Get complete information related to latest Ding Dong Bell Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ding Dong Bell Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ding Dong Bell Tenders.
Tender For supply of time delay relay analog timer 22.5 mm din rail operating voltage 24 volt ac to 440 volt ac, 12 volt dc to 220 volt dc, contact-5a, time delay 0.5 sec. to 6.0 hours . make -: selec, techno, eapl, l&t, multispan or similar. [ warranty period: 12 months after the date of delivery][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For regular operation and maintenance of street lights (with material) at all industrial areas under riico ranpur kota(for 2 years) - regular operation and maintenance of high mast light in ranpur , kota including supply and replacing the required material and labour etc. complete as per the following terms and conditions:- i at any moment a minimum of 90% of total fixture must be in order. the defective fixture must be repaired within 3 days, falling which deduction for number of light which are not functioning in the industrial area shall be made at one time of the rate (accordingly deduction for lights which are not functioning becomes two times of the rates from total payment due for total number of lights whose operation and maintenance was awarded to the contractor ). ii contractor shall arrange at his cost for put on & off the street light fixture at appropriate time regularly as per instructions of engineer-in charge. a register shall be maintained at riico/association office and complaint lodged must be attended by contractor within 24 hours. the person deputed by contractor shall attend the riico/association office daily and comply the instructions and attend complaints regularly. iii contractor will have to employ trained and qualified electricians for the work. iv corporation shall not be responsible for any kind of accident during execution of work. v contractor will be responsible for safety and security of fixtures and all concerned materials. vi contractor will be responsible for arrangement of all t&p required for the work vii cost of all labour and material like lamp / balllast wire etc. will be born by contractor. all material required for the work shall not be below the category-ii of concerned bsr item. contractor has to repair and maintenance of fixture with material in all cases like short circuit, phase to phase of jvvnl line etc. viii no extra payment will be made for fixing/removal of extra/existing fixture in the industrial area. ix contractor will be responsible for timely collection and deposition of electric bills of areas in each month. in case of delay in payment and jvvnl impose surcharge for delay payment the same will be recovered from the running bill fo the contractor. payment of electricity bill will be made by riico. x contractor will be responsible for rebate of timer provided by jvvnl. hence contractor will maintain the on/off system by timer properly. in case no rebate is provided by jvvnl due to failure of timer then rebate will be deducted from contractor payment. xi contractor will be responsible for any theft of electricity through poles and he will make necessary arrangements for this. in case of any theft is found suitable penalty will be imposed on the contractor. xii contractor will maintain cubical panel board and assessories fitted in it. in case of any fault repair/replace of material will be done by the contractor at his own cost. no extra payment will be made on behalf of material. xiii contractor has to keep ready total fixtures. in case of fault of fixture a penalty of rs.100/- per fixture per day will be imposed on the contractor., regular operation and maintenance of street light fixtures hpsv/ hpmv (70w/150w) in ranpur, kota including supply and replacing the required material and labour etc. complete as per the following terms and conditions:- i at any moment a minimum of 90% of total fixture must be in order. the defective fixture must be repaired within 3 days, falling which deduction for number of light which are not functioning in the industrial area shall be made at one time of the rate (accordingly deduction for lights which are not functioning becomes two times of the rates from total payment due for total number of lights whose operation and maintenance was awarded to the contractor ). ii contractor shall arrange at his cost for put on & off the street light fixture at appropriate time regularly as per instructions of engineer-in charge. a register sh
Tender For supply of mpcb gv2 p02 0 16 0 25a , mpcb gv2 p04 rat 0 4 0 63amp i c 0922557 , mpcb gv2 p05 rat 0 63 1 0ampi c 0922558 , mpcb gv2 p06 i c 0922559 rat 1 0 1 6a , mpcb gv2 po7 telemechanique 1 6a 2 5a , te make mpcb ty gv2 p08 range 2 5 4 a , mpcb gv2 p10 i c 0922562 rat 4 6a , te make mpcb ty gv2 p14 range 6a to 10a , mpcb gv2 p16 i c 0922564 rat 9 0 14 0a , mpcb gv2 p20 rat 13 18amp i c 0922565 , mpcb gv2 p21 17 23a make telemechani , mpcb gv7 rs40 i c 0922522 750 v 40amp , busbar for mpcb breaker ty gv2 g354 63a , zelio input 30 no output 15 no 240vac , joystick xd2 pa22 , joystick xd2 pa24 , magnetic coil contactor lx1 fg 240 50hz , aux cont 3nc 2no 240vac cad32u7 , add on block 1c 1o type gvae1 , on delay aux contact block ty la2 ot07 , off delay aux contact blaock ty la3 or2 , contact block additional zbe 101 1 no , contact block additional zbe 102 1 nf , lt2 spoom thermister protection relay , on delay add on timer block , 3pole contactor lc1 d80p7 80a ic 1122518
Tender For corrigendum : supply of led luminaire for floodlight conforming to is 10322 (part 5/section 5) (v3) (under bis scheme - ii) (q2) , led batten light (led tube light) (v2) (q2) , led luminaire for road and street lights conforming to is 10322 (part 5/section 3) (v3) (under bis scheme - ii) (q2) , ac encloosure box modular with mcb 20 or 25 amp , capacitor 4 mfd , condenser 2.5 mfd , electric angle or batten holder for bulb , electric bell push 6 amp , electric dingdongbell , electric pendent holder for bulb , electric plug top 16 amp , electric plug top 20 amp 3 amp round , electric socket 06 amp , electric socket 16 amp , electric socket 20 amp , electric switch 06 amp , electric switch 16 amp , electronic fan regulator , led batten 10 w 2 feet long mirror light , led batten 18 w 4 feet long with complete fitting , led bulb 12w rechargable , led bulb 9w rechargable , led inverter type tube light fitting 20w , led lamp 12 watt , led lamp 14 watt , led lamp 18 watt , led lamp 5 watt , led lamp 6 or 7 watt , led lamp 9 watt , led post top lamp with complete fitting 15 or 20 watt , led surface mounting of size 600 x 600mm of 36 watt , mcb 06 amp single pole , mcb 10 amp single pole , mcb 16 amp double pole , mcb 16 amp single pole , mcb 20 amp single pole , mcb 25 amp single pole , mcb 32 amp single pole , mcb 32 amp double pole , mcb 40 amp double pole , mcb 63 amp double pole , mccb 100 amp 4p 25 ka , mccb 125 amp 4p 25 ka , mccb 160 amp 4p 25 ka , mccb 200 amp 4p 25 ka , mccb 200 amp 4p 36 ka , mccb 250 amp 4p 25 ka , mccb 250 amp 4p 36 ka , mccb 320 amp 4p 36 ka , mccb 400 amp 4p 36 ka , out door led bulk head 10 or 18 watt , pvc cable 1.5 sqmm single core copper conductor , pvc cable 2.5 sqmm single core copper conductor , pvc cable 4 sqmm single core copper conductor , pvc tape insulation 20mm wide 25 mtrs long , tape insulation 25mm wide 25 mtrs long //bid details 2 / 51