Tender For provn of ring main unit near ss no 16 at arty centre special repair for replacement of 4 pole structure with ring main unit at arty centre and aop area and special repair to existing electrical infrastructure near adm block of caats and near jcos m
Tender For repair maint of water supply distribution network raising main leakage repair attending day to day water related complaints electrical infrastructure feeder pillar box panel periodical servicing of protetive devices earting and certain miscellaneous em works
Tender For corrigendum : construction of 150 bedded critical care hospital block b g 7 at aiims patna under pradhan mantri ayushman bharat health infrastructure mission pm abhim. sh providing inspection vehicle for the office of executive engineer and senior manager electrical iit and aiims project patna ped cpwd patna.subwork/packages:providing inspection vehicle for the office of executive engineer and senior manager electrical iit and aiims project patna ped cpwd patna
Tender For stage contract for carrying out various electrical maintenance works including sitc, itc of various line materials and distribution substations and dismantling of existing deteriorated out lived electrical infrastructure for the year 2026-27 under th - supply, installation, testing and commissioning of 3-phase 25 kva distribution transformers with bimetallic terminal connectors energy level-2, (al wound ), and with lv cable box having detachable aluminium gland plate, supply, installation, testing and commissioning of, 3-phase 63 kva distribution transformers with bimetallic terminal connectors energy level-2, (al wound ), and with lv cable box having detachable aluminium gland plate, supply, installation, testing and commissioning of, 3-phase 100 kva distribution transformers with bimetallic terminal connectors energy level-2, (al wound ), and with lv cable box having detachable aluminium gland plate, supply, installation, testing and commissioning of, 3-phase 200 kva distribution transformers with bimetallic terminal connectors energy level-2, (al wound ), and with lv cable box having detachable aluminium gland plate, supply, installation, testing and commissioning of, 3-phase 250 kva distribution transformers with bimetallic terminal connectors energy level-2, (al wound ), and with lv cable box having detachable aluminium gland plate, sitc of 11 mtr long st poles 410, sp-56 including transportation, manual, mechanical carriage, delivery at site with pit excavation, refilling the pit with soil, boulders., sitc of 9 mtr long st poles 410, sp-33 including transportation, manual, mechanical carriage, delivery at site with pit excavation, refilling the pit with soil, boulders., sitc of 8 mtr long st poles 410, sp-15 including transportation, manual, mechanical carriage, delivery at site with pit excavation, refilling the pit with soil, boulders., sitc of 8 mtr long pcc poles including manual, mechanical carriage, excavation of pole pits with inscription of permenent marking on each pole "name of scheme-2019-20/xx" (xxx mean pole numbers say 01,02...) in white paint in backgound of green paint at conspicious place, providing & fixing of pole earthing as per rec standard as per j-1 (spiral earthing) drawing, supply,fixing of spike earthing rod 20mm 2,5 mtr long with gi strip (25x3)mm, supply and painting of each pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint), providing, errection, testing & commissioning of channel cross arms, v-cross arms, sub-station channels & angle iron braces, transformer beltings, including back clamps for fixing cross arms etc fabricated out of galvanized iron of different sizes (rec standard) & to be fixed with gi nuts & bolts and washers., providing, errection, testing & commissioning of channel cross arms, v-cross arms, sub-station channels & angle iron braces, transformer beltings, including back clamps for fixing cross arms etc fabricated out of mild steel of different sizes (rec standard) & to be fixed with gi nuts & bolts and washers., providing & and fixing of 11 kv pin insulators (polymer) with pins ( 5 kn), providing & fixing of 11 kv, g.o ab switch , 3-phase, 200a (09 insulator post type) with arragement for pad locks & operating rod . the operating rod should be g.i pipe (b-class) of 25 mm dia of requisite length., providing & fixing of 11 kv horn, gap fuse 3-phase 100a, providing & fixing of 11kv link set 3-phase, 200 a (station type), sitc of 11kv isolator double break, 3-pole, 630 amps, horizontal mounting type , with earth switch, providing & fixing supply and installation of gapless surge arrestor,9 kv,10 ka, la with (polymer) housing, station type, providing & fixing of lt fuse set of suitable capacity for 63kva,100kva,200kva (as per tender drawing attached), providing & fixing of 11 kv disc insulators (polymer) complete with fitting( 45 kn), providi
Tender For supply, installation, testing and commissioning (sitc) of equipment for smart classroom setup - interactive flat panel display with necessary mounting accessories, digital teaching podium with integrated mini pc and audio system, full hd visualizer, ptz cameras for lecture recording and streaming, online ups with adequate battery backup, air conditioning units for the classroom, classroom furniture including student chairs, teacher table and chair, networking and electrical infrastructure, miscellaneous classroom support equipment and furnishing items
Tender For corrigendum : procurement of 155, 9-m fully built pure electric ac buses with chargers & down-streaming electrical infrastructure (with installation &commissioning) and comprehensive maintenance for10 years for 07 cites of rajasthan
Tender For camc/amc shall include routine inspection, preventive maintenance, servicing, testing, cleaning, troubleshooting, fault rectification and breakdown support for hvac/vrv systems, fire alarm pa systems, cctv systems, epabx systems, electrical installations, it infrastructure and av systems including all associated equipment, panels, controls, cabling, accessories and minor consumables to ensure safe, reliable and uninterrupted operation as per oem recommendations