Tender For bid to ras supply of blood transfusion expendables c c - cryocyte bag final product vol 80 +/- 20% ml , wafers for sterile connecting device , disposable plastic infusion set for plasma/blood (pre-sterilised , pyrogen free) complete with airline and nylon filter alongwith airvent , dmso cell free , sterile for invivo use , radiation tags for gamma cell irradiator
Tender For supply of instrument spares in sugar mill - pressure gauge, complete s.s., bourdon tube type range- 0 to 30 psi, 3/8 or bsp bottom fitting, make waaree/radix. isi/iso standard a. dial size-4 , b. dial size- 6 isi/iso standard, c. dial size- 8 isi/iso standard, d. dial size- 10 isi/iso standard, pressure gauge, complete s.s., bourdon tube tipe range- 0 to 15 psi, 3/8 or bsp bottom fitting, isi/iso standard. a. dial size-4 , b. dial size- 6 isi/iso standard, c. dial size- 8 isi/iso standard, d. dial size- 10 isi/iso standard, pressure gauge, complete s.s., bourdon tube tipe range- 0 to 100 psi, 3/8 or bsp bottom fitting, isi/iso standard. a. dial size-4 , b. dial size- 6 isi/iso standard, c. dial size- 8 isi/iso standard, d. dial size- 10 isi/iso standard, pressure gauge, complete s.s., bourdon tube tipe range- 0 to 300 psi, 3/8 or bsp bottom fitting, isi/iso standard a. dial size-4 , a. dial size-4 isi/iso standard, b. dial size- 6 isi/iso standard, c. dial size- 8 isi/iso standard, d. dial size- 10 isi/iso standard, pressure gauge, complete s.s., bourdon tube tipe range- 0 to 600 psi, 3/8 or bsp bottom fitting, isi/iso standard a. dial size-4 , b. dial size- 6 isi/iso standard, c. dial size- 8 isi/iso standard, d. dial size- 10 isi/iso standard, pressure gauge, complete s.s., bourdon tube tipe range- 0 to 150 psi, 3/8 or bsp bottom fitting, isi/iso standard a. dial size-4 , b. dial size- 6 isi/iso standard, c. dial size- 8 isi/iso standard, d. dial size- 10 isi/iso standard, master gauge accuracy- 0.5%, dial size-150 mm, dial with antiparallax mirror, knife edge pointer isi/iso standard a. range- 0 to 30 psi, b. range- 0 to 100 psi isi/iso standard, c. range- 0 to 300 psi isi/iso standard, d. range- 0 to 600 psi isi/iso standard, master gauge accuracy- 0.5%, dial size-250 mm, dial with antiparallax mirror, knife edge pointer isi/iso standard a. range- 0 to 30 psi, b. range- 0 to 100 psi isi/iso standard, c. range- 0 to 300 psi isi/iso standard, d. range- 0 to 600 psi isi/iso standard, compound gauge, complete s.s., range- vacuum- 0 to 30 inch hg.. pressure- 0 to 30 psi., 3/8 or bsp bottom fitting. isi/iso standard . a. dial size- 4 , b. dial size- 6 isi/iso standard, vacuum gauge, complete s.s., bourdon tube tipe range- 0 to 30 inch hg. 3/8 or bsp bottom fitting, isi/iso standard. a. dial size- 4 , b. dial size- 6 isi/iso standard, dial type temperature gauge, complete s.s. mercury in s.s. tube, stem type. (size- 8 mm. dia x 300 mm. length.) range- 0 to 120 c isi/iso standard. a. dial size- 4 , b. dial size- 6 isi/iso standard, c. dial size- 8 isi/iso standard, dial type temperature gauge, complete s.s. mercury in s.s. tube, stem type. (size- 6 mm. dia x 450 mm. length.) range- 0 to 400 c isi/iso standard. a. dial size- 4 , b. dial size- 6 isi/iso standard, c. dial size- 8 isi/iso standard, dial type temperature gauge, complete s.s. mercury in s.s. tube, capillary type. capillary length-2 mtr., sensing dia 6 mm., range- 0 to 120 c isi/iso standard. a. dial size- 4 , b. dial size- 6 isi/iso standard, c. dial size- 8 isi/iso standard, dial type temperature gauge, complete s.s. mercury in s.s. tube, capillary type. capillary length-2 mtr., sensing dia 6 mm., range- 0 to 400 c isi/iso standard . a. dial size- 4 isi/iso standard, b. dial size- 6 isi/iso standard, c. dial size- 8 isi/iso standard, glass thermometer size- 14 isi/iso standard. a. alcohol filled, b. mercury filled. isi/iso standard, digitaltemperatureindicator, mounting size- 96 x 48 mm. isi/iso standard. a. pt-100 type, range- 0 to 200 c, resolution-0.1 c., b. k type, range- 0 to 600 c, resolution-0.1 c. isi/iso standard, c. j type, range- 0 to 600 c, resolution-0.1 c. isi/iso standard, digitaltemperatureindicator, mounting size- 96 x 96 mm. isi/iso standard. a. pt-100 type, range- 0 to 200 c, resolution-0.1 c., b. k type, range- 0 to 600 c, resolution-0.1 c. isi/iso standard, c. j type, range- 0 to 600 c, resolution-0.1 c. isi/iso standard, digitaltemperature co
Tender For supply of instrument spare and annual maintenance contract - circular charts:- i) cc-200 (fc-261)range 0-100, ii) 9/d/179/fc-241, range 0-600, iii) 9/d/147/s-8963, range 0-150, iv) 9/d/112/s-3452, range 0-30, disposable pen (red), temperature gauge dial size 6" (h guru) heavy duty with test certificate (mercury filed) :- i) range 0-150 c streight steam 6", ii) range- 0-150 c capillary type (3 meter) bulb length 10" copper/pvc, iii)range 0-300 c streight steam 6", iv) range 0-500 c streight steam 6", vacuum gauge dial size 6" range- 0-30 inch of hg/760 mm bottom feed connection 3/8" bsp, h guru heavy duty with test certificate., pressure gauge dial size 6" bottom feed connection size 3/8" or 1/2" bsp, h guru heavy duty with test certificate :- i) range 0-15 psi 01 kg/cm , ii) range 0-30 psi 02 kg/cm , iii) range 0-60 psi 04 kg/cm , iv) range 0-150 psi 10 kg/cm , v) range 0-300 psi 21 kg/cm , vi) range 0-1030 psi 42 kg/cm /70 kg/cm , pressure gauge, dial size 10" bottom feed connection size 1/2" bsp heavy duty with test certificate:- i) range 0-60 kg/cm h. guru with test certificate, ii) range 0-2 kg/cm2 h. guru with test certificate, pressure gauge for turbines heavy duty with test certificate:- i) 4" dial size side back connection %" bsp range 0-2 kg/cm , ii) 4" dial size side back connection %" bsp range 0-4 kg/cm , iii) 4" dial size side back connection %" bsp range 0-7 kg/cm , iv) 4" dial size side back connection %" bsp range 0-10 kg/cm , teflon coated compensating cable 2 core j type, compensating cable fg/ss 2-core k type, 4 digit digitaltemperatureindicator j & k typ , thermocouple sensor heavy duty:- i. 12" x 8 mm j/k type, ii. 8" x 8 mm j/ k type, iii. 6" x 6 mm j/k type, oil pocket ss 12", 6 digit digital event counter, proximity switch (magnetic sensor) pnp-nc sensing 8 mm,voltage 5-35 vdc, max load 300 ma, on/off pneumatic control valve flange type size- 1" to operate at air pressure 60-80 psi suitable for 20 kg/cm line pressure, on/off solenoid valve for pneumatic valve:- a) air filter " line size female thread, b) air filter with air regulator size 4", digitaltemperature controller (pid) j & k type, digital tachometer range 0-10000 rpm, 96 x 96 with magnetic sensor., steam flow indicator cum totalizer, drum level controller 4-20 ma input/output model no. 5296at (massibus make), dp transmitter 4-20 ma for boiler drum level, honybell make, positioner for drum level control valve, stroke counter for molasses tank, jumbo digital display with sensor, for juice and water tank, current and previous display size 4" x 4"., ma & mv source meter for temp. indicator calibration, pressure transmiter model tsc 01, range 0 to 40 bar, output 04-20 ma, accuracy 0.25% fs, pressure transmiter model ks-e-e-e b02u-m-v, range 0 to 2 bar, output 04-20 ma, supply 9-32 vdc, port g1/4e, syphon pipe s.s. 304 :- (i) u type, (ii) q type, pressure gauge, model en837-1, ss-316, dail size 6", bottom feed connection size 1/2" bsp, heavy duty with test certificate (tempsens make) :- i) range 0-6 kg/cm , ii) range 0-10 kg/cm , iii) range 0-21 kg/cm , iv) range 0-42 kg/cm , pid controller, size 96 96, model no. dc 1040, make honey bell, pressure recorder range, h-guru make, with test certificate (heany duty) with pipe stand mounted ", socket- ", size 10" :- (i) 0-1 kg./cm2, (ii) 0-2 kg./cm2, (iii) 0-10 kg./cm2, orifice with assembly (nipple), inlet pressure 21 kg/cm , outlet pressure 21 kg/cm , inlet temp. 350 c, outlet temp. 350 c, line size 4", drum level transmitter, range 400 to 400 in h2o, (make- honey bell), steam pressure transmitter, range 14.7 to 3000 psi, (make- honey bell), hade mounted thermocouple, length 450 mm, k-type duplex type, with test certificate (heany duty), signal isolator singal input 4-20ma, double output 4-20ma, repair & calibration work with amc super-heated wash water temp. controlling system- 01 no., d-super heated exhaust steam temp. controlling system- 01 no., temperature control system of transit
Tender For corrigendum : addition alteration and improvement of lt distribution system at dipr addition alteration in room for x ray irradiator behind nmr building at inmas and provision of patrolling path from probyn road to najafgarh drain under ge i rnd delhi - addition/alteration and improvement of lt distribution system at dipr, addition/alteration in room for x-ray irradiator behind nmr building at inmas and provision of patrolling path from probyn road to najafgarh drain under under ge(i) r&d delhi