Tender For supply and delivery of one dissolved gas analysis (dga) test set for zonal testing unit under zonal office siliguri, power house campus, 2nd mile, sevoke road, siliguri (2nd call).
Tender For corrigendum : short term e-bid for rate contract cum supply and empanelment of surgical items - "syphilisantibody (rapid) detection kits1. the assay should be based on rapid chromatographic immunoassay for qualitative detection of antibodies (lgg, lga & lgm) to tp in serum, plasma & whole blood.2. the assay should utilize recombinant treponemal antigens i.e. tp15, tpl7, tp47 against syphilis.3. the assay should be in card format.4. adequate documents detailing the principle components, bio- safety methodologies, validity criteria, interpretation of results, performance characteristics storage conditions, limitation of assays manufacturing & expiry dates should be provides with each kit.5. the kit should have approval of the statutory authority in its country of origin.6. in case of imported kits it should be registered and licensed under the provisions of drugs & cosmetics act and rules and/or medical devices rules 2017 in india.7. in case of indigenous manufacturers should be licensed under the provisions of drugs & cosmetics act and rules and or medical devices rules 2017 issued by the competent authority defined under drugs and cosmetics act, 1940.8. the kit should have minimum shelf- life of 5/6th or 12 months (whichever is more) at the port of discharge of consignees.9. read result time should not be more than 20 minutes.10. assay should have sensitivity 100% & specificity 99 %or more with documentary evidence.11. the storage & transport temperature of the kit should be 2-30 c.12. the pack size should not be more than 50 tests wherein each test is individually", bed side leucodepletion filters for blood transfusion (for 2 unit of red cell) [ne32b] 1. filters should be able to leucodepletered cells form leukocytecontamination separately for 1 unitof red cells and for 2 units of redcells each.2. filters should be having thecapacity of log 4 reduction(99.99%)3. filters should not carry anycharges it should be neutrallycharged.4. filters material should bepolyester woven / non- woven.5. leukocytes should beconsistently averaging less than0.5x105 residual leucocytes forone unit of red cell and 0.2*106for two units of red cell. rbcrecovery should be averaging morethan 90%.6. filters should have hard / softhousing for optical monitoring.7. filtration loss should not bemore than 35 ml for one unit redcell.8. should have integrated 40 m,micro aggregate filter.9. should be us fda/ europeance certified., hepatitis b surface antigen (elisa) testing kits iv generation/high sensitiveshould have microplate elisa coated with either polyclonal or monoclonal antibodies to hbsag and either polyclonal or monoclonal antibodies in conjugate. the assay should be able to detect all the 11 subtypes (ad & ay subtype) including mutant strains. the assay should be able to detect surface antigen to hepatitis b virus., hbsag (rapid test)
Tender For work contract of tube leakage attending, gasket replacement & hydraulic test of gc-1, gc-2, lph-2,3,4 & vent condenser and flushing, cleaning & tube leakage attending work of bfp coolers on as & when required basis at unit 3 & 4, cstps chandrapur
Tender For providing of custom bid for services - carrying out online helium leak detection test for condenser and connected negative pressure parts of unit 1 to 4 (210 mw) and unit 5 to 6 (250mw) mtps, dvc
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; hydraulic test bench; service provider
Tender For supply of design and development of laser interrogator system including hardware firmware and software gui , supply of integrated laser card along with accessories and cables , supply of 5 wavelength channel master laser source assembly with dwdm module and chassis , supply of michelson interferometer assembly with acoustically isolation enclosure and cables , supply of interrogator and rtm pcbs along with cables and mechanical appurtenance and spares components , supply of standard vme 64x chassis with controller and display , development tool chain , spares and test tools , qualification test charges for laser system and interrogator unit
Tender For purchase of digital and analog communication lab equipment(tansche) - digital and analog communication lab equipment(tansche), digital ic trainer kit:1. equipped with 16 high-visibility leds for monitoring experimental outputs and logic status indication. 2. dedicated driver circuitry provided for reliable operation and protection of all 16 leds during experimentation. 3. all 16 driver input lines are terminated through banana connectors for flexible and easy external interfacing. 4. includes 16 spdt toggle switches for generating manual logic input conditions in digital electronics experiments. 5. additional 16 leds provided to display the real-time status of individual switch operations. 6. one terminal of each spdt switch is externally accessible through banana sockets for convenient circuit connections. 7. built-in variable clock generator enables pulse generation for sequential and timing-based 8. digital experiments. 9. frequency adjustment provided through potentiometer and rotary switch combination for precise clock selection. 10. clock output is terminated through banana connectors for quick integration with external circuits and trainer modules. 11. features dual 7-segment led display with 7447 decoder/driver ic for bcd to display 12. conversion experiments. 13. inputs of the 7447 drivers are terminated at banana connectors for direct digital logic interfacing. 14. includes solderless breadboard for rapid circuit prototyping and reusable experimental setup development., amplitude modulation trainer kit:1) on board carrier and modulating signal generator with amplitude and frequency adjustable 2) carrier and modulating signals are provided in the unit with frequency variable. 3) in-built regulated power supply 4) on board envelope detector 5) schematic diagram provided in the front panel modulating signal frequency : (300hz-3 khz) amplitude : (0-5) v carrier signal carrier signal frequency : 10 khz - 50 khz amplitude : (0-15) v type of modulator : 1. ring modulator 2. transistor based modulator method of modulation : 1. under modulation 2. critical modulation 3. over modulation, fm trainer kit 1) on board sine wave generator 2) provision to study modulation & demodulation in the same unit 3) test points to study different waveforms 4) in-built audio power amplifier 5) mic pre amplifier 6) built-in power supply 7) sine wave generator : frequency - 100hz to 1.2 khz with amplitude adjustable, (0-5v) 8) fm modulator : direct fm 9) carrier frequency : 20 khz (low), 367 khz(high) 10) fm demodulator : pll detector, quadrature detector, foster seelay discriminator / phase discriminator, ratio detector are provided. 11) audio power amplifier : gain 100 12) mic pre amplifier : gain 20, ask, fsk, psk trainer kita s k modulation & demodulation trainer on board data generator circuit. auto / manual mode (data generation) external patching provision provided between the modulator and demodulator. built-in power supply. modulator and demodulator are separately provided. easy interconnections are made by patch cords. mode : auto / manual input data rate : 800hz to 2 khz any external ttl compatible sequence with frequency up to 2.1 khz. carrier frequency : 20 khz power supply ratings: 230v + 10%, 50hz. f s k modulation & demodulation trainer three types of i/p sources - manual input , square input , rs232 input fsk modulator with, mark frequency: 1070 hz space frequency: 1270 pll based fsk demodulator output provided through bs2 connector and serial port. built-in power supply. p s k modulation & demodulation trainer on board programmable data generator on board carrier generator mimic diagram in the front panel type of modulator : balance modulator type of demodulator : balance demodulator binary inputs - 8-bit data length 50 khz, clock carrier inputs frequency : 200 khz amplitude : 2 v pp level converter : unipolar to bipolar supply ratings ac input (230v, 10%, 50hz) dc output (+12v,-12v, +5v, gnd, pam, pwm, ppm trai