Tender For supply of electrical cable lugs,electrical cable lugs,electrical cable lugs,electrical cable lugs,steel pipes for water and sewage as per is 3589,steel pipes for water and sewage as per is 3589,miniature circuit breakers (mcb) for ac operation marked to is/iec 60898 (part 1),pvc insulated unsheathed cable with flexible conductor isi marked to is 694,aluminium sheet 8 inch x4 inch x 0.56 mm,grating cp round 125mm,grating doom ptmt round 100mm dia,pvc shelf 450mm,pvc waste coupling for kitchen sink,pvc waste pipe 32 x 800mm,mcb db single phase 4 way,mcb db spn 4 way,socket reducing 20x15mm,thermostate for geyser,cp health faucet 125 mm long cp pipe,iwc 580x440 vitreous china white,steel soap tray heavy duty,heating element round 1500watt
Tender For supply of led batten light (led tube light) (v2),self ballasted led lamps (led bulb) (v3) conforming to is 16102 (part 2) (under bis scheme - ii),self ballasted led lamps (led bulb) (v3) conforming to is 16102 (part 2) (under bis scheme - ii),self ballasted led lamps (led bulb) (v3) conforming to is 16102 (part 2) (under bis scheme - ii),led luminaire for floodlight conforming to is 10322 (part 5/section 5) (v3) (under bis scheme - ii),led luminaire for road and street lights conforming to is 10322 (part 5/section 3) (v3) (under bis scheme - ii),plasticized pvc tapes with non-thermosetting adhesive for electrical purpose (v2) isi marked to is 7809 (part 3/ sec1),led garden light (v2),led garden light (v2),led luminaire (recessed luminaire) (ceiling light) conforming to is 10322 (part 5/section 2) (v4) (under bis scheme - ii),led bulkhead light,moulded case circuit breakers (mccb) conforming to is/iec 60947 (part 2),led luminaire for floodlight conforming to is 10322 (part 5/section 5) (v3) (under bis scheme - ii),led l
Tender For nsac and substation fss - 1. fire alarm control panel conventional, conventional, 2-zone supply, installation, testing <(>&<)> commissioning complete with visual indications for alarm, fault, short/ open circuit, zone mimic board etc. 2-zone sector panel / conventional panel as per is standards (make and model: ravel) conventional, 2-zone supply, installation, testing <(>&<)> commissioning complete with visual indications for alarm, fault, short/ open circuit, zone mimic board etc. 2-zone sector panel / conventional panel as per is standards (make and model: ravel) 2. supply & fixing of optical smoke with mounting base, led (make and model: (apollo, siemens, honeywell, simplex, notifier) detector base mounting base for smoke detector (make and model: ravel) detector (photoelectric type) complete with base, led indication, suitable for ceiling mounting, conforming to is 2189 - (make and model: ravel) 3. supply & fixing of manual call point (make and model: ravel) (mcp), break glass type / resettable type, complete with mounting box, suitable for fire alarm system, conforming to is 2189- (make and model: ravel) 4. supply & fixing of hooter cum strobe, (make and model: ravel) electronic hooter with flashing strobe light, suitable for indoor use, conforming to is 2189 - (make and model: ravel) 5. supply & laying armoured cable 21.5 sqmm (frls/swa) 21.5 sqmm (frls/swa) - make reputed 6. supply, installation, testing & electrical, interconnection, loop termination, functional tests commissioning of online 1kva ups with minimum 30 minutes backup for fire alarm panel - make apc / vertiv / eaton or equivalent 7. testing, commissioning, as-built drawings, test certificates, o<(>&<)>m manuals documentation <(>&<)> drawings as-built drawings, test certificates, o<(>&<)>m manuals
Tender For corrigendum : supply of led batten light (led tube light) (v2) (q2) , led luminaire (recessed luminaire) (ceiling light) conforming to is 10322 (part 5/section 2) (v4) (under bis scheme - ii) (q2) , led luminaire for road and street lights conforming to is 10322 (part 5/section 3) (v3) (under bis scheme - ii) (q2) , self ballasted led lamps (led bulb) (v3) conforming to is 16102 (part 2) (under bis scheme - ii) (q2) , miniature circuit breakers (mcb) for ac operation marked to is/iec 60898 (part 1) (q2) , moulded case circuit breakers (mccb) conforming to is/iec 60947 (part 2) (q3) , led bulkhead light (q3) , electrical plugs (v2) isi marked to is 1293 (q2) , elecric bells and accessories as per is 2268 (q3) , led garden light (v2) (q2) , non modular piano type domestic fan regulator conforming to is 11037 (q3) , plasticized pvc tapes with non-thermosetting adhesive for electrical purpose (v2) isi marked to is 7809 (part 3/ sec1) (q2)
Tender For repairing overhauling maintenance of electrical circuit and partial rewiring of residential quarters of rajendra and arjhula colonies of rajendra sub area of sohagpur area, secl
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - electrical switchyard; power house equipment, 420kv sf-6 circuit breaker bhel make; service provider
Tender For corrigendum : tender for re-conductoring of 3-ph. lt line from off size conductor to aaac 7/3.15 sq mm under 100 kva passu 250 kva sheela and prov. additional circuit under 250 kva sheela dtrs in dari section under electrical sub division -ii, hpsebl, dharamsal - tender for re- conductoring of 3 ph. lt line from off size conductor to aaac 7/3.15 sq mm under 100 kva passu & 250 kva sheela and prov. additional circuit under 250 kva sheela dtrs in dari section under electrical sub division -ii, hpsebl, dharamsala.
Tender For supply, installation, wiring and testing of specially designed 14 inch pole decorative light operated with 230v, 50hz supply wattage 10w to 15 w confirming to is:10322 (part-5sec1-2012 or latest with suitable wiring and protection system protected with 40a, 2/3 pole residual current circuit breaker of leakage current 30 ma and overload protection with mcb conforming to is:12640 part 2 or latest and iec 60898 part 1 or latest respectively and all electrical works shall be carried out in accordance with the provision of indian electricity act 2003 and indian electricity rules 1956 amended to date and all the safety codes and procedures outlined in the safety codes shall be complied with general and safety requirement shall be governed by is 13947 (pt i) 1993 and is:8623/1993, amended to date. [ warranty period: 30 months after the date of delivery ]