Tender For piped water supply scheme for on risk & cost piped water supply scheme for village- koti(imlidand,khaspara,korwapara) koti(panditpara) koti (daridih, pateratola, purankoti) block- wadrafnagar district – balrampur(c.g.)construction, testing and commissioning of r.c.c. elevated service reservoir of 00 kl capacities – 00 no. & staging 12 mtr& staging and steel structure 09 m height & 10 kl (5000l x 2no.)- 00 no.} pe tank & elevated service reservoirs of rcc staging and hdpe slim tank of capacity 5000 ltr of 00 no. 9 mtr staging (with switch room of size 1.8mx1.8mx3m) and 10000 ltr of 00 no. 12 mtr staging.including providing and fixing of ci double flange pipe, double flange specials & di double flange soft seated sluice valve including construction of suitable r.c.c. valve chamber.providing, laying, jointing, interconnection, testing and commissioning of rising main upvc class 10 kg/sqcm 90 mm dia 00 m & hdpe 75mm dia 00 m & 63 mm dia 840 m., distribution upvc class 6kg/sqcm 90mm dia. 00 m., 110 mm dia. 00 m., 140 mm dia. 00 m. 160 mm dia. 00 m.& distribution hdpe class 6kg/sqcm 63 mm dia. 550 m., 75 mm dia. 1000 m.with suitable joints gi pipe, valve, specials and all fittings including all allied civil works, supplying & installation of energy taging n five star bee rating isi marked required capacity single phase / three phase, 50 hz, 220v,, deep well submersible pump stainless steel body, suitable for 4”/6” tube well with contral panel starter suitable for submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,ss/nylonwireropeandconnection cable including verification of tubewell yield& electric connection from cspdcl, construction of brick masonry switch room, construction of boundary wall around the over head tank, installation of electro chlorinator , construction of chlorinator room of providing functional household tap connection (f.h.t.c. 0 ) in individual households and government instiution etc. complete with trial run of 03 months after that o&m of 06 months under village-koti(imlidand,khaspara,korwapara)koti(panditpara) koti(daridih,pateratola,purankoti) block- wadrafnagar district – balrampur(c.g.)
Tender For piped water supply scheme for on risk & cost piped water supply scheme for village- darridih ( uraopara, purvtola ,khaspara ) block- balrampur district – balrampur(c.g.)construction, testing and commissioning of r.c.c. elevated service reservoir of 00 kl capacities – 00 no. & staging 12 mtr& staging and steel structure 09 m height & 10 kl (5000l x 2no.)- 00 no.} pe tank & elevated service reservoirs of rcc staging and hdpe slim tank of capacity 5000 ltr of 00 no. 9 mtr staging (with switch room of size 1.8mx1.8mx3m) and 10000 ltr of 00 no. 12 mtr staging.including providing and fixing of ci double flange pipe, double flange specials & di double flange soft seated sluice valve including construction of suitable r.c.c. valve chamber.providing, laying, jointing, interconnection, testing and commissioning of rising main upvc class 10 kg/sqcm 90 mm dia 00 m & hdpe 75mm dia 00 m & 63 mm dia 00 m., distribution upvc class 6kg/sqcm 90mm dia. 00 m., 110 mm dia. 00 m., 140 mm dia. 00 m. 160 mm dia. 00 m.& distribution hdpe class 6kg/sqcm 63 mm dia. 1300 m., 75 mm dia. 127 m.with suitable joints gi pipe, valve, specials and all fittings including all allied civil works, supplying & installation of energy taging n five star bee rating isi marked required capacity single phase / three phase, 50 hz, 220v,, deep well submersible pump stainless steel body, suitable for 4”/6” tube well with contral panel starter suitable for submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,ss/nylonwireropeandconnection cable including verification of tubewell yield& electric connection from cspdcl, construction of brick masonry switch room, construction of boundary wall around the over head tank, installation of electro chlorinator , construction of chlorinator room of providing functional household tap connection (f.h.t.c. 46 ) in individual households and government instiution etc. complete with trial run of 03 months after that o&m of 06 months under village- darridih ( uraopara, purvtola ,khaspara ) block- balrampur district – balrampur(c.g.)
Tender For 3 nos supply, installation, testing and commissioning of solar pump controller/vfd complete with mppt technology, protections, auto operation, compatible with existing solar pump system including all accessories with submersible dc motor pump set at block amet.
Tender For 3 nos supply, installation, testing and commissioning of solar pump controller/vfd complete with mppt technology, protections, auto operation, compatible with existing solar pump system including all accessories with submersible dc motor pump set at block amet.
Tender For 3 nos supply, installation, testing and commissioning of solar pump controller/vfd complete with mppt technology, protections, auto operation, compatible with existing solar pump system including all accessories with submersible dc motor pump set at block amet.
Tender For corrigendum : supply of various consumable material at emd -1 lighting dept. stps. - flat cable 3 corex4 sqmm with copper conductor for submersible motor, flexible copper wire 1 corex2.5 sqmm (36/0.3 mm)1100v(1 coil is equal to 90 meter), flexible copper wire 1 corex1.5 sqmm (22 / 0.03) voltage grade up tp 1100 volt conf to is- 694, copper cable 2 cx1.5 sqmm, pvc twin wire 2.5mm sqr., self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm width x 7.5 mtr length x 0.125 mm thickness, of red colour, self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm width x 7.5 mtr length x 0.125 mm thickness, of yellow colour, self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm width x 7.5 mtr length x 0.125 mm thickness, of blue colour, self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm width x 7.5 mtr length x 0.125 mm thickness, of black colour, self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm width x 7.5 mtr length x 0.125 mm thickness, of green colour, porcelin kit kat fuse 16 amp, porcelain kit kat fuse 63 amp, 415 v , ac, porcelain kit kat fuse 100 amp, 415 v , ac, porcelain kit kat fuse 200 amp, 415 v , ac, din rail mounting channels, ring spanner set model 1812 taparia make, double ended spanner set dep 12, adjustable screw spanner size 8" (200 mm) p.no.1171-8 p, screw driver (tester) taparia product no: 818.special with neon bulb, generally confirming to is 5579-1985 grade - ii, yellow handle,, taparia combination plier, product no.1621-8,210 mm, digitalinsulationtester, range-0-2000 m-ohm, selectable test voltage-250/500/1000 v dc with rechargeable battery, digital clamp on meter lcd display with backlight, 3-3/4 digit., alluminium ladder self supported a type having 05 feet length, long nose plier insulated with thick c.a. sleeve,165 mm length, taparia make tool, allen key set, product no aki 10, allen key set mm size (09 piece) 1.5,2,2.5,3,4,5,6,8,10 mm, hand drill machine size 13mm, hand grinder machine., aluminium tube terminals10.0 mm2, m.6, aluminium tube terminals16.0 mm2, m6, aluminium tube terminal 35 sqmm,m 8, aluminium tube terminals50.0 mm2, m10, aluminium tube terminals70.0 mm2, m8, aluminium tube terminals95 .0 mm2, m10, pin terminal 1.5 mm2, pin terminal 2.5 mm2, aluminium in line connector25.0 mm2,, 35mm alluminium in line connector als-2"dowell", aluminium in line connector 70 mm2, 95 sqmm crimping alluminium type in-line connectors cat no: hai-15 hex make, crimping tools capacity: 10 mm2 to 185 mm2., crimping tools, capacity: 6 mm2 to 50 mm2., alluminum ring type lug 25 sq. mm, pvc saddle 10 mm, pvc saddle 15 mm, pvc saddle 20 mm, pvc saddle 32 mm, multistrend copper flexible wire 1 core x 4.0 mm2, (7 strendes) pvc (double) insulated, without armourr, 1.1kv grade (100m/coil)
Tender For repair/replacement of external electric supply distribution network with other connected items at malad, marve and kandivali under ge (n) santacruz, mumbai - supply, install, testing & commissioning pedestal cubical type double door lt bus bar chamber box of suitable size factory made modular construction fabricated out of 3 mm thick crca sheet, angle iron, channels, epoxy powder coated to give a superior finish , outdoor type , totally enclosed dust & vermin proof with locking arrangements front & back side opening system including rain shed, busbar chamber should be suitable for accomodating all aluminium bus bar strips (50mm x 10mm x 04 nos) & gi strip for earth fixed on porcelain insulators, and one independent metering module suitable for accomodating three phase volt meters & ammeter digital type, indicator lamps, cable entry/exits cut outs at bottom part, with fixing arrangement on pcc (1:3:6) type c-2 bed block with studs, bolts, nuts & washers, danger notice board with scull suitable for 415 volts or required size to be fixed on pannel including dismantling of old bus bar panel all as specified and directed by engr-in charge.notes:-(a) aluminium bus bar duly covered with colour coded shrinkable sleeves of required size for phases and neutral - 01 set(b) mccb 4 pole , ics=100%icu- 25 ka, 415 volts, 100 amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 nos.(c) digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programable ct of appropriate ratio.-01 no make- imp/automatic electrical(ae)/ l&t / havells/ meco(d) panel indicating lamp neon/led type (red ,yellow & blue) with lamp holders - 03 nos(e) panel instrumental wiring with frls suitable size but not less than 2.5 sqmm copper wire single core - 01 job(f) necessary sizes of lugs for fixing of cables in bus bar deemded to be included rate quoted by the contractor.make of mccb & mcb: larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 400 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:- larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 160 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 16 ka 100 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 250 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb all as specified and directed by engr-in-charge make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supplying, laying,connecting, testing & commissioning lt ug pvc insulated, heavy duty, 1100 v grade electric cable with aluminium conductor of size 16 sqmm x 4 core, laid in trenches or passing through pipe or fixed to wall, making all connections with and including provision of necessary glands, lugs, bushing etc as required including taking down old unserviceable cable complete all as specified and as directed by engineer-in-charge of following sizes:-note : earthwork excavation, dwc
Tender For repair / maint of split acs 2/1.5 ton , windows acs 2 / 1.5 ton , voltage stablizers and connected items installed at command hospital (wc) and other various location in aor of age e/m ch - servicing of split type ac of capacity 2/ 1.5 tr after disconnecting all incoming and outgoing electric connection, water drain pipe line connection etc. and wash with approved chemical mixed water with the pressure pump, after servicing cleaned all the disturbed area and reassembling the water/electric connection and testing for entire satisfaction of engr-in-charge., all as per item no. 1 here-in-above but window type ac 2/1.5 tr capacity., supplying and charging of refrigerant gas r-22 only after vacuuming dehydration, leak testing of the system as per standard practice testing for proper cooling effects and satisfactory performance complete all as specified and as directed by engr-in-charge for room split/window type ac of capacity 2/1.5 tr., all as per item no: 3 above but gas r-32, all as per item no: 3 above but gas r-410a., all as per item no: 3 above but gas r-134a., taking out defective capacitor of capacity 50+6 mfd after disconnecting all incoming and outgoing electric connection including supply & fix new capacitor on same place and testing complete all as specified and as directed by engr-in-charge, all as per item no:7 here in above but of capacity 45+4 mfd ., all as per item no:7 here in above but of capacity 45 mfd ., all as per item no: 7 here in above but of capacity 6 mfd ., all as per item no: 7 here in above but of capacity 4 mfd ., supply & fixing as in replacement copper pipe 1/2" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 1/4" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 5/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 3/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply and fixing of insulation foam for copper pipe of size 1/2" after removing old one., supply and fixing of insulation foam for copper pipe of size 1/4" after removing old one., supply and fixing of insulation foam for copper pipe of size 5/8" after removing old one., supply and fixing of insulation foam for copper pipe of size 3/8" after removing old one., supply and fixing as in replacement of pvc flexible pipe 15 mm dia including any fittings as required complete inclusive of any type of leakage testing., all as per item no: 20 above but pipe of 20 mm dia., supply and fixing as in replacement of pvc water drain pipe 25 mm dia complete inclusive all fittings and any type of leakage testing., material and labour for sub main wiring with 2 x 2.5 sqmm +1 x 2.5 sqmm single core flame retardant pvc insulated unsheathed cable with stranded copper conductor drawn in and including heavy grade frlsh pvc concealed conduit isi marked with all accessories on walls and making good the disturbed surfaces including all conduits fittings, clamps guittes etc for earth dbs and boxes with proper thimbles all as directed by engr-in-charge. note :02 run of 2.5 sqmm , 01 run of 2.5 sqmm cable and 01 run of conduit shall be measured as one unit and paid accordingly., all as per item no: 23 here in above but of size 2x 4 sqmm +1x 4 sqmm., m&l cutting chases, pinning in stone concrete block or slab walls & making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring ,etc., and making good, cutting exc. 10 cm girth., supply and fix as in replacement of rigid non-metallic pvc conduit of size 20
Tender For providing installing testing commissioning and handing over of ahu/ cs ahu and other allied works for burn unit ward, area-32 of level-iii, block a, gmch, sector - 32 chandigarh