Web Analytics Made Easy - StatCounter

Diesel Engine Alternator Tenders

Get complete information related to latest Diesel Engine Alternator Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Diesel Engine Alternator Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Diesel Engine Alternator Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government And Public Sector

CTN :45189164 Due date: 23 May, 202623 May, 2026 NA
Tender For corrigendum : servicing and minor repairing of diesel engine alternator sets ic providing battery and other associated work at leased out hub sites under ba prayagraj up.

CTN :45048307 Due date: 08 Jun, 202608 Jun, 2026 NA
Tender For : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of spares for diese

Central Government And Public Sector

CTN :45182740 Due date: 19 May, 202619 May, 2026 NA
Tender For servicing and minor repairing of diesel engine alternator sets ic providing battery and other associated work at various bts hub sites under ba sultanpur up.

Central Government/Public Sector

CTN :45024121 Due date: 20 May, 202620 May, 2026 NA
Tender For rajkot division schedule maintenance contract of cummins make diesel engine, alternator and accessories installed in lhb power cars of rajkot division for 02 years

Central Government And Public Sector

CTN :44615241 Due date: 24 Apr, 202624 Apr, 2026 1.08 Lacs
Tender For corrigendum : servicing of 1no 250kva diesel engine alternator set no-1 (make- kirloskar) and 1no 250 kva diesel engine alternator (make-greaves) at telephone exchange keonjhar and 100kva dea set (make -cummins) at te joda under keonjhar ssa(sw- servicing of 1n

Central Government And Public Sector

CTN :44615243 Due date: 22 Apr, 202622 Apr, 2026 73.1 Thousand
Tender For corrigendum : servicing of 1no 250kva diesel engine alternator set no-1 (make-greaves) and 1no 160 kva diesel engine alternator (make- greaves) at telephone exchange nalconagar under dhenkanal ssa

Central Government And Public Sector

CTN :44615237 Due date: 22 Apr, 202622 Apr, 2026 65.0 Thousand
Tender For corrigendum : servicing of 1no 250kva diesel engine alternator set no-1 (make- greaves) and 1no 100 kva diesel engine alternator (make- kirloskar) at telephone bhawan dhenkanal under dhenkanal ssa

State Government

CTN :44798192 Due date: 28 Apr, 202628 Apr, 2026 1.97 Lacs
Tender For the detail of works includes:a. the tenderer shall carryout the following works during annual maintenance contract period along with the servicing of the diesel generator set.1. general checkup & preventive maintenance and to fill up preventive checkup schedule as follows:a) check lube oil level and conditioning of lube oil, top up/refill if required.b) the oil filters shall be replaced whenever oil is changed.c) the air filters shall be cleaned periodically with compressed air, check batteries and top up the distilled water if required.d) check functioning of changing alternator.e) engine safety viz. high water temperature gauge, oil temperature gauge and high speed gauge shall be checked for their functions and repaired/replaced if required.f) coolant level and conditioning of coolant shall be checked and refilled if required.g) check fan and alternator drive belts and tightened if required.h) the governor shall be checked and tuned for proper functioning.i) check for leaks if any and shall be rectified.j) check reports shall be submitted every month/every breakdown calls.2. checking and servicing of engine for smooth running, its unusual sound and color of smoke and exhaust and set it right in case of deviations.3. checking and repairing and leakage of fuel, lubricating oil and coolant.4. cleaning and changing of air filters as per requirement.5. setting of valves tappets whenever required.6. checking and repairing of accessories drive, turbo charger and crankshaft endplay whenever required.7. checking of alignment of engine & alternator as per requirement.8. checking of throttle control and its setting.9. checking of instrument panel including replacement as and when required.10. checking of rotating diodes assembly in brushless alternator including replacement as and when required.11. checking of wiring system and repairing/replacement as and when required.12. repair and maintenance of relays including contractors in control panel.13. checking of battery terminal and de-sulphating.14. diagnosis of faults in engine and alternator and its rectification.15. breakdown calls to be attended on priority within 6 hrs.16. providing spare avrs, self-starter and accessories, free of charge, if the repair/overhaul/replacement is expected to be taken in more than two days.17. checking/repair/adjustment/replacement/servicing shall be carried under annual maintenance contract except cost of component/parts to be replaced due to wear & tear.18. the firm should undertake to arrange genuine spares of the diesel engine, alternator and amf panel as and when required within two working days.19. the tenderer’s service engineer shall visit the site for attending the generator sets not less than twelve times during the contract period (minimum once in a month) and shall inspect the generator set thoroughly. each visit shall take place during 1st week of each month.20. the tenderer’s service engineer shall visit once in two month for checking of electrical side viz. alternator, amf control panel, if any.21. the engine shall be run on no load or at available load, and should be checked for any leakage and abnormal noise. if any such abnormality noticed shall be diagnosed and remedial action shall be taken.22. standard check list:a) replace minor parts (i.e hoses and filters etc) sub-assemblies as and when required.b) service engineers during the visit will report on the performance or any other abnormality and inform parts requirement. he shall also submit the report on work done and recommendations as well as spare parts required.c) attend emergency call on priority (usually same day). however, if the engineer is required or any particular date and time, it would be the responsibility of the customer to intimate the contractor in advance.d) major overhauling/ top overhauling / pt pump & injector calibration /replacement of major parts/ rewinding of alternator or repairs or breakdown of the diesel generator set are to be charge

Central Government And Public Sector

CTN :44736890 Due date: 10 Apr, 202610 Apr, 2026 4.94 Lacs
Tender For supply, installation, testing and commissioning of 200 kva diesel engine alternator set at tebuilding vemana, ananapur sh providing c.c. foundation, earthing andother works

Central Government And Public Sector

CTN :44717954 Due date: 10 Apr, 202610 Apr, 2026 4.19 Lacs
Tender For providing dg bed earthing power cabling works for 30 kva dg sets at te bts sites jorabat, zoo road, hatigarh, gorchuk in kamrup ba - sitc of 10x30 kva diesel engine alternator sets at different important hub sites under kamrup ba.( sh:- providing dg set bed, earthing , power cable for 30 kva dg set and equipment earthing etc . at te/bts jorabat, zoo road, hatigarh, gorchuk.)
 Loading, Please wait...

Connect us via What's Up