Tender For supply of one highly skilled support staff , two skilled support staff , three un skilled support staff , cat 6 utp data cable , 3 core 1 point 5 sqmm power cable , 6 core single mode armoured ofc outdoor cable , 2 inches casing and capping , 1 inches casing and capping , 25mm pvc conduit pipe , rj 11 connector , 10 pair pouyet type disconnection krone module , 2 pair pvc telephone cable 0 point 5mm , 5 pair pvc telephone cable 0 point 5mm , 10 pair pvc telephone cable 0 point 5mm , 20 pair pvc telephone cable 0 point 5mm , 02 pair field telephone cable , 10 pair armoured jelly filled telephone cable 05mm , 50 pair armoured jelly filled telephone cable 05mm , 100 pair armoured jelly filled telephone cable 05mm , cat 6 dual face plate with i o box set with rj45 keystone jack , single port telephone rosette box , tsf joint kit for 50 pair telephone cable , tsf joint kit for 100 pair telephone cable , 200 pair krone module , 100 pair krone module , 50 pair krone module , 20 pair krone module , line cord of two meters , spiral cords for telephone handset , telephone jumper wire 0 point 5mm , one plus one telephone instrument with caller id , telephone instrument with caller id , integrated protection module against lightning overvoltage over current , sc lc sm duplex 1 point 5 metre ofc , 12 port liu , telephone stand , supply of pouyet ocb krone tool , supply of pouyet ocb test cord , telephone line tester phone , laying of cat 6 utp data cable , laying of 1 point 5 sqmm power cable , laying of 6 core single mode armoured ofc outdoor cable , laying of 25 mm dia pvc conduit 2 inches casing capping 1 inches casing capping , laying pulling of 2 5 10 20 pair telephone cable in in existing pipe , laying of 10 pair armoured jelly filled telephone cable 05mm , laying of 50 100 pair armoured jelly filled telephone cable 05mm , laying of 02 pair field telephone cable of wire 7 or 0 point 29 mm hdpe insulation , fixing and testing of information outlets , road cutting with the required depth up 40cm , excavation in soft or hard soil with the required depth , fixing of tsf joint kit for 50 pair telephone cable , fixing of tsf joint kit for 100 pair telephone cable , fixing of junction box 10 or 20 pair krone , fixing of junction box 50 or 100 pair krone , fixing of junction box 200 pair krone bid details/ 2 / 46
Tender For supplying and laying 100 mm. dia pvc pipe line behind hotel heritage to pump house at purbapara raghunathpur within ward no- 9 and 11 under bidhannagar municipal corporation. (1000 mtr. ) (fund - udma fund)
Tender For corrigendum : supply and installation of electrical fixtures and gadgets in bolpur ib at bolpur under burdwan zone in west bengal. - supply & delivery of 3 phase 415v fixed speed cassette type air-conditioner machine having cooling capacity not less than 14100w, eer 2.7 to 3.2, noise level not more than 56db. this cassette type air conditioning machine should be fitted with scroll compressors, lcd remote & all other accessories suitable for refrigerant-r32/r410a. (make-o-general /mitsubishi electric/mitshubishi heavy industries as per approved by eic/authority)., supply & delivery of 240v split air-conditioner machine having cooling capacity not less than 6875 w, isser 3.8 to 4.39, bee rating not less than 3 star, noise level not more than 46db. this split air conditioning machine should be fitted with rotary compressors, lcd remote & all other accessories suitable for refrigerant-r32/r410a. (o-general /mitsubishi electric /mitshubishi heavy industries as per approved by eic/authority)., installation, testing & commissioning of the above-said split ac outdoor unit on existing iron structure and indoor unit on wall & mending good the damages as per direction of e.i.c., installation, testing & commissioning of the above-said split ac outdoor unit by fixing iron angle unit on wall & mending good the damages as per direction of e.i.c., supply & installation of extra add-on items- hvac grade 5/8"(for suction) & 3/8"(for discharge) 1.15mm thickness copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above ac machine as per direction of eic., supply & installation of extra add-on items- hvac grade 5/8"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above ac machine as per direction of eic., supply & installation of extra add-on items- hvac grade 1/2"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above ac machine as per direction of eic., supply & laying of 4core 2.5sq.mm 1.1 kv insulation grade sheathed cu cable with gas line as per direction of eic for making interconnection/communication between indoor to outdoor unit of split type ac m/c.(make- havells/finolex/polycab as approved by e.i.c), supply and laying 5/8(20mm) heavy type pvc pipe for water drainage., supplying, fabrication & fixing of iron stand of m.s. angle size (40 mm x 40mmx6mm) for installation of outdoor unit of 4.0 tr split ac incl. drilling 2 nos holes in each angle and horizontal angle angle 40 mm x40mm x 6 mm in each stand. each stand will be properly fixing by supporting angle (25x25x5mm) and flushnut on peripheral wall as per machine configuration & load with adequate service access as per direction of eic, supplying and fixing 415 v four pole mccb of breaking capacity 25ka/35ka with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing dbs / enclosure and necessary connection (a) 160 amp fp mccb (make legrand/crabtree/siemens/l&t/ abb as approved by e.i.c) [d-8/10], supplying and fixing 240/415 v mcb of breaking capacity 10ka & c characteristics on din rail of existing dbs and necessary connection (make legrand/crabtree/siemens/l&t/abb as approved by e.i.c) [d-6/7] (a) 6-32 amp tp mcb, distribution wiring in 1.1 kv single core stranded fr pvc insulated & unsheathed copper wire (brand approved by eic) in 20mm size pvc rigid conduit fr (precision make) incl. necy. fittings as required[e-14] i) 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ecc [e-14/ 1(a)(iii)], s & f 3phase 9-15a , 415 v dol starter (make-l & t ,cat no. ss94351 or equivalent model of abb/siemens as per dierction of e.i.c) to be fixed on wall with all fixing accessories complete as
Tender For corrigendum : prov. house connection for existing and new pipe line prov. laying jointing testing pvc pipe specials sluice valve chamber chlorinator replacement of control panel repair of pump chamber ohsr and all other works complete in all respect
Tender For corrigendum : prov. house connection for existing and new pipe line prov. laying jointing testing pvc pipe specials sluice valve chamber chlorinator replacement of control panel repair of pump chamber ohsr and all other works complete in all respect.
Tender For prov. house connection for existing and new pipe line prov. water connections to hh up to wall on gi pipeline prov laying jointing pvc pipe spls for sluice valve chamber rep of control panel repair of pc ohsr and other works complete in all respect
Tender For supply and laying of pipe line 80 mm id pvc pipe village shikarpur to vishal public school niyana road and all other works contingent thereto. recommended by honble public health minister.