tender For annual repair and maintenance of buildings in bm-i division during 2026-27. sh- annual maintenance of pump and electric accessories of pump room underthe jurisdiction of rohini service centre
Tender For repair maintenance of of electrical installation, fans electric sub station, water supply pump, street light, split hot and cold inverter based ac, cctv, lift at r and t wing, production wing and repair maintenance of of 2 x 750 kva, sub station at dpt for year 2026-27. (sh- improvement of electrical supply system)subwork/packages:rmo of electrical installation, fans electric sub station, water supply pump, street light, split hot and cold inverter based ac, cctv, lift at r and t wing, production wing and repair maintenance of of 2 x 750 kva, sub station at dpt for year 2026-27. (sh- improvement of electrical supply system).