Get complete information related to latest Diesel Engines Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Diesel Engines Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Diesel Engines Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45473382 Due date: 03 Aug, 202603 Aug, 2026 NA
Tender For corrigendum : supply of engine oil sae 15w 40 api-ci-4 plus grade lubricant oil. brand: valvoline premium blue 7800 plus of m/s. valvoline cummins (p) ltd., or equivalent brand from m/s. greaves cotton ltd., m/s. koel , m/s. hpcl, m/s. bpcl or m/s. iocl. suitable for cpcb-i and cpcb-ii compliant diesel engines. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variationpermitted: max 8 lacs ] ]

Central Government/Public Sector

CTN :45730573 Due date: 22 Jul, 202622 Jul, 2026 NA
Tender For four yearly d-check schedule (d-check) of cummins make diesel engines model no. nta-14-r & diesel engines model of diesel generator set no. qsb 5.9g of hs-spart/kalyan at parel workshop.

State Government

CTN :45744871 Due date: 09 Jul, 202609 Jul, 2026 NA
Tender For hiring of maxi cab (non- air condition, bharat stage iii on or after 01/05/2008 with diesel / lpg/cng engine) in perfect good running condition of performing a very long journey and should be covered without any trouble on daily hire basis for official use for the office of the assistant engineer, jangipur sub division, p.h.e dte. n.b: 1. vehicle shall not be used other than departmental works and must be placed in every month otherwise deduction to be made pro-rate basic. 2. fuel @ 1 ltr per 10 km for maxi cab and mobil oil @ 5 ltr per 2500 km will be allowed. 3. all other rules & regulation have to be maintained according to latest gazette and govt. order. 3564-wt/3m-81/98 dated-24/11/2008.

Central Government/Public Sector

CTN :45737057 Due date: 17 Jul, 202617 Jul, 2026 NA
Tender For diesel exhaust fluid (def) solution dgblue def for cpcb iv+ (aqueous urea solution 32%) for cpcb-iv compliant 500 kva diesel engines of power car with cummins part no. ax1018395 confirming to rdso letter no. el/0.6.2/pc main dt-03/02/25 for cummins make engine.note:sample may got approved before bulk supply. [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45743718 Due date: 13 Jul, 202613 Jul, 2026 NA
Tender For 250 kva diesel generator set with amf control panel, power generator installation configuration as defined in cpwd general specifications for electrical works-part-vii (dg set) -fixed (power generators are permanently installed), nominal rated capacity (kva)-250, rated engine power(kwa)- 110% of the required powered at stp (standard temperature pressure) i.e equal ? to (nominal rated capacity (kva) of power generator any auxiliary power consumption by the power generator) x power factor (0.8)/alternator efficiency , type of governor-electronic, rated rpm of engine(rpm)-1500, fuel-high speed diesel (hsd),control panel-amf control panel , installation- with installation-inclusive in the scope of supply, warranty on complete power generator/dg set-24 months , no . of phase- 3, number of cylinders-6,starting voltage-24, type of alternator-brushless, fuel tank capacity- 600 liter, battery capacity(ah)-100,no. of battery2, testing report available for (test/approval)-type approval certificate for the specified rating of the power generator from any of the designated agency authorized by cpcb,cop certificate for engine type test report and endurance test report for engine as per is :10001 latest/ls:10002 latest,type test report for alternator as per is : 13364 (part-1) latest/is: 13364 (part-2) latest to prove conformity to the specification , make-cummins power, greaves, kirloskar or similar. [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45546255 Due date: 13 Jul, 202613 Jul, 2026 NA
Tender For corrigendum : 250 kva diesel generator set with amf control panel, power generator installation configuration as defined in cpwd general specifications for electrical works-part-vii (dg set) -fixed (power generators are permanently installed), nominal rated capacity (kva)-250, rated engine power(kwa)- 110% of the required powered at stp (standard temperature pressure) i.e equal ? to (nominal rated capacity (kva) of power generator any auxiliary power consumption by the power generator) x power factor (0.8)/alternator efficiency , type of governor-electronic, rated rpm of engine(rpm)-1500, fuel-high speed diesel (hsd),control panel-amf control panel , installation- with installation-inclusive in the scope of supply, warranty on complete power generator/dg set-24 months , no . of phase- 3, number of cylinders-6,starting voltage-24, type of alternator-brushless, fuel tank capacity- 600 liter, battery capacity(ah)-100,no. of battery2, testing report available for (test/approval)-type approval certificate for the specified rating of the power generator from any of the designated agency authorized by cpcb,cop certificate for engine type test report and endurance test report for engine as per is :10001 latest/ls:10002 latest,type test report for alternator as per is : 13364 (part-1) latest/is: 13364 (part-2) latest to prove conformity to the specification , make-cummins power, greaves, kirloskar or similar. [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45726505 Due date: 20 Jul, 202620 Jul, 2026 45.00 Lacs
Tender For repair/maintenance of diesel generator set with central panel and other connected items at zone 5 and 1(a,b,c) zone 1, 3 (a and b), zone 2 and zone 4 under ge (s) tezpur - maint and servicing of dg set 320-400 kva conopy type with amf panel (if installed ), through authorise service agency of oem , including replacment of defective/wornout parts with new spares such as filters, gaskets, v belts, engine oil, coolant for radiator rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner , including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water and cleaning of pol tank and radiator etc complete all as specified and directed.note:- 1. spares required for above maint will be measured and paid separately under relevent items of schedule. 2. all breakdown calls should be attended., all as per item no-1 above but for dg set of capacity 180-250 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 125-160 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 40-100 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 10-35 kva complete all as specified and directed, supply only fuel filter for 300-400 kva dg set, complete all as specified and directed, supply only fuel filter for 125-250 kva dg set,complete all as specified and directed complete all as specified and directed, supply only fuel filter for 10-100 kva dg set,complete all as specified and directed, supply only lub oil filter for 300-400 kva dg set,complete all as specified and directed, supply only lub oil filter for 125-250 kva dg set,complete all as specified and directed, supply only lub oil filter for 10-100 kva dg set,complete all as specified and directed, supply only air cleaner filter ( inner and outer ) for 300-400 kva dg set, complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 125-250 kva dg set,complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 10-100 kva dg set,complete all as specified and directed, supply only bypass filter for 300-400 kva dg set, complete all as specified and directed, supply only bypass filter for 125-250 kva dg set,complete all as specified and directed, supply only bypass filter for 10-100 kva dg set,complete all as specified and directed, supply only v belt for 300-400 kva dg set, complete all as specified and directed, supply only v belt for 125-250 kva dg set, complete all as specified and directed, supply only v belt for 10-100 kva dg set, complete all as specified and directed, supply only coolant for radiators complete all as specified and directed., supply only engine oil multi grade 15w40 complete all as specified and directed., s & f in repair display control panel ( base card) for 10 to 100 kva dg set complete all as specified and directed ., s & f in repair display control panel (base card) for 125 to 250 kva dg set complete all as specified and directed., s & f in repair display control panel (base card) for 300 to 400 kva dg set complete all as specified and directed., s & f in repair fuel actuator with o ring for 300 to 400 kva dg set complete all as specified and directed., s & f in repair key switch for 10 to 400kva dg set complete all as specified and directed., s & f in repair coolant temperature sensor (coolent control safety) for 10 to 400kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 10 to 100 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 125 to 250 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 300 to 400kva dg set complete all as specified and directed., s & f in rep

Central Government / Public Sector

CTN :45730889 Due date: 13 Jul, 202613 Jul, 2026 NA
Tender For b check kit for 500 kva d.g. set of eog power car,engine model ,no. cpcb iv .consisting of thease items , (1) filter ,fuel part no -ax1017055 - 01.no, (2) foil, sealed test stripscc2602b , part no. 3403800- 01.no. (3) cartridge fuel filter,part no-5627726 - 01.no. (4) element luboil filter , part no - ax1017056 - 01.no. (5 ) filter def , part no, a059z389 (6) inhibitor corrosion 10 litercap -part no, 4926654 - 01.no.(7) lube oil ck4 , grade-15w40 - part no , 508305 - 10 liter can 01.no. (8) belt , v ribbed ,part no , 5663603 - 01.no. (9 ) filter ,diesel exhaust fluid , part no, a035d361-01.no. note1:01.set consists of above 09-items. note2 : make- cummins, engine compliant - cpcb iv . acceted make:cummins only. note3: firm should supply part no. 508305, lube oil ck4, grade15w40 with a 10-liter capacity can, not a 55- liter capacityfor this part number. [ warranty period: 30 months after the date of delivery ] ]

Central Government And Public Sector

CTN :45617729 Due date: 03 Jul, 202603 Jul, 2026 5.66 Lacs
Tender For corrigendum : providing of repair and maintenance of dg set under daltonganj - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva

Central Government And Public Sector

CTN :45615691 Due date: 02 Jul, 202602 Jul, 2026 5.65 Lacs
Tender For corrigendum : supply of repair and preventive maintenance of dg set ranchi oa - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva //bid details 2 / 35