Web Analytics Made Easy - StatCounter

Digital Amp Meter Tenders

Get complete information related to latest Digital Amp Meter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Digital Amp Meter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Digital Amp Meter Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :40700895 Due date: 30 Jun, 202530 Jun, 2025 NA
Tender For supply and testing of star delta starter panel board suitable foe 7.5 hp submersible pump mo tor set 3 phase 415 volt ac complete as per following specification:-(1)push button with light 230v-0 1 nos. (2) auto tie switch 16 amp 230 v -01 nos. (3) single phase preventor vsp2 415v ? 01 nos. (4) digital ampere meter with selector switch ? 01 nos. (5) digital voltmeter 500v -01 nos (6) mccb 3 pole breaking c apacity 25 ka 32 amp. ? 01 nos. (7) digital hour meter 230 v ? 01 nos (8) hrc fuse unit 32 a complete ? 03 nos. (9) over load relay 14-23 amp ? 01 nos. (10)two way toggle switch 10 amp for manual auto ? 01 nos. ( 11) star delta timer 0-60 sec. ? 01 nos. (12) 03 pole contactor 32 amp 3 phase with aux. block (2 no+2 nc ) ? 03 nos.(13) ct 50/5 per unit ? 03 nos. (14) control fuse ? 03 nos. (15) water level control guard of 3 pro de system ? 01 nos. (16) average dimension 640x500x290 mm.(17) led indicating lamp for motor on, mot or trip & ryb phase indicator ? 05 nos. (note:- all switch grear separate ) [ warranty period: 30 mo nths after the date of delivery ]

Central Government And Public Sector

CTN :40477848 Due date: 24 Jun, 202524 Jun, 2025 2.20 Lacs
Tender For corrigendum : supply of ems service te railwaypura - pvdg reneted oump for use , replace 50mm gi b class pipe , sf 3inch half turn valve gi , sf 2inch half turn valve gi , modify 3inch water line by pvdg 3inch flange , modify 3inch water line by pvdg 3inch nipple , modify 3inch water line by pvdg 3 inch tee , modify 3inch water line by pvdg 2.5 inch nipple , modify 3inch water line by pvdg 3 and 2.5 inch socket , modify 3inch water line by pvdg 2.5inch coupler , modify 3inch water line by pvdg 2 inch nipple , modify 3inch water line by pvdg 2 inch tee , sf 50 mm nrv , plumbing work for priming assembly , arrangement of automationof extg water supply by pvdg 5 hp dol starter , arrangement of automationof extg water supply by pvdg 63a 4p changeover mcb , arrangement of automationof extg water supply by pvdg auto timer 24 hrs , arrangement of automationof extg water supply by pvdg wlc , arrangement of automationof extg water supply by pvdg 63a 4p mcb , arrangement of automationof extg water supply by pvdg 3.5c 50 sq mm et , arrangement of automationof extg water supply by pvdg 200 a terminal , sitc 10kvar app capacitor , rewind ex fan ped fan motor upto 200w , rewind ceiling fan motor upto 1400 mm , replace 4 ft 36 w t rod , replace 4 ft 18w led , replace 4 ft 230 v tl starter , replace electronic choke for tl , replace side holder for tl , replace 5 amp piano switch , sdrg 1no 1.5 sq.mm frls cu wire , s drg 2no 1.5 sq.mm frls cu wire , replace 2 module electronic regulator , refill fire extgshr 4.5kgs , pvdg hosepipe for fire extgshr 4.5kgs , sf 12v 26ah battery fda system , conduct fire drill for bldg g plus 3 flr , service 11kv substation with ht panels , repair of substation panel by repacing led ind lamps 220v , repair of substation panel by repacing 2 to 4 a hrc fuse , repair of substation panel by repacing lml1 contactor kit , repair of substation panel by repacing bimettalic ol for blower mn2 , repair of substation panel by repacing spp ol relay mpr1 , repair of substation panel by repacing 8 pin 220v pla relay , repair of substation panel by repacing 0 to 400a ammeter ac , repair of substation panel by repacing 0 to 30 a ammeter ac , repair of substation panel by repacing 0 to 500v voltmeter ac , repair of substation panel by repacing dc ammeter 96mm , repair of substation panel by repacingdc voltmeter 96mm , repair of substation panel by repacing selector switch , b check service of dg set 320 kva , supply smps battery charger 24v 10a , sf 12v 130ah mf battery for ea set , supply brass battery terminals , pvdg led ind lamps 220v ea set , sfixing bradided fuel pipe for ea

Central Government/Public Sector

CTN :40682174 Due date: 11 Jul, 202511 Jul, 2025 NA
Tender For supply, installation and commissioning of portable constant current battery charger suitable for locomotives starter batteries (each battery 8v, 450 / 500ah ) input voltage 415v ac, 3 phase, 50 hz, o utput voltage range : 0 to 110v dc (adjustable), output current : 0 to 75 amps (adjustable), with conditio ns as (1) suitable for charging of atleast 8 batteries 8v/500ah (2)unit inbuilt with digital dc volt meter 0 - 2 00v, digital ampere meter 0 - 100 amp (3) mode of charging constant voltage and constant current (4) inco ming and outgoing protected with mcb/ overload relay/ dc fuse / phase fail potentiometer. [ warranty p eriod: 30 months after the date of delivery ]
 Loading, Please wait...

Connect us via What's Up