Get complete information related to latest Digital Ultrasound Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Digital Ultrasound Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Digital Ultrasound Tenders.
Tender For supply of pressure guard 300/250 kva of bio vacuum toilet system in train -18 drawing no: part no 50123 of m/s evac or equivalent kbi part no [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For corrigendum : supply delivery and fitting fixing of gaseous chlorination items for the standby system of clear water pumping station and supply of 1 no empty chlorine tonner at ibs uporgora under chhatna, saltora block sub-surface water based piped water - supply and delivery of gaseous chlorination unit spares (0-10kg) & (0-4kg)kg/hr. require of wallace & triman evoqua, vacuum regulator (wall/cylinder mounted)with auto switchover facility, capacity 0-10 kg/hr max, evoqua make s10k scale controller, capacity 10.0kg/hr, manual control, evoqua make 1 injector suitable for 40 psi backpressure, fitting fixing of the above new supplied spares on the existing position part by part with new ejector pipe line with necessary fitting materials and necessary welding job by expert mechanical complete the job as per direction of eic and as per is:10553., supply and delivery at site of 1000 kg empty chlorine tonner hydraulic test pressure 30 kgf design as per asme section viii div.1 with hot-forged steel hook and a safety tongue piece, add: 18% gst, add: 1% cess
Tender For corrigendum : supply delivery and fitting fixing of gaseous chlorination items for the standby system of clear water pumping station and supply of 1 no empty chlorine tonner at intake kukrakuri under chhatna, saltora block sub-surface water based piped - supply and delivery of gaseous chlorination unit spares (0-10kg) & (0-4kg)kg/hr. require of wallace & triman evoqua, vacuum regulator (wall/cylinder mounted)with auto switchover facility, capacity 0-10 kg/hr max, evoqua make s10k scale controller, capacity 10.0kg/hr, manual control, evoqua make 1 injector suitable for 40 psi backpressure, fitting fixing of the above new supplied spares on the existing position part by part with new ejector pipe line with necessary fitting materials and necessary welding job by expert mechanical complete the job as per direction of eic and as per is:10553., supply and delivery at site of 1000 kg empty chlorine tonner hydraulic test pressure 30 kgf design as per asme section viii div.1 with hot-forged steel hook and a safety tongue piece, add: 18% gst, add: 1% cess
Tender For supply of heavy duty rugged vacuum cleaner wet & dry for industrial use pulse jet vacuum cleaner with all standard accessories. i. power: 5.5 kw-7.5 hp ii. voltage: 415v-50hz, 3phase iii. max. vacuum: 500 m3/hr or more with latch locks facility iv. collection cap: 80 ltrs to 100 itrs v. accessories: round brush with adapter-01 no. vi.floor br?sh: 01 no. vii. pvc flat nozzle: 01no. viii. 04 feet pvc pipe: 02 no. ix. 01 feet pvc piper 01 no. x. flexible hose 1x 15 meters: 01-x1 power cable 1x 15mtrs: 01 with p.v wheels polyester. cartridge filter xii.high vacuum & maintenance free blower xiii. automatic cleaning system to avoid filter chocking xiv. hepa filter xv. liquid sensor xvi. stainless /flame proof mode other details as per specification. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply and installation of one rake set of vacuum evacuation system for vande sleepertrain set to specn.no.rdso/2017/cg-06 rev-04 with annexure-train set-ad, rev-02(latest).one rake consists of 2 dtc (3t) coaches (3 western type vacuum evacuation system per coach), 21 tc/mc/ndtc (2t &3t) coaches ( 2 western + 2 indian type vacuum evacuation system per coach) and 1 ndtc (fac) coache (2 western + 1 indian type vacuum evacuation system per coach. total 93 vacuum evacuation system required per rake. (50 western type and 43 indian type). please visit icf vendor portal for downloading drawing https://vp.icf.gov.in/vendtendordetnew.php using key:07269csaort2159 [ warranty period: 72 months after the date of delivery ] ]
Tender For corrigendum : rate contract for medicine - stainless steel abdominal hysterectomy set, n.s.v set (s.s), g.v set, self abdominal detractor, m.t.p set., vaccine carrier (small size), x-ray digitalisation with high-end cr system (with installation & 1 yers. warrenty) console software with mulitmodality work station the cr system should have advances workstation provided with 17" high resolution monitor, keyboard & ouse, with the fol., digitalultrasound machine colour dopler (high resolution ) with 4 probe, semi auto analyzer, fully automated bio-chemistry analyzertechnical specificationsthroughput-150t/hr (constant with both mono and double reagent)system function-random access/stat/batchtest method-end point, fix time, kinetic, (single/double reagents chemistry, mono/ bio-chromatic measurements)calculation methods-1 point linear, 2 point linear, exponential, logit log3p, logit log 4 p, logit log 5p, spline, line graph, k factorblank-reagent blank, sample blank, pre sample blank, pre reagent blanksample tray-40 position, sample volume :2-30 ui, 0.1 ul increment, micro cup, & test tube can be used for samplereagent tray-80 position, reagent volume: 20-300 ul, 1 ul incrementmixing system-teflon coated mixersample probe-1 needle with liquid detector, shock sensoroptics-halogen-tungsten lamp, absorbance range: 0-4.0 abs resolution: 0.0001 abs.diffraction photometry with wave length: 340, 405, 450, 505, 546, 578, 630, 700nm & 4 more optionswash station-12 step washing, 4 needle wash station, 1 dry pad, external needle cleaningcalibration-linear and non-linearqc-multi-level qc setup with levy-jennings graph and westgrads multi rules with mean sd, and cvwater consumption-not more than 6l/hrtemperature-reagent: 2-14 c (24 hr refrigeration), reaction cuvette: 37c 0.1 humidity- 80%system interface-usbpower requirement-ac 220v 10%, 50/60 hzdimensions-750 mm*560mm*530mm, hotair oven, binocular microscope (olampus), centri fuge machin (good quality), micropipette (0-50 microliter), micropipette (0-500 microliter), micropipette (0-1000 microliter), microtips (0-50 microliter), microtips (0-1000 microliter), bed side screen with cloth 1"round pipe with wheel, sponge holding (all size), artery forceps 6" curved, artery forceps 6" straight., artery forceps 8" curved, artery forceps 8" straight., artery forceps 4" straight., alliys tissue forcep (all size curved straight), mosquito forcep (all size curved straight), scissor 6 " curved (all size), scissor 6 " straight (all size), scissor mosquito straight. (all size curved, straight), diatheromy (machine), laparoscopic instrument full set (best quality), needle holder 8 "curved, needle holder 8 " straight, needle holder 6 "curved, needle holder 6 " straight, needle holder 4 "curved, needle holder 4 " straight, doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside, elisa reader with washer mechine with printer & ups., doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside ( best quality), fully automated chemiluminescence analyzer(clia) 1. system should be fully automated walk -away with continuous loading facility.2. analyzer should have able to perform thyroid, bone, cardiac, fertility, diabetes and anemia profile test.3. working principle of system should be micron super paramagnetic particles platform with alp labeled reagents and amppd substrate.4. must have 3 phase magnetic separation with precisely controlled temperature.5. analyzer should have photon counting detection mode with photomultiplier photo counter with led reference module.6. the analyzer must have vortex non-touch mixing which can reduce carryover., 7. throughput of the system should be more than 180 tests in a hour.8. system should have 15 reagents onboard with onboard 2 -8 nonstop refrigeration facility 9. system should have at least 50 sample positions and continuous loading facility.10. system should have cont
Tender For supply, delivery, installation and commissioning for medical gas pipeline system and vacuum suction pipeline system at trauma centre, civil hospital, aizawl
Tender For supply of bowl sensor (liquid level guard) of bio vacuum toilet system in train-18/ vande bharat express coaches drawing no: part no 43376 of m/s evac/ kbi part no. kn-110792 [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply, delivery, installation and commissioning for medical gas pipeline system and vacuum suction pipeline system at trauma centre, civil hospital, aizawl