Tender For bid to ras bid to ras supply of mechanical engineering and electrical engineering lab equipments - universal testing machine , rockwell cum brinell hardness tester , impact testing machine charpy and izod , digital torsion testing machie , digital spring testing machine , thermocouple , infrared thermometer , digital pyrometer , models of safety valve, blow off cock, steam stop valve, feed check valve, economizer , model of air compressor , model of lancashire boiler , model of nestler boiler , demonstration actual cut section model of two stroke single cylinder petrol engine , actual cut section model of four stroke single cylinder diesel engine , model of solex carburettor , model of amal carburettor , model of ignition system of an automobile , model of water cooling system of an automobile , model of lubrication system of ic engine , model of mpfi system , model of crdi system , single plate clutch , multi plate clutch unit , centrifugal cluth unit , cut section of synchromesh gear box , propeller shaft , cut section of differential assembly , model of mechanical brake , model of abs brake system , model of hydraulic brake system , ackerman steering gear mechanism , davison steering gear mechanism , model of rack and pinion steering gear , model of power steering gear or re-circulating type worm and wheel or other type of steering gear , model of ac pump , model of su pump , wheel balancing machine , automobile electric system , brake master cylinder , sliding mesh gear box , cut section model of 4 cylinder 4 stroke petrol engine , ac induction motor with vfd for motorizing already existing models in lab , metallurgical microscope , polishing machine , heat treatement furnace muffle surface , spark test apparatus , metallurgical cut off machine , standard prepared readymade samples and specimen with photographs , venturimeter and orificemeter apparatus , bernoulli theorm apparatus , darcy law apparatus , centrifugal pump test rig , pelton turbine model , francis turbine model , pressure measuring bench , go-no go thread plug gauge , go no go snap gauge , go no go ring gauge , cylinder rollers and spherical balls , slip gauges set , surface roughness tester , v block , tool maker microscope , auto collimator with stand , angle deckor with set of angle gauges , profile projector , screw thread micrometer , sine bar , radius gauge , comparator stand , angle plate , mechanical comparator with stand , clinometer , gear tooth vernier , thread measuring gauge , refrigeration cycle testing rig , digital anemometer , open hearth furnace with blower electric , anvil with stand , swage block , wood working lathe , spot welding set , electric metal cut off saw , hand lever shearing machine , hand hack saw frame , flat chiesel , carpentry vice , sharpening stone for carpentry tools , gas welding torch with tip , gas cutting torch with tip , oxygen regulator , hose pipe for acetylene , hose pipe for acetylene , pipe threading die set , mig welding set , tig welding set , mould making hand tools set hand rammer, lifter, trowels, shovels, vent wire, hand riddle, sprue pin , moulding flasks cope and drag , green moulding sand , parting off sand , crucible , bench grinder , shaper machine with standard accessories , slotting machine with standard accessories , horizontal milling machine arbor size 23mm and 32mm with standard accessories , grinder attachment for lathe , portable digital multimeter , portable digital wattmeter single phase , portable digital energy meter , ohms law verification kit , kirchhoffs law verification kit , portable digital ammeter ac , portable digital ammeter dc , portable digital voltmeter ac , portable digital voltmeter dc , resistance in series and parallel , hydrometer , rlc circuit trainer kit , dc shunt motor shunt generator set , dc shunt motor series generator set , dc motor alternator set , squirrel cage induction motor , slip ring induction motor , single phase capacitor start motor , scot connection tra
Tender For supply of low maintenance lead acid stationary secondary cell 2v 80 ah. with hard rubb er container with accessories inter cell connectors , nuts bolts and washers, micro poro us ceramic vent plug in dry and uncharged condition,conforming to rdso . specification ir s-s-88/2004 with latest amendments. a wall mounting type "tool board" of suitable material and prote cted against acid fumes shall be supplied along with set of 12 nos. each battery. the tool board shall com prise: i) one syringe for adding or taking out electrolyte from the cells. ii) one syringe type hydrometer of requisite range for measuring the specific gravity of electrolyte in the cells .this shall be provided with a gr aduated scale, on division of which representing at the most 0.005 unit of specific gravity with accuracy of calibration not less than 0.005 units of specific gravity. iii) one cell- testing %u2013voltmeter, 0 %u2013 3 v of accuracy, class 0.5 in accordance with is:1248-1968.the resistance of the voltmeter shall be 1000 oh ms/volt. iv) one thermometer with an appropriate scale for measuring temperature of electrolyte .one div ision of graduated scale of the thermometer shall represent at the most 1deg.c, the accuracy of calibration being not less than 0.5deg.c. [ warranty period: 48 months after the date of delivery ]
Tender For supply of low maintenance lead acid stationary secondary cell 2v 300 ah. with hard rub ber container with accessories inter cell connectors , nuts bolts and washers, micro por ous ceramic vent plug in dry and uncharged condition,conforming to rdso . specification i rs-s-88/2004 with latest amendments. a wall mounting type "tool board" of suitable material and prot ected against acid fumes shall be supplied along with set of 12 nos. each battery. the tool board shall co mprise: i) one syringe for adding or taking out electrolyte from the cells. ii) one syringe type hydrometer of requisite range for measuring the specific gravity of electrolyte in the cells .this shall be provided with a graduated scale, on division of which representing at the most 0.005 unit of specific gravity with accuracy of calibration not less than 0.005 units of specific gravity. iii) one cell- testing voltmeter, 0 to 3 v of accura cy, class 0.5 in accordance with is:1248-1968.the resistance of the voltmeter shall be 1000 ohms/volt. iv) one thermometer with an appropriate scale for measuring temperature of electrolyte .one division of grad uated scale of the thermometer shall represent at the most 1deg.c, the accuracy of calibration being not le ss than 0.5deg.c. [ warranty period: 48 months after the date of delivery ]
Tender For supply of low maintenance lead acid stationary secondary cell 2v 200 ah. with hard rub ber container with accessories inter cell connectors , nuts bolts and washers, micro por ous ceramic vent plug in dry and uncharged condition,conforming to rdso . specification i rs-s-88/2004 with latest amendments. a wall mounting type "tool board" of suitable material and prot ected against acid fumes shall be supplied along with set of 12 nos. each battery. the tool board shall co mprise: i) one syringe for adding or taking out electrolyte from the cells. ii) one syringe type hydrometer of requisite range for measuring the specific gravity of electrolyte in the cells .this shall be provided with a graduated scale, on division of which representing at the most 0.005 unit of specific gravity with accuracy of calibration not less than 0.005 units of specific gravity. iii) one cell- testing voltmeter, 0 to 3v of accura cy, class 0.5 in accordance with is:1248-1968.the resistance of the voltmeter shall be 1000 ohms/volt. iv) one thermometer with an appropriate scale for measuring temperature of electrolyte .one division of grad uated scale of the thermometer shall represent at the most 1deg.c, the accuracy of calibration being not le ss than 0.5deg.c. [ warranty period: 48 months after the date of delivery ]
Tender For supply of instruments as per nit documents-, lcr-series- resonant frequency impedance at resonance -quality factor and band width, , make: de tech, , to study the response curve of a series lcr circuit and determine its (a) resonant frequency, (b) impedance at resonance, (c) quality factor and (d) band width, , to measure the voltage across the inductance (l), capacitance (c) & resistance (r) of a series lcr circuit for different frequencies of the input voltages with the help of an ac millivoltmeter & hence 1) to study the variation of impedence of l & c with frequency of the impressed voltage, 2) to draw the resonance curve of the series lcr circuit & to determine the q factor of the circult., , complete with audio oscillator sine wave 0-10v p-p 10khz with digital frequency counter, digital ac voltmeter, digital ac ammeter or voltmeter, digital frequency counter, different values of l, c & r. complete in all respect with detalled manual., , multimeter, digital. low cost heavy duty reliable for student use, , make: imported, , to measure v, i, ohms, transistor hfe, continuity check, diode check. low cost student model., , digital multimeter, lcr model:451, , peak hold facility, , display: 3-1/2 digital 1999 counts backlit lcd low battery and overload indication confirms to iec1010 standards, , auto power off, , dc voltage: 0-200mv/2v/20v/200v/1000v accuracy: +0.5%, , ac voltage: 0-200mv/2v/20v/200v/750v accuracy: 0.8%, , dc current: 0-2ma/20ma/200ma/20a. accuracy: 0.8%, , ac current: 0-2ma/20ma/200ma/20a. accuracy: 1.0%, , resistance: 0-200/2k/20k/200k/2m/20m/2000m.ohms accuracy: 0.8%, , capacitance: 0.20nf/200nf/2uf/20uf/200uf accuracy: 2.5%, , frequency: 0-2k/20k/200k/2m/10mhz accuracy: 1.0%, , inductance: 0-2m/20m/200m/2/20h accuracy: 2.5%, , temperature: -40c-1000c accuracy: 1.0%, , diode test, transistor test and audible continuity test facility., , apparatus for determining variation of thermo emf of, , thermocouple using temperature difference of two junctions, , make: de tech model: dt-temf, , potentiometer with jokey[10 no wire] power supplies:, , dc supply ic regulated +2/4v dc, 500ma. meters: digital voltmeter dc (dual range) digital ammeter dc (dual range) digital galvanometer, , as null detector components are mounted on the panels are: 2 dial decade resistor box on board., , salient features:, , front panel built with high class insulated printed circuit board sheet with well printed circuits and symbols., , instruction manual., , connections are brought out through 4mm colored sockets., , patch cords 4mm., , the trainer is housed in abs plastic cabinet. size of the trainer set 12"x10" accessories with trainer:, , 10 wire potentiometer electrical kettle constantan thermocouple glass beaker thermometer, , set up to determine the co-efficient of thermal expansion of a metal by optical lever & traveling microscope., , make: de tech, , complete experimental set. 1.pullinger's apparatus, , two 1 meter long concentric pipes fitted on a wooden bracket with metal base. outer pipe is covered with asbestos rope & has arrangement for thermometer holes & also steam inlet & outlet at upper & lower ends. supplied with 1 meter long aluminum & steel rods of 1/4" dia. to be inserted inside inner tube., , study of vi and power curves of solar cells, and find maximum power point and efficiency, , to draw v and i characteristics of solar cell and find maximum power and efficiency., , the apparatus consists of optical bench with uprights (length: 1 mtr), cell mounted, meters are fitted on panel with power supply and lamp house with power supply., , measurement of stefans constant using black body, , radiation., , make: de tech model: dt-sbbr, , measurement of stefans constant using black body radiation., , complete with stefans conatant apparatus, very high sensitive light spot galvanometer with sensitivity control, high quality thermocouple.3 it cu boller, rubber tube, electrical heater w
Tender For corrigendum : supply of measuring instruments for emd-1 to 8 at wtps. - digital infrared thermometer (type: portable non-contact type thermometer, range: -40 to 800 deg.centigrade, sighting: laser guided, accuracy: +/- 0.5 deg. centigrade), analog multi range insulation tester.hand driven type,voltage range-250v/500v/1000v., portable infrared thermal imaging camera with laser pointer., digital megger (insulation tester) dual voltage 500/1000 v 0 to 2000 megaohms resolution of 1 m? weght: 500 gm approx., digital vernier calipers size - 0-300 mm mitutoyo make, digital multimeter 4.1/2 digit (true rms), digital clamp on meter lcd display with backlight, 3-3/4 digit., digital ma clamp on meter, digital micro ohm meter model, clamp type digital earth resistance meter, digital insulation resistance measuring equipment. max. range: 1 tera ohm, selectable voltage range: 250/500/1000/2500/5000 v, portable, analog motor checker, ac ammeter 0-150a 4-20ma input , class - 1.5, 72 x 72 mm, ac ammeter 0-100a 4-20ma input , class - 1.5, 72 x 72 mm, ac ammeter 0-50a, 4-20 ma, class -1.5 ,72x72 mm,0- 90 deg scale, ammeter a.c range: 0-200 amp.(moving iron) 4 - 20 ma accuracy: 1.5 dimention: 72x72 mm (panel mounted), a-meter : range 0 to 250 - 1500a ac, moving coil, ctr 250/1 a, 1.5, mounting panel, size 96x96, scale 240 deg, is -1248, make ae., ac ammeter 0-150a 150/1, class - 1.5, 72 x 72 mm, ac ammeter 0-200a 200/1, class - 1.5, 72 x 72 mm, a.c.ammeter moving coil ac rectifier type ct operated (w/o ct) range 0-150 a ctr 150/1a size:96x96 mm , 240 deg circular scale,flush panel mounting, ac ammeter 0-100a, 100/1, class -1.5 ,96x96 mm, 0-20-40-60-80-100-600a, analog ammeter ctr 50/1 range 0-50-300, ac ammeter range 0-200 amp. ct operated ctr 200/1 a, 96x96, ac ammeter 0-30a, 30/5, class - ,96x96 mm,0- 90 deg scale, ac ammeter 0-75a, 75/5, 96x96 mm,0- 90 deg scale, ac voltmeter 0-300v, class -1.5 , 96x96 mm,0- 90 deg scale, ac volt meter range 0-500 volts 96x96 mm2 moving iron type 90 deg., accuracy class +/- 1 percentage, type sif 96, kew make, volt meter, range-0 to 500v, ptr:415/110v, size:96*96mm., dc ammeter range 0-500 amp, 96x96 mm2, moving coil type to be connected with 75 mv shunt (without shunt), dc center zero ammeter scale 200-0-200 a dc, 96 x 96 sq.mm switchboard flush panel mounting moving coil to be operated with an external shunt of 75 mv drop, 90 deg. scale (without shunt), accuracy class +/- 1 percentage type, dc ammeter 0-400a, 60 mv shunt, class -1.5 ,72x72 mm,0- 90 deg scale, dc ammeter 0-100a, 75 mv ext.shunt, class -1.0 ,96x96 mm,0- 90 deg scale, dc voltmeter 300-0-300v, class -1.0 , 96x96 mm,0- 90 deg scale, dc voltmeter 0-50v, class -1.5 , 72x72 mm,0- 90 deg scale, ac ammeter 0-630a, 630/1, class -1.0 ,96x96 mm,0- 90 deg scale, ac ammeter 0-4000a, 4000/1, class -1.0 ,96x96 mm,0- 90 deg scale, dc voltmeter range 0-100kv 400micro amp, analog ammeter ctr 400/1 range 0-400, ae make dc amp meter,moving coil type,range:-0 to 1500 milli amp,fsd:-0 to 1 milli amp for 2.25 vdc,accuracy class:-1.5,flush mounting type,240 degree circular scale.size:-96x96 mm