Tender For corrigendum : servicing and minor repairing of dieselenginealternatorsets ic providing battery and other associated work at leased out hub sites under ba prayagraj up.
Tender For provision towards purchase of necessary items (equipments) to government hospital in mydukur municipality. - supply, transportation and installation of desktop with fully loaded software as desired, with the following configuration. 1. processor: intel® core? i7-12th generation or higher version processor with intel® hd graphics 770 (2.9 ghz base frequency, up to 4.9 ghz with intel® turbo boost technology, 25 mb l3 cache, 12 cores 20 threads) intel q670 chipset 2. memory: 8 gb ddr4-3200 mhz sdram (1 x 8 gb) memory slots 2 dimm 3. hard drive 512gb ssd (hard drive 2 nd 1 tb 7200 sata hdd ) 4. 1 audio line in; 1 audio line out; 1 hdmi; 1 rj-45; 1 vga; 4 usb 3.0; 4 usb 2.0 5. operating systems: windows 11 pro professional 64 bit with product key license. 6. communications (intel wi-fi & blue tooth) 7. preloaded with latest version of antivirus symantec/ mcafee / nod32 / e-trust / avast internet security / kaspersky / quick heal / escan / msecure with following features: antivirus, antispyware, intrusion prevention browser protection with single management console with 3 year subscription with support updates and patches. 8. accessories: with required connecting cables and driver media should be supplied. 9. warranty: 3 year standard on-site comprehensive hardware warranty (including o.s support, spares- parts/service/labour/on-site) makes: hp prodesk or its equivalent in dell, supply, transportation and installation of all-in-one (print, copy, scan) with duplex, auto document feeder features: -print resolution 600 x 600dpi -print speed (a4) 27ppm -auto duplex printing standard -available paper size for auto duplex print a4, letter, legal (*1), indian legal, fulllscape -copy copy speed (a4) 27ppm maximum number of copies up to 999 copies scan type colour contact image sensor scan resolution optical up to 600 x 600dpi pull scan yes, usb and network makes: makes: canon imageclass mf244dw /hp/brother dcpb7535dw or its equivalen, supply installation testing and commissioning of dg set complete with 1500 rpm dieselengine of suitable bhp & ac brush less spdp alternator mounted on a common base frame & coupled through a flexible coupling or close coupled.alternator: it shall be self-regulated, self-excited and confirms to is: 13364/1992 or latest version with regulation of +5% from no load to full load, ip23, with standard alternator protection (over voltage, over speed& under voltage).dieselengine: it shall have residential silencer, up to 10 m exhaust piping, electronic / mechanical governor, manual & electric start, batteries, fuel tank & piping, control panel (16 g) with spn(for 5 kva)/tpn mccb of required rating (25/36/50 ka) with plc based engine controller supplied by oem, ammeter, voltmeter, frequency meter or multi-function meter, energy meter & hour meter, engine instruments panel, avm and automatic voltage regulator. the dieselengine shall be capable of providing 10% overload for 1 hr for every 11 hrs of continuous running at full load. the dg set shall be supplied with initial filling of fuel, lube oil, coolant oil as per oem specifications and shall be tested at site.acoustic enclosure: weatherproof, powder coated acoustic enclosure for dg set for sound attenuation fabricated from 1.6 mm crca sheet steel (structure) with side wall fabricated from 1.6 mm crca sheet and filled with foam as per cpcb norms latest amendments & is 8183. the doors are fabricated from 1.6 mm crca sheet packed with acoustic material, floor of ms chequered plate 5.0 mm thick, all doors/ opening are sealed with neoprene/ epdn gaskets.the dg set shall be maintained for two years after commissioning by the supplier including regular servicing,cost of consumables etc complete as specified by the oem along with warranty for two years.the enclosure has built in fuel tank, residential silencer (isolated from main dg chamber) with protection and tripping of dg set against temperature of more than 50 °c. all controls for opera
Tender For : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of spares for diese
Tender For servicing and minor repairing of dieselenginealternatorsets ic providing battery and other associated work at various bts hub sites under ba sultanpur up.
Tender For corrigendum : supply of obs and b and d spares of dieselalternator of nt buland : - fuel filter ctg , lub oil filter , for kfa , v belt , coolant , rocker cover joint metalic , sea water pump , wp assembly , thermostat element , turbo charger , magnetic pickup , lub oil pressure switch , set of copper washer , alternator , hose , injector , set of joints , set of o ring , water pump belt 3 , water pump assembly , combined leak of pipe assembly , starter , supply hose , thermostat bypass hose , joint for thermostat cover , rubber hose , locating bolt , lub oil supply hose , hose straight , worm drive hose clip , fuel pipe , ss joint for exhaust manifold , speed control , leak off assembly , ss hose clip , ss hose clip sf , banjo bolt , special benjo bolt , rocker cover gasket , f002 g1b 704 chargine alternator , pr transmitter , heat exchanger , valve tappet , wire snap ring , valve collect 3 groove , vr toe , valve spring , engine controller 12v dc , starter 24v , starter 12v
Tender For corrigendum : servicing of 1no 250kva dieselenginealternatorset no-1 (make- kirloskar) and 1no 250 kva dieselenginealternator (make-greaves) at telephone exchange keonjhar and 100kva dea set (make -cummins) at te joda under keonjhar ssa(sw- servicing of 1n
Tender For corrigendum : servicing of 1no 250kva dieselenginealternatorset no-1 (make-greaves) and 1no 160 kva dieselenginealternator (make- greaves) at telephone exchange nalconagar under dhenkanal ssa
Tender For corrigendum : servicing of 1no 250kva dieselenginealternatorset no-1 (make- greaves) and 1no 100 kva dieselenginealternator (make- kirloskar) at telephone bhawan dhenkanal under dhenkanal ssa
Tender For the detail of works includes:a. the tenderer shall carryout the following works during annual maintenance contract period along with the servicing of the diesel generator set.1. general checkup & preventive maintenance and to fill up preventive checkup schedule as follows:a) check lube oil level and conditioning of lube oil, top up/refill if required.b) the oil filters shall be replaced whenever oil is changed.c) the air filters shall be cleaned periodically with compressed air, check batteries and top up the distilled water if required.d) check functioning of changing alternator.e) engine safety viz. high water temperature gauge, oil temperature gauge and high speed gauge shall be checked for their functions and repaired/replaced if required.f) coolant level and conditioning of coolant shall be checked and refilled if required.g) check fan and alternator drive belts and tightened if required.h) the governor shall be checked and tuned for proper functioning.i) check for leaks if any and shall be rectified.j) check reports shall be submitted every month/every breakdown calls.2. checking and servicing of engine for smooth running, its unusual sound and color of smoke and exhaust and set it right in case of deviations.3. checking and repairing and leakage of fuel, lubricating oil and coolant.4. cleaning and changing of air filters as per requirement.5. setting of valves tappets whenever required.6. checking and repairing of accessories drive, turbo charger and crankshaft endplay whenever required.7. checking of alignment of engine & alternator as per requirement.8. checking of throttle control and its setting.9. checking of instrument panel including replacement as and when required.10. checking of rotating diodes assembly in brushless alternator including replacement as and when required.11. checking of wiring system and repairing/replacement as and when required.12. repair and maintenance of relays including contractors in control panel.13. checking of battery terminal and de-sulphating.14. diagnosis of faults in engine and alternator and its rectification.15. breakdown calls to be attended on priority within 6 hrs.16. providing spare avrs, self-starter and accessories, free of charge, if the repair/overhaul/replacement is expected to be taken in more than two days.17. checking/repair/adjustment/replacement/servicing shall be carried under annual maintenance contract except cost of component/parts to be replaced due to wear & tear.18. the firm should undertake to arrange genuine spares of the dieselengine, alternator and amf panel as and when required within two working days.19. the tenderer’s service engineer shall visit the site for attending the generator sets not less than twelve times during the contract period (minimum once in a month) and shall inspect the generator set thoroughly. each visit shall take place during 1st week of each month.20. the tenderer’s service engineer shall visit once in two month for checking of electrical side viz. alternator, amf control panel, if any.21. the engine shall be run on no load or at available load, and should be checked for any leakage and abnormal noise. if any such abnormality noticed shall be diagnosed and remedial action shall be taken.22. standard check list:a) replace minor parts (i.e hoses and filters etc) sub-assemblies as and when required.b) service engineers during the visit will report on the performance or any other abnormality and inform parts requirement. he shall also submit the report on work done and recommendations as well as spare parts required.c) attend emergency call on priority (usually same day). however, if the engineer is required or any particular date and time, it would be the responsibility of the customer to intimate the contractor in advance.d) major overhauling/ top overhauling / pt pump & injector calibration /replacement of major parts/ rewinding of alternator or repairs or breakdown of the diesel generator set are to be charge
Tender For supply, installation, testing and commissioning of 200 kva dieselenginealternatorset at tebuilding vemana, ananapur sh providing c.c. foundation, earthing andother works