Get complete information related to latest Dipstick Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Dipstick Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Dipstick Tenders.
Tender For supply of dipstick with cap & chain elgi part no.-070407170, filter over flow dcm part no.-070407080 , washer copper strain dcm part no.-070406770 for memu [ warranty period: 30 months after the date of delivery ] ]
Tender For spare parts of scania - hose part no 283136, dust cover part no 190335, seal ring part no 214309, seal ring part no 164900, hose part no 811195, hose part no 188283, control part no 1104198, dash board lock part no nk, head light assy part no 389483, cover part no 310518, plate scania part no 352140, rear toe lock part no nk, lmg bracket part no nk, screw m8x16 part no 808293, oil dipstick (eng ) part no 271225, intermediate part part no 219516, filler tube part no 257754, drain cock (tap) part no 228491, hollow screw part no 17146, hollow screw part no 17384, fuel tank part no 292781, hollow union part no 377424, lock ring part no 804787, piston ring part no 244186, plug part no 244465, plug part no 129386, drive part no 389606/389672, piston part no 367124, disk, outer part no 194428, disc, inner part no 194429, lock ring part no 804793, switch part no 328655, cover part no 317203, intermediate piece part no 254757, regul. valve, front part no 390485, regul. valve, rear part no 390487, elbow connection part no 161901, temperature monitor part no 334383, shim 0, 5 mm part no 274416, drain tube part no 224266, solenoid valve part no 1115802(350127), elbow connector part no 208405, reducing nipple part no 244439, sensor(speed) part no 284154, oil cooler part no 391173, connector part no 275052, journal part no 264043, lubricator part no 806311, three-way nipple part no 248351
Tender For running maintenance of plc system - running preventive and breakdown maintenance of plc control system with electrical drives all control and instrumentation system of ash handling , replacement new erection of impulse line , replacement new erection of instrument fitting adopter nut tails elbow connector etc , overhauling b 501 and b 601 ss cock valve , overhauling repairing of junction boxes , servicing recalibration erection of fuzi yokogava rosemount etc transmitters , overhauling and recalibration new erection of digital indicators , overhauling and recalibration erection of flow meter conductivity meter , complete overhauling erection of level switches , replacement of pressure switch gauge vibration switch , removal testing erection commissioning calibration of temp gauges switches thermocouple , replacement erection overhauling cleaning of union isolating valveforged body valve , blowing of tapping points of different pressure transmitters switches , fabrication repairing of instruments plateform , laying patrolling of instrumentation cable , servicing and maintenance of air conditioner , cleaning of control room plc system , repairing of ups , service replacement of faulty butterfly valves along with act , servicing replacement of faulty diaphragm type valves , changing spindle gland of root valves , cleaning blowing by air of impulse lines , attend leakage from steam water air line , replace gauges switches of pressure temp , testing caliberation of pressure gauges , testing calibration of pressure switches , testing calibration of temp gauges , testing calibration of temp switches , replacement of thermocouples , cleaning servicing of terminal block in compressor house swas system , changing of ss root valves , servicing of 10mm hp lp 3way manifold valves , replace of 10mm hp lp 3way mfold valves , removal choking replace of impulse line , erection replacement of pvc armored compensate cable , replacement of universal digital indicator , servicing replacement of faulty 4way valve with actuator , replacement remounting of smps 24 v dc , dismantling replacement of combination timerof compressor , servicing of sampling cooler dhx18 sco2 , servicing of sampling cooler dhx12 sco2 , servicing of sampling cooler dhx06 sco1 , miscellaneous mechanical febrication , maintenance of actuator of butterfly valve , maintenance and upkeep of terminal box of motor of actuators in cw pump , maintenance re erection of butterfly valve actuator motor , revisioning and upkeep of marp dcs panel , revisioning testing of various type of switches of local control panel , maintenance revisioning upkeep and testing of 415 v power supply module , maintenance upkeep and repair of junction box of butterfly valve , servicing of mov motors actuators and limit switch assembly , checking cleaning and cable dressing mov motor , overhauling cleaning reconditioning of various size batteries , load test once in six months for various size battery of ups installed for 5x200mw , replacement of damaged switches mcb in acdb panel , cleaning painting of the wooden battery stands , maintenance of window type split type ac , gas charging of ac , rewinding of burnt fan motor
Tender For procurement of spare parts for mm scorpio s5 material for vehicles of asphalt garage under ex eng tr city - glow plug scorpio s5, oil level dipstick assembly scorpio s5, pipe leak off lxcdri scorpio s5, filler and vent pipe assy scorpio s5, pipe assy filler def scorpio s5, fuel line assy return to tank scorpio s5, front suspension bushing kit scorpio s5, ball joint upper control arm scorpio s5, ball joint lower control arm scorpio s5, mc assy with clutch npl resrvoir scorpio s5, inner ball joint(tie rod inner) scorpio s5, outer ball joint(tie rod outer) scorpio s5, link stabiliser bar front rh scorpio s5, link stabilizer bar front lh scorpio s5, link stab bar rear rh scorpio s5, link stab bar rear lh scorpio s5, reg elect rr door window lh scorpio s5, reg elect frt door window lh scorpio s5, power steering pump assy scorpio s5, compressor assy scorpio s5, condenser assy mhawk scorpio s5
Tender For corrigendum : repair and comprehensive maintenance of swimming pool plant and equipments fire fighting system at af stn nal under ge (af) nal - comprehensive annual maintenance of swimming pool comprises of the following equipments complete all as specified and directed.(a) pumping sets of capacity 3.5 hp - 05 nos (01 as standby) (b) pressure filter of filtering capacity 50 cum/hr - 04 nos (01 as standby)(c) dosing pump - 02 nos (one for chlorination and one for soda ash)(d) electrical panel board consisting of starters of suitable rating complete.note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit swimming pool once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of swimming pool.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account. (iii) cleaning all swimming pool building inside, plant room, equipments including surrounding area of the buildings. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of 3.5hp / 3.26 kw capacity and all other connected items., comprehensive annual maintenance of fire fighting system in sekhon hall , new tech flight, sre and new atc of the following equipments complete all as specified and directed.(a) main fire pump with centrifugal motor of existing capacity- 04 nos (b) jockey fire pump with electric motor of existing capacity - 04 nos (c) makeup fire pump- 04 nos(d) dg fire pump with engine - 04 nos note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit fire fighting installation in sekhon hall , new tech flight and new atc once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of installation.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account.(iii) cleaning all fire fighting installation buildings (sekhon hall , new tech flight and new atc) inside, plant room,equipments including surrounding area of the building. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of all existing capacity and all other connected items., s&f in repair pressure pump limit switch of capacity 1psi to 4 psi and 230 volt as per existing make and model fixed on pressure booster line complete all as specified and directed., supply, installation, testing and commissioning in repair of detectors complying with and type certified to en-45 addressable type multi sensor detector with heat and smoke combination with base with self built intelligence as per is:11360 (for annexes) complete all as specified and directed., supply, installation, testing and commissioning in repair of addressable manual call point / pill station resettable type with base complete all as specified and directed, supply, installation, testing and commissioning in repair of fire alarm sounder/siren electronic type horizontal single stage continuous type normal operation for atleast 50 minutes with sound level 65 db to 120 db measured at 1.5 mtr with sound output variation +5 db 500 mtr complete all as specified and directed, supply and fixing in repair addressable monitor module for activating the sirens complete all as specified and directed, taking out old unserviceable hose box by cutting and welding and s&f hose box made of 18 gauge ms sheet 800mmx 600 mm x 250 mm with double door with 4 mm thick glasses and door frame made of 16 gauge ms sheet for keeping 2 nos hose pipe of length 15 mtr each branch pipe nozzle coupling etc and painted fire red out side and brilliant white inside yard complete all as specified and dire