Web Analytics Made Easy - StatCounter

Diesel Generator Pump Tenders

Get complete information related to latest Diesel Generator Pump Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Diesel Generator Pump Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Diesel Generator Pump Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45174759 Due date: 19 May, 202619 May, 2026 NA
Tender For auction sale of others - released material of rcd consisting, {(1) oil storage tank cap - 200 kl, 01 no, (2) oil storage tank cap -70 kl, 03 nos, (3) oil storage tank cap-225 kl, 01 no, (4) 4 inch dia ms pipe 250 mtr, (5) 3 inch dia m.s pipe- 290 mtr, (6) 2 inch dia m.s pipe- 02 mtr, (7) 1 inch dia m.s pipe 15 mtr, (8) 4 inch valve- 08 nos, (9) 3 inch valve- 17 nos, (10) 2 inch valve- 10 nos, (11) 3 inch non return valve 01 no, (12) 4 inch steiner 01 no, (13) 3 inch steiner 02 nos, (14) fuel filling machine 01 no, (15) manual hutter 02 nos, (16) 10 hp electric motor pump 02 nos, (17) 10 hp diesel generator pump 01 no in installed condition}, total qty- 230.015 mt, location- rcd (fuel cell) locomotive care centre ratlam. mode of delivery by actual weighment basis and on as is where is basis, custodian- sse-dl-rtm , fdp- 80 days. note- (1) tank and related items to be dismantle by the firm with proper safety and equipments. (3) cutting permitted.

Central Government/Public Sector

CTN :44964644 Due date: 04 May, 202604 May, 2026 NA
Tender For auction sale of others - released material of rcd consisting, {(1) oil storage tank cap - 200 kl, 01 no, (2) oil storage tank cap -70 kl, 03 nos, (3) oil storage tank cap-225 kl, 01 no, (4) 4 inch dia ms pipe 250 mtr, (5) 3 inch dia m.s pipe- 290 mtr, (6) 2 inch dia m.s pipe- 02 mtr, (7) 1 inch dia m.s pipe 15 mtr, (8) 4 inch valve- 08 nos, (9) 3 inch valve- 17 nos, (10) 2 inch valve- 10 nos, (11) 3 inch non return valve 01 no, (12) 4 inch steiner 01 no, (13) 3 inch steiner 02 nos, (14) fuel filling machine 01 no, (15) manual hutter 02 nos, (16) 10 hp diesel electric motor pump 02 nos, (17) 10 hp diesel generator pump 01 no in installed condition}, total qty- 230.015 mt, location- rcd (fuel cell) locomotive care centre ratlam. mode of delivery by actual weighment basis and on as is where is basis, custodian- sse-dl-rtm , fdp- 80 days. note- (1) tank and related items to be dismantle by the firm with proper safety and equipments. (3) cutting permitted, (3) the eligible bidder shall prepare and submit the detailed dismantling scheme including methodology, safety precautions, sequence of dismantling, equipment to be used and traffic/safety arrangements to sr. dme/lcc/rtm through sr. dmm/rtm.

CTN :44891328 Due date: 30 Apr, 202630 Apr, 2026 NA
Tender For miscellaneous works in thermal-2 - miscellaneous works in thermal-2, the work shall be carried out on a manday basis and includes collection, segregation, and shifting of metallic and non-metallic waste materials from the thermal-2 building premises. the activities cover handling of rusted metallic items, structural scrap, insulation materials, oil sludge/oil slick, mud, debris, and other miscellaneous scrap lying at various locations such as the ground floor near boiler area, pipe rack area, tg floor area, cooling tower area, and other surrounding premises. the work also includes bringing down waste materials from different floors of boiler units 1, 2, and 3 to ground level and consolidating them at a designated location. all manpower, tools, tackles, and equipment shall be provided by the contractor. payment shall be made based on actual mandays engaged and certified by the engineer-in-charge., the work shall be executed on a manday basis and includes loading and unloading of segregated metallic and non-metallic scrap/waste materials within the fact ud / petro plant premises as directed by the engineer-in-charge. all required manpower, tools, tackles, and handling equipment including concrete lump breakers shall be arranged by the contractor. payment shall be made based on actual mandays engaged and certified by the engineer-in-charge., transportation of scrap and waste materials loaded under sl. no. 2 from cpp - pd premises to the designated scrap yard, waste dumping area, or any other location within the fact ud / petro plant premises, as directed by the engineer-in-charge. the contractor shall provide a suitable truck having carrying capacity up to 2 tonnes for the purpose.the rate per trip shall be inclusive of all charges such as vehicle hire, driver wages, fuel, and any other incidental expenses.copies of the relevant scrap dispatch advice and weighbridge report shall be submitted by the contractor for each lot of material transported. the quantity indicated is tentative and payment shall be made based on actual number of trips certified by the engineer-in-charge., the work shall be performed on a manday basis and includes moving and rearranging used materials and equipment parts such as valves, pumps, flanges, motors, radiators, drums, welding sets, structural items, roof sheets, and other related materials stacked at various locations including cpp building north and south entrance areas, boiler feed pump area, tg floor area, and other specified locations, as instructed by the engineer-in-charge. required cleaning materials, rigging materials, tools, tackles, and manpower shall be arranged by the contractor. the eot crane at the tg floor may be used free of cost, subject to availability. loading and unloading for shifting within the petro plant premises shall be in the contractor s scope. payment shall be made based on actual mandays engaged and certified by the engineer-in-charge., the work shall be carried out on a manday basis and includes removal of vegetation from the outer side walls and top platforms of cooling tower cells, removal of vegetation from the side walls and floor of the cooling tower pond, and removal of accumulated mud, slurry, and other unwanted materials within the cpp cooling tower area. all manpower, tools, tackles, and equipment required for execution shall be arranged by the contractor. cleaning of all four cooling tower cells shall be treated as a single activity., the work shall be executed on a manday basis and includes thorough cleaning of the furnace oil (fo) pump house area. furnace oil spillage on floors, including areas beneath oil heaters, around pumps, condensate drains, and adjoining areas, shall be removed by spreading sawdust and collecting the oil-soaked sawdust for proper disposal as instructed by the engineer-in-charge. sawdust, cotton waste, manpower, tools, and all other materials required for complete execution of the work shall be arranged by the contractor. payment shall
 Loading, Please wait...

Connect us via What's Up