Web Analytics Made Easy - StatCounter

Digital Timer Tenders

Get complete information related to latest Digital Timer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Digital Timer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Digital Timer Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :40435390 Due date: 13 Jun, 202513 Jun, 2025 37.15 Lacs
Tender For corrigendum : maintenance of water supply system - operation of 10mld pressure filter plant including supply of chemicals to treat raw water at cuelim, cansaulim, goa. (retender 2nd call) - operation of 10mld pressure filter plant to carryout day to day activities of treatment of raw water, with suitable man power for attending and operation of valves , suction pump, blower pump, back washing of filter bed , dosing pumps, agitating pumps, chlorine and alum dosing pumps, etc. chemical mixing with water, in chemical dosing & treating to get potable water as per who norms. keeping of all the records in respect of raw water and treated water quantity and quality aspect. recording flow meter reading , etc. complete. the plant operating man power/staff should be arranged round the clock in shift as per the directions of engineer -incharge., supply at store/site of work including transportation loading & unloading etc of alumina ferric containing 16% of al2o3 content as per is 299/2012 grade -iv packed in hdpe bags of uniform weight suitable for water treatment plant., supply at store/site of work including , transportation , loading & unloading,freight insurance etc., of sodium hypochlorite containing 6% to 8% of chlorine concentration or as required, suitable for water treatment plant, filled in hdpe can of uniform weight, including re-transporting empty hdpe cans from departmental store/site to refilling plant etc., complete.as directed by engineer in charge.

corporations/Associations/Others

CTN :40527283 Due date: 12 Jun, 202512 Jun, 2025 33.58 Lacs
Tender For dg - waluj industrial area...m and r to cwss, waluj providing photo water meter reading system through mobile application and distribution of water bills, notices and consumer services at waluj industrial area.

corporations/Associations/Others

CTN :40546569 Due date: 13 Jun, 202513 Jun, 2025 14.64 Lacs
Tender For m and r to cwss, waluj .providing photo meter reading system through mobile application an distribution of water bills notices and consumer services for chhatrapati sambhajinagar, chikalthana and shendra industrial area.sambhajinagar, chikalthana and

Central Government And Public Sector

CTN :40511156 Due date: 16 Jun, 202516 Jun, 2025 NA
Tender For supply of " digital timer thumb wheel type. digital timer of size 72x72mm with the fol lowing features: a)operating source voltage 110v ac or 220v ac +/- 10%. b)thumb wheel set point to 0 to 999 secs. c)digital display of elapse time. d)1no instantaneous & 1no del ayed contact. the contact rating shall not be less than 1a. ]

CTN :40471484 Due date: 03 Jun, 202503 Jun, 2025 NA
Tender For supply of digital timer (q3)

State Government

CTN :40398381 Due date: 13 Jun, 202513 Jun, 2025 NA
Tender For empanelment of agencies for supply of laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoridemeter: ph/ise benchtop meter with electrode stable, universal power adapter, literature, pc cable, meter test certificate electrode: ionplus fluoride and nitrate combination ion selective electrode, 1m cable, waterproof bnc benchtop ion meter (ise) along with fluoride, nitrate #electrode range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 relative accuracy 0.002 calibration points up to 5 calibration editing yes #mv/ rmv orp range 2500.0 mv resolution 0.1 relative accuracy 0.2 mv or 0.05 % of reading whichever is greater eh orp mode yes ise range 0 to 19999 resolution up to 3 significant digits relative accuracy 0.2 mv or 0.05 % of reading whichever is greater units ppm, m, mg/l, %, ppb, none calibration points up to 5 calibration editing yes calibration features timed end point, linear point to point, non-linear selectable auto-blank, low concentration range stability #temperature range -5 to 105 c, 23 to 221 f resolution 0.1 relative accuracy 0.1 offset calibration 1-point datalogging memory 2000 with time and date stamp log function manual, ready (include auto-read ), timed log edit delete individual points, group of points or all inputs ph electrode bnc, reference pin atc probe 8-pin mini-din #output rs232, usb power ac adapter included universal, 100-240 vac battery power optional 4 aas battery life 800 hrs, fluoride electrode of ion metersame make that of the ion meter, manifold filtration assembly* wide range of pumps and filtration flasks * high quality components * easily exchangeable elements *maintenance-free * low noise * added filters for enhanced pump longevity * filtration base with silicon stopper, cap & aluminium clamp connecting silicon tube technical specification for filtration flask set # high-pressure resistant tube # fiberglass filter membranes (47mm / 0.1 m) # ptfe disc filter #normal liquid filtration * specification for filtration glass set #suction bottle capacity(ml) 1000 ml # filter diameter(mm) 47/50 mm # * specification for filter flask * material: statinless steel 304, capacity: 300 ml (100 ml each) [ unit should consist of 3 flask so that 3 sample can be filtered simultanelously without any issue] # effective filtration area(cm2) = 9.6 cm2, outlet connector(mm) = 8 mm * specification for vaccum flask: #flow rate of the pump(l/min) = 17 l/minultimate vacuum(mbar) = 150 mbar # oil free, maintainance free, built in thermal protection to shut off when over heated., auto cut heater for distill water plant so that when water level decreases the heater is switch off automatically, voltage stabilizer capacity- 3 kva servo stabilizer 5 star rating, heating mantle (single station) should have digital energy regulator with multiple step power regulation automatic spill detection and saftey shutdown in built precision temperature control technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 420 degree celcius. accuracy: plus minus 1.0 degree celcius, power consumption : 150 w, heating mantle (combined unit) material of construction heating block: made with grade epoxy painted chemical resistant coating, aluminum block with 6 thermo wells for processing 6 different samples at a time. #racks: ss 316 # glassware: teflon coated # temperature range ambient + 10 deg c to 450 deg c # stability of temperature better than 0.5 deg c # controller consist of digital read out of temperature and time with 4 programmable ramps for each method. # number of programmable methods 20 numbers. # heating powers 1000w # heating position minimum 6 position # digestion time range -1 to 999 minutes # the system should have facility of acoustic signal at the end of completion of cycle to notify the operator. # the thermal digestion unit should have high thermal homogeneity # the setup should have small footprint. # th

corporations/Associations/Others

CTN :40420978 Due date: 17 Jun, 202517 Jun, 2025 3.27 Lacs
Tender For procurement of lab instruments for chemical lab of ogcd, dtps, htps, kasimpur - sension5 portable conductivity meter specification range:#conductivity s/cm 0 to 19.99; 200 to 1999#conductivity ms/cm 2 to 19.99; 20 to 199.9#tds: 0 to 50,000 mg/l as nacl salinity: 0 to 42 g/l (ppt)#temperature: -10.0 to 105.0 c#resolution:#conductivity 0.01; 1.0#conductivity ms/cm 0.01; 0.1#tds: 0 .00-199.9 mg/l 0.1mg/l 2 00-1999 mg/l 1 mg/l 2 .00 -19.99 g/l 0.01 g/l 2 0-50 g/l 0.1g/l #salinity: 0.1 g/l (ppt)#temperature: 0.1 c#accuracy:#conductivity: 0.5% in the first 3 ranges, 1% at highest range #td of full scale #salinity: 0.1 ppt (-2 to 35 c) #temperature: 0.1 c# , make-hach, ph meter probe (ph meter sension ph3) cat no-lzw5010t.92.0002 make hachdetails in photograph enclosed in tender document, manual sieves shaker (with sieves set - mesh size-50,+100,+200) any standard make details in photograph enclosed in tender document, centrifugal machine for oil testing, any standard maketube capacity:no.12-24:size 15 mlshould have a digital timerbody should be made of strong fabricated & corrosion resistant steel.control panel- for start/stop switch, dynamic brakes, step less speed regulator with zero start switch & speed indicator with timer and protective fuses.door interlock.maintenance free brushless drive motor with exact speed preselection and display. speed range 100 to3000 rpm and above, accuracy 1 rpm. details in photograph enclosed in tender document, orset appratus (complete set), any standard make details in photograph enclosed in tender document, ph 2700 ph meter specification #ph range -2.000 to 20.000 ph #resolution 0.1 / 0.01 / 0.001 ph #accuracy 0.002 ph + 1 lsd #cal. points up to 6 preset or 5 custom #buffer sets usa, nist, din, user 1, user 2, custom #or range 2000.0 mv #rel. mv range 2000.0 mv on 0.1 mv# accuracy 0.2 mv #temperature,range (meter) 0.0 to 100.0 c / 32.0 to 212.0 f #resolution 0.1 c / 0.1 f #accuracy 0.3 c / 0.5 f #compensation atc / mtc #power requirements 9 v dc adapter, 1.3 a (100/240 vac, smps)# make- eutech

CTN :40359811 Due date: 23 May, 202523 May, 2025 NA
Tender For quotation for 18-volt led street light driver, 35-volt led street lightk, 70-volt led street light driver, three phase contactor of 40-a, digital timer, 32-a m.c.b.s.p. self, 24-volt led street light

CTN :40329670 Due date: 02 Jun, 202502 Jun, 2025 NA
Tender For supply, fitment and rewiring of baking oven and its lt defective panel at els/bk sc. (1) selec tc203ax digital temperature controller motion controller (black, for ps33 digit single display temperature controller (tc: j, k, t, r, s/ rtd: pt100) sensor input, on-off/auto-tune pid control, single set point, 10a relay/12v ssr control output, 72 mm x 72 mm size, panel mount, 90 to 270v ac/dc supply volt age, qty- 01nos. (2) immersion coil 2000 watt, qty-4 nos (3) mcb 63-amp 3-pole c curve make- l&t and havells, siemens, anchor, qty-3 nos, (4) hrc fuse, 63a, 415v make-l&t, siemens and havells, anchor, qt y-8 nos. (5) hrc fuse, 32a, 415v make- l&t, siemens and havells, anchor, qty-5 nos. (6) dmc kit kat fus e 63 amp 415 volt make- l&t, siemens and havells, anchor, qty-5 nos (7) dmc kit kat fuse 23 amp 415 v olt make-l&t, siemens and havells, anchor, qty-5 nos. (8) l&t, siemens and havells, anchor, power cont actor 70 amp mnx 70,qty-1 nos. (9) minilec vsp3/415 vac phase failure relay ,qty-1 nos. (10) siem ens and havells, anchor, l&t mnx-a1 add-on bl.2no+2nc 4 poles contactor, qty-1 nos. (11) control tra nsformer input-415v output-240v 500kva , make-l&t /siemens/havells,anchor, qty-01nos. (12) copper wire 1.5mm make make- l&t /siemens/havells/anchor, qty-60 mtr. (13) siemens/havells/anchor, salzer (l&t) 10 a voltmeter selector switch (vss) (voltage between phase with off) (yellow) qty-1 nos. (14)cop per wire 2mm make make- l&t /siemens/havells/anchor, qty-80 mtr. (15)push button (green and red) wi th 2no 2nc three phase qty-4 nos. (16) panel indicator (color- red, yellow, blue) qty-4 nos. (17) siemens /havells/anchor, salzer (l&t) 10 a ammeter selector switch (line currents with off) (yellow) qty-1 nos. (18) siemens/havells/anchor, salzer (l&t) 10 a 3 pole 2 way auto-manual 10 a cam operated rotary swi tch (yellow) qty-1 nos. (19)thermocouple temperature control 0-400 c sensor qty-1 nos. (20) analog am pere meter ac (0-200 a) make-ae , digital timer for panel make-l&t, siemens and havells, anchor, qty-1 n os. (21) digital timer for panel make-l&t, siemens and havells, anchor, qty-1 nos. (22) analog volt meter ac (0-500 v). make- ae,l&t, siemens and havells, anchor, qty-1nos. [ warranty period: 30 months after the date of delivery ]

Central Government/Public Sector

CTN :40309101 Due date: 22 May, 202522 May, 2025 NA
Tender For supply of semiautomated biochemistry analyzer , 3 parts hematology analyzer , urine analyzer , digital hemoglobinometer , glucometer with 50 free strips , computer with ups , printer , microscope _ binocular _led fm , rotor _ shaker 12 or 18 tubes , centrifuge _ 16 tube , refrigerator , needle syringe destroyer , micropipettes 100 _ 1000 microlitre_one millionth of a litre. , micropipettes 10 _100 microlitre_one millionth of a litre. , micropipettes 5 _ 50 microlitre one millionth of a litre. , micropipettes 250 microlitre _ one millionth of a litre. _fixed , digital timer or alarm clock , air conditioner with stabilizer , micro esr tube , blood collection tubes , bar code scanner
 Loading, Please wait...

Connect us via What's Up